Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System

In the current distribution network, photovoltaic, wind power, energy storage, and other distributed energy are widely connected, and the proportion of generalized DC load is rapidly increasing. With the development of power electronics technology, using multi-port power electronic transformer (PET)...

Full description

Bibliographic Details
Main Authors: Xinxing Xu, Wentao Huang, Yan Hu, Nengling Tai, Yaming Ji, Ning Xie
Format: Article
Language:English
Published: Frontiers Media S.A. 2021-09-01
Series:Frontiers in Energy Research
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fenrg.2021.721385/full
_version_ 1818609597114482688
author Xinxing Xu
Wentao Huang
Yan Hu
Nengling Tai
Yaming Ji
Ning Xie
author_facet Xinxing Xu
Wentao Huang
Yan Hu
Nengling Tai
Yaming Ji
Ning Xie
author_sort Xinxing Xu
collection DOAJ
description In the current distribution network, photovoltaic, wind power, energy storage, and other distributed energy are widely connected, and the proportion of generalized DC load is rapidly increasing. With the development of power electronics technology, using multi-port power electronic transformer (PET) to achieve high-efficiency access of large-capacity AC/DC source and load is the current research hotspot, and AC / DC hybrid power supply is inevitable. The introduction of a large number of power electronics and the flexible coordinated control and complementary fault-tolerant advantages of PET bring challenges to the operation and maintenance management of the AC/DC hybrid power system. In this paper, the structure of the AC/DC hybrid power system with the multi-port PET cluster is introduced. Based on the idea of hierarchical and partitioned control, a three-layer and multi-time scale control mode of integrated automation system, PET cluster and PET controller is proposed; Aiming at the problem of reliability evaluation, a sequential Monte Carlo simulation method is proposed to simulate the AC/DC hybrid power system with the multi-port PET cluster. The influence of multi-port PET parallel cluster mode and port capacity limitation on the reliability of the power system is analyzed, and the effectiveness of the model and algorithm is verified. Finally, an example is given to verify that the proposed structure is conducive to improving the utilization level of renewable energy in the distribution network.
first_indexed 2024-12-16T15:01:04Z
format Article
id doaj.art-62d4d7b991a842389fc5e3a8ae8b4fed
institution Directory Open Access Journal
issn 2296-598X
language English
last_indexed 2024-12-16T15:01:04Z
publishDate 2021-09-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Energy Research
spelling doaj.art-62d4d7b991a842389fc5e3a8ae8b4fed2022-12-21T22:27:17ZengFrontiers Media S.A.Frontiers in Energy Research2296-598X2021-09-01910.3389/fenrg.2021.721385721385Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply SystemXinxing Xu0Wentao Huang1Yan Hu2Nengling Tai3Yaming Ji4Ning Xie5Department of Electrical Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaDepartment of Electrical Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaDepartment of Electrical Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaDepartment of Electrical Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, ChinaBeijing Sifang Jibao Automation Co., Ltd., Beijing, ChinaInstitute of Energy Storage, Electric Power Research Institute of Guangdong Power Grid Co., Ltd., Guangzhou, ChinaIn the current distribution network, photovoltaic, wind power, energy storage, and other distributed energy are widely connected, and the proportion of generalized DC load is rapidly increasing. With the development of power electronics technology, using multi-port power electronic transformer (PET) to achieve high-efficiency access of large-capacity AC/DC source and load is the current research hotspot, and AC / DC hybrid power supply is inevitable. The introduction of a large number of power electronics and the flexible coordinated control and complementary fault-tolerant advantages of PET bring challenges to the operation and maintenance management of the AC/DC hybrid power system. In this paper, the structure of the AC/DC hybrid power system with the multi-port PET cluster is introduced. Based on the idea of hierarchical and partitioned control, a three-layer and multi-time scale control mode of integrated automation system, PET cluster and PET controller is proposed; Aiming at the problem of reliability evaluation, a sequential Monte Carlo simulation method is proposed to simulate the AC/DC hybrid power system with the multi-port PET cluster. The influence of multi-port PET parallel cluster mode and port capacity limitation on the reliability of the power system is analyzed, and the effectiveness of the model and algorithm is verified. Finally, an example is given to verify that the proposed structure is conducive to improving the utilization level of renewable energy in the distribution network.https://www.frontiersin.org/articles/10.3389/fenrg.2021.721385/fullAC/DC hybridpower electronic transformerreliabilitycontrolnew energy access
spellingShingle Xinxing Xu
Wentao Huang
Yan Hu
Nengling Tai
Yaming Ji
Ning Xie
Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System
Frontiers in Energy Research
AC/DC hybrid
power electronic transformer
reliability
control
new energy access
title Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System
title_full Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System
title_fullStr Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System
title_full_unstemmed Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System
title_short Power Management of AC/DC Hybrid Distribution Network With Multi-Port PET Considering Reliability of Power Supply System
title_sort power management of ac dc hybrid distribution network with multi port pet considering reliability of power supply system
topic AC/DC hybrid
power electronic transformer
reliability
control
new energy access
url https://www.frontiersin.org/articles/10.3389/fenrg.2021.721385/full
work_keys_str_mv AT xinxingxu powermanagementofacdchybriddistributionnetworkwithmultiportpetconsideringreliabilityofpowersupplysystem
AT wentaohuang powermanagementofacdchybriddistributionnetworkwithmultiportpetconsideringreliabilityofpowersupplysystem
AT yanhu powermanagementofacdchybriddistributionnetworkwithmultiportpetconsideringreliabilityofpowersupplysystem
AT nenglingtai powermanagementofacdchybriddistributionnetworkwithmultiportpetconsideringreliabilityofpowersupplysystem
AT yamingji powermanagementofacdchybriddistributionnetworkwithmultiportpetconsideringreliabilityofpowersupplysystem
AT ningxie powermanagementofacdchybriddistributionnetworkwithmultiportpetconsideringreliabilityofpowersupplysystem