Investigation of Reactant Conversion in the Vanadium Redox Flow Battery Using Spatially Resolved State of Charge Mapping
Segmented cells enable real time visualization of the flow distribution in vanadium redox flow batteries by local current or voltage mapping. The lateral flow of current within thick porous electrodes, however, impairs the local resolution of the detected signals. In this study, the open circuit vol...
Main Authors: | Purna C. Ghimire, Arjun Bhattarai, Rüdiger Schweiss, Günther G. Scherer, Nyunt Wai, Tuti M. Lim, Qingyu Yan |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-01-01
|
Series: | Batteries |
Subjects: | |
Online Access: | http://www.mdpi.com/2313-0105/5/1/2 |
Similar Items
-
Investigation of reactant conversion in the vanadium redox flow battery using spatially resolved state of charge mapping
by: Bhattarai, Arjun, et al.
Published: (2019) -
A comprehensive study of electrode compression effects in all vanadium redox flow batteries including locally resolved measurements
by: Ghimire, Purna C., et al.
Published: (2020) -
Novel Approaches for Solving the Capacity Fade Problem during Operation of a Vanadium Redox Flow Battery
by: Arjun Bhattarai, et al.
Published: (2018-10-01) -
Vanadium redox flow battery with slotted porous electrodes and automatic rebalancing demonstrated on a 1 kW system level
by: Bhattarai, Arjun, et al.
Published: (2021) -
Optimization of thermal oxidation of electrodes for the performance enhancement in all-vanadium redox flow betteries
by: Ghimire, Purna Chandra, et al.
Published: (2020)