Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes
BACKGROUND It is difficult to accurately determine the content of Ag in soil and sediment due to the mass spectrum interference of niobium, zirconium oxide and hydroxide during inductively coupled plasma-mass spectrometry (ICP-MS) analysis. OBJECTIVES To develop methods for the determination of trac...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Science Press, PR China
2022-11-01
|
Series: | Yankuang ceshi |
Subjects: | |
Online Access: | http://www.ykcs.ac.cn/en/article/doi/10.15898/j.cnki.11-2131/td.202112230206 |
_version_ | 1797954167918034944 |
---|---|
author | LIU Yue LIN Dong WANG Jilu LI Jing WANG Xin |
author_facet | LIU Yue LIN Dong WANG Jilu LI Jing WANG Xin |
author_sort | LIU Yue |
collection | DOAJ |
description | BACKGROUND It is difficult to accurately determine the content of Ag in soil and sediment due to the mass spectrum interference of niobium, zirconium oxide and hydroxide during inductively coupled plasma-mass spectrometry (ICP-MS) analysis. OBJECTIVES To develop methods for the determination of trace Ag in soil and sediment samples by four collision/reaction modes. METHODS The changes of mass spectrum signals of 93Nb16O+, 91Zr16OH2+, 92Zr16OH+ and 109Ag+ in helium, oxygen and ammonia were determined using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS). The interference elimination ability and elimination mechanism of different collision/reaction modes were investigated. The samples were digested by HCl-HNO3-HF-HClO4. The content of Ag in soil and stream sediments was determined by helium MS/MS mode, oxygen MS/MS mode, ammonia MS/MS mode and ammonia Mass-Shift mode. RESULTS With the optimal gas flow rate in the tank of the four collision/reaction modes, the interference degree of niobium and zirconium on Ag were decreased more than 20, 1500, 1500 and 2000 times, respectively. The detection limits of the method were 0.005mg/kg, 0.002mg/kg, 0.003mg/kg and 0.003mg/kg, respectively. The accuracy and precision were verified by national reference materials of soil and sediment, while the relative errors of measured values and certified values were -1.4%-84.3%, -7.6%-7.2%, -15.0%-10.0% and -12.5%-8.6%, respectively. The relative standard deviations were 1.5%-6.3%, 1.4%-8.3%, 1.4%-5.9% and 0.7%-8.2%, respectively. CONCLUSIONS Helium MS/MS mode has a low capacity to eliminate mass spectrometry interference, and is suitable for the determination of samples with little interference of niobium and zirconium. Oxygen MS/MS, ammonia MS/MS and ammonia Mass-Shift modes have a strong ability to eliminate mass spectrometry interference, which can be used for the determination of trace Ag in soil and stream sediments; and have the advantages of lower detection limit, wider linear range, and simultaneous determination of multiple elements, when compared with the industry standard DZ/T 0279.11—2016. |
first_indexed | 2024-04-10T23:14:24Z |
format | Article |
id | doaj.art-646702a047ed441e95799a37eb26aeeb |
institution | Directory Open Access Journal |
issn | 0254-5357 |
language | English |
last_indexed | 2024-04-10T23:14:24Z |
publishDate | 2022-11-01 |
publisher | Science Press, PR China |
record_format | Article |
series | Yankuang ceshi |
spelling | doaj.art-646702a047ed441e95799a37eb26aeeb2023-01-13T02:12:11ZengScience Press, PR ChinaYankuang ceshi0254-53572022-11-014161017102810.15898/j.cnki.11-2131/td.202112230206yk202112230206Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction ModesLIU Yue0LIN Dong1WANG Jilu2LI Jing3WANG Xin4Tianjin Eco-Environmental Monitoring Center, Tianjin 300191, ChinaTianjin Eco-Environmental Monitoring Center, Tianjin 300191, ChinaTianjin Eco-Environmental Monitoring Center, Tianjin 300191, ChinaTianjin Eco-Environmental Monitoring Center, Tianjin 300191, ChinaTianjin Eco-Environmental Monitoring Center, Tianjin 300191, ChinaBACKGROUND It is difficult to accurately determine the content of Ag in soil and sediment due to the mass spectrum interference of niobium, zirconium oxide and hydroxide during inductively coupled plasma-mass spectrometry (ICP-MS) analysis. OBJECTIVES To develop methods for the determination of trace Ag in soil and sediment samples by four collision/reaction modes. METHODS The changes of mass spectrum signals of 93Nb16O+, 91Zr16OH2+, 92Zr16OH+ and 109Ag+ in helium, oxygen and ammonia were determined using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS). The interference elimination ability and elimination mechanism of different collision/reaction modes were investigated. The samples were digested by HCl-HNO3-HF-HClO4. The content of Ag in soil and stream sediments was determined by helium MS/MS mode, oxygen MS/MS mode, ammonia MS/MS mode and ammonia Mass-Shift mode. RESULTS With the optimal gas flow rate in the tank of the four collision/reaction modes, the interference degree of niobium and zirconium on Ag were decreased more than 20, 1500, 1500 and 2000 times, respectively. The detection limits of the method were 0.005mg/kg, 0.002mg/kg, 0.003mg/kg and 0.003mg/kg, respectively. The accuracy and precision were verified by national reference materials of soil and sediment, while the relative errors of measured values and certified values were -1.4%-84.3%, -7.6%-7.2%, -15.0%-10.0% and -12.5%-8.6%, respectively. The relative standard deviations were 1.5%-6.3%, 1.4%-8.3%, 1.4%-5.9% and 0.7%-8.2%, respectively. CONCLUSIONS Helium MS/MS mode has a low capacity to eliminate mass spectrometry interference, and is suitable for the determination of samples with little interference of niobium and zirconium. Oxygen MS/MS, ammonia MS/MS and ammonia Mass-Shift modes have a strong ability to eliminate mass spectrometry interference, which can be used for the determination of trace Ag in soil and stream sediments; and have the advantages of lower detection limit, wider linear range, and simultaneous determination of multiple elements, when compared with the industry standard DZ/T 0279.11—2016.http://www.ykcs.ac.cn/en/article/doi/10.15898/j.cnki.11-2131/td.202112230206collision/reaction modessilverinductively coupled plasma-tandem mass spectrometrysoilstream sediments |
spellingShingle | LIU Yue LIN Dong WANG Jilu LI Jing WANG Xin Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes Yankuang ceshi collision/reaction modes silver inductively coupled plasma-tandem mass spectrometry soil stream sediments |
title | Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes |
title_full | Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes |
title_fullStr | Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes |
title_full_unstemmed | Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes |
title_short | Determination of Silver in Soil and Stream Sediments by ICP-MS/MS with Four Collision/Reaction Modes |
title_sort | determination of silver in soil and stream sediments by icp ms ms with four collision reaction modes |
topic | collision/reaction modes silver inductively coupled plasma-tandem mass spectrometry soil stream sediments |
url | http://www.ykcs.ac.cn/en/article/doi/10.15898/j.cnki.11-2131/td.202112230206 |
work_keys_str_mv | AT liuyue determinationofsilverinsoilandstreamsedimentsbyicpmsmswithfourcollisionreactionmodes AT lindong determinationofsilverinsoilandstreamsedimentsbyicpmsmswithfourcollisionreactionmodes AT wangjilu determinationofsilverinsoilandstreamsedimentsbyicpmsmswithfourcollisionreactionmodes AT lijing determinationofsilverinsoilandstreamsedimentsbyicpmsmswithfourcollisionreactionmodes AT wangxin determinationofsilverinsoilandstreamsedimentsbyicpmsmswithfourcollisionreactionmodes |