Optimal Abdominal CT Image Quality in Non-Lean Patients: Customization of CM Injection Protocols and Low-Energy Acquisitions

We compared the image quality of abdominopelvic single-energy CT with 100 kVp (SECT-100 kVp) and dual-energy CT with 65 keV (DECT-65 keV) obtained with customized injection protocols to standard abdominopelvic CT scans (SECT-120 kVp) with fixed volumes of contrast media (CM). We retrospectively incl...

Full description

Bibliographic Details
Main Authors: Francesco Macri, Elina Khasanova, Bonnie T. Niu, Anushri Parakh, Manuel Patino, Avinash Kambadakone, Dushyant V. Sahani
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Diagnostics
Subjects:
Online Access:https://www.mdpi.com/2075-4418/13/13/2279
Description
Summary:We compared the image quality of abdominopelvic single-energy CT with 100 kVp (SECT-100 kVp) and dual-energy CT with 65 keV (DECT-65 keV) obtained with customized injection protocols to standard abdominopelvic CT scans (SECT-120 kVp) with fixed volumes of contrast media (CM). We retrospectively included 91 patients (mean age, 60.7 ± 15.8 years) with SECT-100 kVp and 83 (mean age, 60.3 ± 11.7 years) patients with DECT-65 keV in portovenous phase. Total body weight-based customized injection protocols were generated by a software using the following formula: patient weight (kg) × 0.40/contrast concentration (mgI/mL) × 1000. Patients had a prior abdominopelvic SECT-120 kVp with fixed injection. Iopamidol-370 was administered for all examinations. Quantitative and qualitative image quality comparisons were made between customized and fixed injection protocols. Compared to SECT-120 kVp, customized injection yielded a significant reduction in CM volume (mean difference = 9–12 mL; <i>p</i> ≤ 0.001) and injection rate (mean differences = 0.2–0.4 mL/s; <i>p</i> ≤ 0.001) in all weight categories. Improvements in attenuation, noise, signal-to-noise and contrast-to-noise ratios were observed for both SECT-100 kVp and DECT-65 keV compared to SECT-120 kVp in all weight categories (e.g., pancreas DECT-65 keV, 1.2-attenuation-fold increase vs. SECT-120 kVp; <i>p</i> < 0.001). Qualitative scores were ≥4 in 172 cases (98.8.4%) with customized injections and in all cases with fixed injections (100%). These findings suggest that customized CM injection protocols may substantially reduce iodine dose while yielding higher image quality in SECT-100 kVp and DECT-65 keV abdominopelvic scans compared to SECT-120 kVp using fixed CM volumes.
ISSN:2075-4418