Cardiac Magnetic Resonance Left Ventricle Segmentation and Function Evaluation Using a Trained Deep-Learning Model

Cardiac MRI is the gold standard for evaluating left ventricular myocardial mass (LVMM), end-systolic volume (LVESV), end-diastolic volume (LVEDV), stroke volume (LVSV), and ejection fraction (LVEF). Deep convolutional neural networks (CNNs) can provide automatic segmentation of LV myocardium (LVF)...

Full description

Bibliographic Details
Main Authors: Fumin Guo, Matthew Ng, Idan Roifman, Graham Wright
Format: Article
Language:English
Published: MDPI AG 2022-03-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/12/5/2627
Description
Summary:Cardiac MRI is the gold standard for evaluating left ventricular myocardial mass (LVMM), end-systolic volume (LVESV), end-diastolic volume (LVEDV), stroke volume (LVSV), and ejection fraction (LVEF). Deep convolutional neural networks (CNNs) can provide automatic segmentation of LV myocardium (LVF) and blood cavity (LVC) and quantification of LV function; however, the performance is typically degraded when applied to new datasets. A 2D U-net with Monte-Carlo dropout was trained on 45 cine MR images and the model was used to segment 10 subjects from the ACDC dataset. The initial segmentations were post-processed using a continuous kernel-cut method. The refined segmentations were employed to update the trained model. This procedure was iterated several times and the final updated U-net model was used to segment the remaining 90 ACDC subjects. Algorithm and manual segmentations were compared using Dice coefficient (DSC) and average surface distance in a symmetric manner (ASSD). The relationships between algorithm and manual LV indices were evaluated using Pearson correlation coefficient (r), Bland-Altman analyses, and paired <i>t</i>-tests. Direct application of the pre-trained model yielded DSC of 0.74 ± 0.12 for LVM and 0.87 ± 0.12 for LVC. After fine-tuning, DSC was 0.81 ± 0.09 for LVM and 0.90 ± 0.09 for LVC. Algorithm LV function measurements were strongly correlated with manual analyses (r = 0.86–0.99, <i>p</i> < 0.0001) with minimal biases of −8.8 g for LVMM, −0.9 mL for LVEDV, −0.2 mL for LVESV, −0.7 mL for LVSV, and −0.6% for LVEF. The procedure required ∼12 min for fine-tuning and approximately 1 s to contour a new image on a Linux (Ubuntu 14.02) desktop (Inter(R) CPU i7-7770, 4.2 GHz, 16 GB RAM) with a GPU (GeForce, GTX TITAN X, 12 GB Memory). This approach provides a way to incorporate a trained CNN to segment and quantify previously unseen cardiac MR datasets without needing manual annotation of the unseen datasets.
ISSN:2076-3417