DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control

In order to improve the dynamic response speed and the steady-state performance of the DC side bus voltage of the wind power grid-connected inverter, a mathematical model of a typical three-phase voltage type PWM (Pulse Width Modulation, PWM) grid-connected inverter was established, and its traditio...

Full description

Bibliographic Details
Main Authors: Youjie Ma, Faqing Zhao, Xuesong Zhou, Mao Liu, Bao Yang
Format: Article
Language:English
Published: MDPI AG 2019-11-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/12/22/4274
_version_ 1818475053670465536
author Youjie Ma
Faqing Zhao
Xuesong Zhou
Mao Liu
Bao Yang
author_facet Youjie Ma
Faqing Zhao
Xuesong Zhou
Mao Liu
Bao Yang
author_sort Youjie Ma
collection DOAJ
description In order to improve the dynamic response speed and the steady-state performance of the DC side bus voltage of the wind power grid-connected inverter, a mathematical model of a typical three-phase voltage type PWM (Pulse Width Modulation, PWM) grid-connected inverter was established, and its traditional voltage-current double closed loop with proportional-integral control method was analyzed. Then a second-order linear active disturbance rejection controller that does not depend on system model information was designed to replace the traditional voltage outer loop proportional-integral controller, thus a new double closed-loop control structure was formed to control it. The frequency domain theory was used to analyze the convergence of the third-order linear extended state observer and the influence of the total disturbance on the performance of the third-order linear extended state observer. The parameter tuning scheme of the designed controller was given. Finally, the 1.5 MW direct-driven permanent magnet wind power generation system was built in the Matlab/Simulink software and the control effects of the two control modes under different working conditions are compared. The simulation results show that the control scheme designed in this paper is superior to the traditional proportional-integral controller which has good anti-interference characteristics and robustness. Especially it has a good stability effect on DC side bus voltage fluctuations.
first_indexed 2024-04-14T04:44:29Z
format Article
id doaj.art-653c8ce2e6604059a6e2a31527bb3ef1
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-14T04:44:29Z
publishDate 2019-11-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-653c8ce2e6604059a6e2a31527bb3ef12022-12-22T02:11:29ZengMDPI AGEnergies1996-10732019-11-011222427410.3390/en12224274en12224274DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection ControlYoujie Ma0Faqing Zhao1Xuesong Zhou2Mao Liu3Bao Yang4Tianjin Key Laboratory for Control Theory and Application in Complicated Systems, Tianjin University of Technology, Tianjin 300384, ChinaTianjin Key Laboratory for Control Theory and Application in Complicated Systems, Tianjin University of Technology, Tianjin 300384, ChinaTianjin Key Laboratory for Control Theory and Application in Complicated Systems, Tianjin University of Technology, Tianjin 300384, ChinaTianjin Key Laboratory for Control Theory and Application in Complicated Systems, Tianjin University of Technology, Tianjin 300384, ChinaTianjin Key Laboratory for Control Theory and Application in Complicated Systems, Tianjin University of Technology, Tianjin 300384, ChinaIn order to improve the dynamic response speed and the steady-state performance of the DC side bus voltage of the wind power grid-connected inverter, a mathematical model of a typical three-phase voltage type PWM (Pulse Width Modulation, PWM) grid-connected inverter was established, and its traditional voltage-current double closed loop with proportional-integral control method was analyzed. Then a second-order linear active disturbance rejection controller that does not depend on system model information was designed to replace the traditional voltage outer loop proportional-integral controller, thus a new double closed-loop control structure was formed to control it. The frequency domain theory was used to analyze the convergence of the third-order linear extended state observer and the influence of the total disturbance on the performance of the third-order linear extended state observer. The parameter tuning scheme of the designed controller was given. Finally, the 1.5 MW direct-driven permanent magnet wind power generation system was built in the Matlab/Simulink software and the control effects of the two control modes under different working conditions are compared. The simulation results show that the control scheme designed in this paper is superior to the traditional proportional-integral controller which has good anti-interference characteristics and robustness. Especially it has a good stability effect on DC side bus voltage fluctuations.https://www.mdpi.com/1996-1073/12/22/4274wind power grid-connected inverterdual-loop controlsecond-order linear active disturbance rejectionlinear extended state observerfrequency domain analysis
spellingShingle Youjie Ma
Faqing Zhao
Xuesong Zhou
Mao Liu
Bao Yang
DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control
Energies
wind power grid-connected inverter
dual-loop control
second-order linear active disturbance rejection
linear extended state observer
frequency domain analysis
title DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control
title_full DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control
title_fullStr DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control
title_full_unstemmed DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control
title_short DC Side Bus Voltage Control of Wind Power Grid-Connected Inverter Based on Second-Order Linear Active Disturbance Rejection Control
title_sort dc side bus voltage control of wind power grid connected inverter based on second order linear active disturbance rejection control
topic wind power grid-connected inverter
dual-loop control
second-order linear active disturbance rejection
linear extended state observer
frequency domain analysis
url https://www.mdpi.com/1996-1073/12/22/4274
work_keys_str_mv AT youjiema dcsidebusvoltagecontrolofwindpowergridconnectedinverterbasedonsecondorderlinearactivedisturbancerejectioncontrol
AT faqingzhao dcsidebusvoltagecontrolofwindpowergridconnectedinverterbasedonsecondorderlinearactivedisturbancerejectioncontrol
AT xuesongzhou dcsidebusvoltagecontrolofwindpowergridconnectedinverterbasedonsecondorderlinearactivedisturbancerejectioncontrol
AT maoliu dcsidebusvoltagecontrolofwindpowergridconnectedinverterbasedonsecondorderlinearactivedisturbancerejectioncontrol
AT baoyang dcsidebusvoltagecontrolofwindpowergridconnectedinverterbasedonsecondorderlinearactivedisturbancerejectioncontrol