Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume

Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease o...

Full description

Bibliographic Details
Main Authors: T Naderi, Y Nikian, F Amin Zadeh
Format: Article
Language:English
Published: Babol University of Medical Sciences 2002-01-01
Series:Majallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul
Subjects:
Online Access:http://jbums.org/article-1-2836-en.html
_version_ 1818932018061246464
author T Naderi
Y Nikian
F Amin Zadeh
author_facet T Naderi
Y Nikian
F Amin Zadeh
author_sort T Naderi
collection DOAJ
description Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease of amniotic fluid volume according to sonography report. Methods: This cross-sectional study was done on 120 women referred to Bahonar hospital in Kerman. It was performed on all pregnant women with gestational age of 38-42 who complained of decrease of fetal movement (84.2%) and a decrease of amniotic fluid volume (61%) was reported in their sonography. Findings: The result of NST in 64.1% of patients was non-reactive and in 35.9% was reactive. 41.7% of cases were with fetal distress during labor or delivery, of which 94.1% had non-reactive NST. The sensitivity and specificity of NST in cases with decrease of amniotic fluid were 89% and 74.5%, respectively and in cases with complaint of decreased fetal movement were 63.4% and 32%, 7 respectively. Conclusion: Exact heart rate monitor in cases with complaint of decreased fetal movement or amniotic fluid volume and also with non-reactive NST in necessary.
first_indexed 2024-12-20T04:25:48Z
format Article
id doaj.art-657c064be45f46afa87b472639e89320
institution Directory Open Access Journal
issn 1561-4107
2251-7170
language English
last_indexed 2024-12-20T04:25:48Z
publishDate 2002-01-01
publisher Babol University of Medical Sciences
record_format Article
series Majallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul
spelling doaj.art-657c064be45f46afa87b472639e893202022-12-21T19:53:31ZengBabol University of Medical SciencesMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul1561-41072251-71702002-01-0141710Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volumeT Naderi0Y Nikian1F Amin Zadeh2 Background and Objective: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased fetal movement or decrease of amniotic fluid volume according to sonography report. Methods: This cross-sectional study was done on 120 women referred to Bahonar hospital in Kerman. It was performed on all pregnant women with gestational age of 38-42 who complained of decrease of fetal movement (84.2%) and a decrease of amniotic fluid volume (61%) was reported in their sonography. Findings: The result of NST in 64.1% of patients was non-reactive and in 35.9% was reactive. 41.7% of cases were with fetal distress during labor or delivery, of which 94.1% had non-reactive NST. The sensitivity and specificity of NST in cases with decrease of amniotic fluid were 89% and 74.5%, respectively and in cases with complaint of decreased fetal movement were 63.4% and 32%, 7 respectively. Conclusion: Exact heart rate monitor in cases with complaint of decreased fetal movement or amniotic fluid volume and also with non-reactive NST in necessary.http://jbums.org/article-1-2836-en.htmlnstfetal movementoligohydramnios
spellingShingle T Naderi
Y Nikian
F Amin Zadeh
Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
Majallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul
nst
fetal movement
oligohydramnios
title Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_full Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_fullStr Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_full_unstemmed Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_short Sensitivity and specificity of NST in cases with decrease of fetal movement and amniotic fluid volume
title_sort sensitivity and specificity of nst in cases with decrease of fetal movement and amniotic fluid volume
topic nst
fetal movement
oligohydramnios
url http://jbums.org/article-1-2836-en.html
work_keys_str_mv AT tnaderi sensitivityandspecificityofnstincaseswithdecreaseoffetalmovementandamnioticfluidvolume
AT ynikian sensitivityandspecificityofnstincaseswithdecreaseoffetalmovementandamnioticfluidvolume
AT faminzadeh sensitivityandspecificityofnstincaseswithdecreaseoffetalmovementandamnioticfluidvolume