Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers

This paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s desi...

Full description

Bibliographic Details
Main Authors: Sarven Akcelyan, Dimitrios G. Lignos
Format: Article
Language:English
Published: MDPI AG 2023-01-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/13/1/139
_version_ 1827627757377421312
author Sarven Akcelyan
Dimitrios G. Lignos
author_facet Sarven Akcelyan
Dimitrios G. Lignos
author_sort Sarven Akcelyan
collection DOAJ
description This paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous seismic performance assessment based on ASCE 41 recommendations reveals a high collapse risk for the existing building. The local engineering demand parameters are comprehensively assessed to quantify the impact of seismic retrofit on steel columns and column splices, which are particularly vulnerable due to the time of construction. Multiple retrofit schemes are explored with numerous damping levels and vertical damping distribution methods. The dampers are designed via a recently developed multi-degree-of-freedom performance curves method. A new balanced vertical damping method is proposed to account for the effects of frame inelasticity. This strongly depends on the supplemental damping level, and it determines the effectiveness of the employed vertical damping distribution method. The results indicate that the proposed retrofit strategies can minimize the collapse risk of the tall building. It is shown that the balanced vertical damping distribution method provides the most uniform drift distribution along the building height. Despite the reduction in story drift ratios, the axial force demand in exterior columns remains relatively high in the bottom stories regardless of the seismic retrofit solution. On the other hand, bilinear oil dampers produce relative constant forces despite exhibiting higher velocity demands than expected.
first_indexed 2024-03-09T13:20:25Z
format Article
id doaj.art-658a3ca456e64cea978cb7b51cf8c190
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T13:20:25Z
publishDate 2023-01-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-658a3ca456e64cea978cb7b51cf8c1902023-11-30T21:30:26ZengMDPI AGBuildings2075-53092023-01-0113113910.3390/buildings13010139Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil DampersSarven Akcelyan0Dimitrios G. Lignos1Department of Civil Engineering, Kadir Has University, Cibali, Istanbul 34083, TurkeyCivil Engineering Institute, École Polytechnique Fédérale de Lausanne (EPFL), EPFL ENAC IIC RESSLab, GC B3 485, Station 18, CH-1015 Lausanne, SwitzerlandThis paper presents quantitative information on the effectiveness of seismic retrofit solutions using bilinear oil dampers for seismically deficient existing tall steel buildings. For this purpose, a benchmark 40-story steel space moment-resisting frame building is studied that represents 1970s design practice in North America. Rigorous seismic performance assessment based on ASCE 41 recommendations reveals a high collapse risk for the existing building. The local engineering demand parameters are comprehensively assessed to quantify the impact of seismic retrofit on steel columns and column splices, which are particularly vulnerable due to the time of construction. Multiple retrofit schemes are explored with numerous damping levels and vertical damping distribution methods. The dampers are designed via a recently developed multi-degree-of-freedom performance curves method. A new balanced vertical damping method is proposed to account for the effects of frame inelasticity. This strongly depends on the supplemental damping level, and it determines the effectiveness of the employed vertical damping distribution method. The results indicate that the proposed retrofit strategies can minimize the collapse risk of the tall building. It is shown that the balanced vertical damping distribution method provides the most uniform drift distribution along the building height. Despite the reduction in story drift ratios, the axial force demand in exterior columns remains relatively high in the bottom stories regardless of the seismic retrofit solution. On the other hand, bilinear oil dampers produce relative constant forces despite exhibiting higher velocity demands than expected.https://www.mdpi.com/2075-5309/13/1/139supplemental dampingbilinear oil dampersseismic retrofitcollapse riskperformance-based designtall buildings
spellingShingle Sarven Akcelyan
Dimitrios G. Lignos
Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
Buildings
supplemental damping
bilinear oil dampers
seismic retrofit
collapse risk
performance-based design
tall buildings
title Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
title_full Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
title_fullStr Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
title_full_unstemmed Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
title_short Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
title_sort seismic assessment and retrofit of pre northridge high rise steel moment resisting frame buildings with bilinear oil dampers
topic supplemental damping
bilinear oil dampers
seismic retrofit
collapse risk
performance-based design
tall buildings
url https://www.mdpi.com/2075-5309/13/1/139
work_keys_str_mv AT sarvenakcelyan seismicassessmentandretrofitofprenorthridgehighrisesteelmomentresistingframebuildingswithbilinearoildampers
AT dimitriosglignos seismicassessmentandretrofitofprenorthridgehighrisesteelmomentresistingframebuildingswithbilinearoildampers