Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants

No evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece cera...

Full description

Bibliographic Details
Main Authors: Frank A. Spitznagel, Johanna S. Hoppe, Estevam A. Bonfante, Tiago M. B. Campos, Robert Langner, Petra C. Gierthmuehlen
Format: Article
Language:English
Published: MDPI AG 2022-11-01
Series:Materials
Subjects:
Online Access:https://www.mdpi.com/1996-1944/15/23/8465
_version_ 1797462866944589824
author Frank A. Spitznagel
Johanna S. Hoppe
Estevam A. Bonfante
Tiago M. B. Campos
Robert Langner
Petra C. Gierthmuehlen
author_facet Frank A. Spitznagel
Johanna S. Hoppe
Estevam A. Bonfante
Tiago M. B. Campos
Robert Langner
Petra C. Gierthmuehlen
author_sort Frank A. Spitznagel
collection DOAJ
description No evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece ceramic implants. Eighty 3-unit FDPs supported by 160 zirconia-implants (ceramic.implant; vitaclinical) were divided into 4 groups (<i>n</i> = 20 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Group FL: 3Y-TZP zirconia (Vita-YZ-HT) with facial-veneer (Vita-VM9); Group RL (Rapid-layer): PICN “table-top” (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the test samples (<i>n</i> = 10/group) were fatigued in a mouth-motion chewing-simulator (F = 98 N, 1.2 million-cycles) with simultaneous thermocycling (5–55 °C). All specimens (fatigued and non-fatigued) were afterwards exposed to single-load-to-failure-testing (Z010, Zwick). Statistical analysis was performed using ANOVA, Tukey’s post-hoc tests and two-sample <i>t</i>-tests (<i>p</i> < 0.05, Bonferroni-corrected where appropriate). All specimens withstood fatigue application. While the effect of fatigue was not significant in any group (<i>p</i> = 0.714), the choice of material had a significant effect (<i>p</i> < 0.001). Material FL recorded the highest failure loads, followed by Z-ST, Z-HT and RL, both with and without fatigue application. Taken together, all tested FDP material combinations survived chewing forces that exceeded physiological levels. Bi-Layer FL and monolithic Z-ST showed the highest resilience and might serve as reliable prosthetic reconstruction concepts for 3-unit FDPs on ceramic implants.
first_indexed 2024-03-09T17:42:36Z
format Article
id doaj.art-65b8e79e1b854d34b18222029137e22c
institution Directory Open Access Journal
issn 1996-1944
language English
last_indexed 2024-03-09T17:42:36Z
publishDate 2022-11-01
publisher MDPI AG
record_format Article
series Materials
spelling doaj.art-65b8e79e1b854d34b18222029137e22c2023-11-24T11:28:42ZengMDPI AGMaterials1996-19442022-11-011523846510.3390/ma15238465Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia ImplantsFrank A. Spitznagel0Johanna S. Hoppe1Estevam A. Bonfante2Tiago M. B. Campos3Robert Langner4Petra C. Gierthmuehlen5Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University, Moorenstraße 5, 40225 Düsseldorf, GermanyDepartment of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University, Moorenstraße 5, 40225 Düsseldorf, GermanyDepartment of Prosthodontics and Periodontology; Bauru School of Dentistry, University of Sao Paulo, Bauru 17012-230, SP, BrazilDepartment of Prosthodontics and Periodontology; Bauru School of Dentistry, University of Sao Paulo, Bauru 17012-230, SP, BrazilInstitute of Systems Neuroscience, Medical Faculty, Heinrich-Heine-University, 40225 Düsseldorf, GermanyDepartment of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine University, Moorenstraße 5, 40225 Düsseldorf, GermanyNo evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece ceramic implants. Eighty 3-unit FDPs supported by 160 zirconia-implants (ceramic.implant; vitaclinical) were divided into 4 groups (<i>n</i> = 20 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Group FL: 3Y-TZP zirconia (Vita-YZ-HT) with facial-veneer (Vita-VM9); Group RL (Rapid-layer): PICN “table-top” (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the test samples (<i>n</i> = 10/group) were fatigued in a mouth-motion chewing-simulator (F = 98 N, 1.2 million-cycles) with simultaneous thermocycling (5–55 °C). All specimens (fatigued and non-fatigued) were afterwards exposed to single-load-to-failure-testing (Z010, Zwick). Statistical analysis was performed using ANOVA, Tukey’s post-hoc tests and two-sample <i>t</i>-tests (<i>p</i> < 0.05, Bonferroni-corrected where appropriate). All specimens withstood fatigue application. While the effect of fatigue was not significant in any group (<i>p</i> = 0.714), the choice of material had a significant effect (<i>p</i> < 0.001). Material FL recorded the highest failure loads, followed by Z-ST, Z-HT and RL, both with and without fatigue application. Taken together, all tested FDP material combinations survived chewing forces that exceeded physiological levels. Bi-Layer FL and monolithic Z-ST showed the highest resilience and might serve as reliable prosthetic reconstruction concepts for 3-unit FDPs on ceramic implants.https://www.mdpi.com/1996-1944/15/23/8465dental implantzirconiumceramicsfatigueagingdental restoration failure
spellingShingle Frank A. Spitznagel
Johanna S. Hoppe
Estevam A. Bonfante
Tiago M. B. Campos
Robert Langner
Petra C. Gierthmuehlen
Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
Materials
dental implant
zirconium
ceramics
fatigue
aging
dental restoration failure
title Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
title_full Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
title_fullStr Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
title_full_unstemmed Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
title_short Failure Load and Fatigue Behavior of Monolithic and Bi-Layer Zirconia Fixed Dental Prostheses Bonded to One-Piece Zirconia Implants
title_sort failure load and fatigue behavior of monolithic and bi layer zirconia fixed dental prostheses bonded to one piece zirconia implants
topic dental implant
zirconium
ceramics
fatigue
aging
dental restoration failure
url https://www.mdpi.com/1996-1944/15/23/8465
work_keys_str_mv AT frankaspitznagel failureloadandfatiguebehaviorofmonolithicandbilayerzirconiafixeddentalprosthesesbondedtoonepiecezirconiaimplants
AT johannashoppe failureloadandfatiguebehaviorofmonolithicandbilayerzirconiafixeddentalprosthesesbondedtoonepiecezirconiaimplants
AT estevamabonfante failureloadandfatiguebehaviorofmonolithicandbilayerzirconiafixeddentalprosthesesbondedtoonepiecezirconiaimplants
AT tiagombcampos failureloadandfatiguebehaviorofmonolithicandbilayerzirconiafixeddentalprosthesesbondedtoonepiecezirconiaimplants
AT robertlangner failureloadandfatiguebehaviorofmonolithicandbilayerzirconiafixeddentalprosthesesbondedtoonepiecezirconiaimplants
AT petracgierthmuehlen failureloadandfatiguebehaviorofmonolithicandbilayerzirconiafixeddentalprosthesesbondedtoonepiecezirconiaimplants