Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity

Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of...

Full description

Bibliographic Details
Main Authors: Michael O. Harris-Love, Bryant A. Seamon, Carla Teixeira, Catheeja Ismail
Format: Article
Language:English
Published: PeerJ Inc. 2016-02-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/1721.pdf
_version_ 1797419584172589056
author Michael O. Harris-Love
Bryant A. Seamon
Carla Teixeira
Catheeja Ismail
author_facet Michael O. Harris-Love
Bryant A. Seamon
Carla Teixeira
Catheeja Ismail
author_sort Michael O. Harris-Love
collection DOAJ
description Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults.
first_indexed 2024-03-09T06:50:07Z
format Article
id doaj.art-65fe1928fc51487fbc7a232054e29c50
institution Directory Open Access Journal
issn 2167-8359
language English
last_indexed 2024-03-09T06:50:07Z
publishDate 2016-02-01
publisher PeerJ Inc.
record_format Article
series PeerJ
spelling doaj.art-65fe1928fc51487fbc7a232054e29c502023-12-03T10:29:02ZengPeerJ Inc.PeerJ2167-83592016-02-014e172110.7717/peerj.1721Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicityMichael O. Harris-Love0Bryant A. Seamon1Carla Teixeira2Catheeja Ismail3Muscle Morphology, Mechanics and Performance Laboratory, Clinical Research Center, Washington DC Veterans Affairs Medical Center, Washington, DC, United StatesMuscle Morphology, Mechanics and Performance Laboratory, Clinical Research Center, Washington DC Veterans Affairs Medical Center, Washington, DC, United StatesMuscle Morphology, Mechanics and Performance Laboratory, Clinical Research Center, Washington DC Veterans Affairs Medical Center, Washington, DC, United StatesMuscle Morphology, Mechanics and Performance Laboratory, Clinical Research Center, Washington DC Veterans Affairs Medical Center, Washington, DC, United StatesBackground. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults.https://peerj.com/articles/1721.pdfUltrasoundGrayscale histogram analysisMuscle echogenicityImageJPhotoshopGeriatrics
spellingShingle Michael O. Harris-Love
Bryant A. Seamon
Carla Teixeira
Catheeja Ismail
Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
PeerJ
Ultrasound
Grayscale histogram analysis
Muscle echogenicity
ImageJ
Photoshop
Geriatrics
title Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_full Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_fullStr Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_full_unstemmed Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_short Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity
title_sort ultrasound estimates of muscle quality in older adults reliability and comparison of photoshop and imagej for the grayscale analysis of muscle echogenicity
topic Ultrasound
Grayscale histogram analysis
Muscle echogenicity
ImageJ
Photoshop
Geriatrics
url https://peerj.com/articles/1721.pdf
work_keys_str_mv AT michaeloharrislove ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity
AT bryantaseamon ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity
AT carlateixeira ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity
AT catheejaismail ultrasoundestimatesofmusclequalityinolderadultsreliabilityandcomparisonofphotoshopandimagejforthegrayscaleanalysisofmuscleechogenicity