Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado

It were established correlations among methods of sperm plasmatic membrane evaluation, by analyzing cryopreserved semen of five Nelore bulls, within three replicates / bull. After thawing at 37°C/30 seconds, there were assessed motility (%), concentration (x106), morphology (%) and membrane integrit...

Full description

Bibliographic Details
Main Authors: Thaíse Silva Passos, Paula Rosa Carrijo, Patrícia Arakaki Leite, Carmem Estefânia Serra Neto Zúccari, Charles Kiefer
Format: Article
Language:English
Published: Universidade Federal da Bahia 2009-09-01
Series:Revista Brasileira de Saúde e Produção Animal
Online Access:http://revistas.ufba.br/index.php/rbspa/article/view/1502
_version_ 1797711170805694464
author Thaíse Silva Passos
Paula Rosa Carrijo
Patrícia Arakaki Leite
Carmem Estefânia Serra Neto Zúccari
Charles Kiefer
author_facet Thaíse Silva Passos
Paula Rosa Carrijo
Patrícia Arakaki Leite
Carmem Estefânia Serra Neto Zúccari
Charles Kiefer
author_sort Thaíse Silva Passos
collection DOAJ
description It were established correlations among methods of sperm plasmatic membrane evaluation, by analyzing cryopreserved semen of five Nelore bulls, within three replicates / bull. After thawing at 37°C/30 seconds, there were assessed motility (%), concentration (x106), morphology (%) and membrane integrity. To evaluate membrane integrity, hypoosmotic test (HOS), fluorescence (FLU) and eosin/nigrosin (EN) were used. Data were submitted to Pearson´s correlation analysis. According to the results, there was correlation between fluorescence vs eosin/nigrosin (r = 0.74; p&lt;0.0013), fluorescence vs hypoosmotic test (r = 0.71; p&lt;0.0029) and eosin/nigrosin vs hypoosmotic test (r = 0.59; p&lt;0.0202). There was also correlation among motility and fluorescence (r = 0.70; p&lt;0.0036), hypoosmotic test (r = 0.78; p&lt;0.0006) and eosin/nigrosin (r = 0.52; p&lt;0.0436). We conclude that the three methods were efficacious in evaluating plasmatic membrane integrity of bovine frozen-thawed spermatozoa, and each laboratory could make its choice according to disposable equipments.<br>O objetivo, com este trabalho, foi verificar a correlação entre métodos de avaliação da integridade da membrana plasmática (IMP), no sêmen congelado comercial de cinco touros da raça Nelore, com três repetições por animal. Após o descongelamento a 37C/30 segundos, foram analisadas as variáveis motilidade (%), concentração (x106/ml), morfologia (%) e IMP. Para a avaliação da IMP, foram usados o teste hiposmótico (HOS), fluorescência (FLU) e eosina/nigrosina (EN), e contadas 100 células/lâmina. Os dados foram submetidos à análise de correlação de Pearson. Houve correlação entre as técnicas de fluorescência vs eosina/nigrosina (r = 0,74; p&lt;0,0013), fluorescência vs teste hiposmótico (r = 0,71; p&lt;0,0029) e correlação de média intensidade entre eosina/nigrosina vs teste hiposmótico (r = 0,59; p&lt;0,0202). Houve correlação entre motilidade e fluorescência (r = 0,70; p&lt;0,0036); teste hiposmótico (r = 0,78; p&lt;0,0006) e eosina/nigrosina (r = 0,52; p&lt;0,0436). Concluiu-se que os métodos hiposmótico, da fluorescência e eosina/nigrosina foram eficazes para a avaliação da integridade da membrana plasmática do espermatozóide congelado de touro, e a escolha do mais indicado dependerá da disponibilidade de equipamentos de cada laboratório.
first_indexed 2024-03-12T07:03:09Z
format Article
id doaj.art-6635236c815845a8a62e94c8702fb340
institution Directory Open Access Journal
issn 1519-9940
language English
last_indexed 2024-03-12T07:03:09Z
publishDate 2009-09-01
publisher Universidade Federal da Bahia
record_format Article
series Revista Brasileira de Saúde e Produção Animal
spelling doaj.art-6635236c815845a8a62e94c8702fb3402023-09-02T23:36:54ZengUniversidade Federal da BahiaRevista Brasileira de Saúde e Produção Animal1519-99402009-09-01103Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservadoThaíse Silva PassosPaula Rosa CarrijoPatrícia Arakaki LeiteCarmem Estefânia Serra Neto ZúccariCharles KieferIt were established correlations among methods of sperm plasmatic membrane evaluation, by analyzing cryopreserved semen of five Nelore bulls, within three replicates / bull. After thawing at 37°C/30 seconds, there were assessed motility (%), concentration (x106), morphology (%) and membrane integrity. To evaluate membrane integrity, hypoosmotic test (HOS), fluorescence (FLU) and eosin/nigrosin (EN) were used. Data were submitted to Pearson´s correlation analysis. According to the results, there was correlation between fluorescence vs eosin/nigrosin (r = 0.74; p&lt;0.0013), fluorescence vs hypoosmotic test (r = 0.71; p&lt;0.0029) and eosin/nigrosin vs hypoosmotic test (r = 0.59; p&lt;0.0202). There was also correlation among motility and fluorescence (r = 0.70; p&lt;0.0036), hypoosmotic test (r = 0.78; p&lt;0.0006) and eosin/nigrosin (r = 0.52; p&lt;0.0436). We conclude that the three methods were efficacious in evaluating plasmatic membrane integrity of bovine frozen-thawed spermatozoa, and each laboratory could make its choice according to disposable equipments.<br>O objetivo, com este trabalho, foi verificar a correlação entre métodos de avaliação da integridade da membrana plasmática (IMP), no sêmen congelado comercial de cinco touros da raça Nelore, com três repetições por animal. Após o descongelamento a 37C/30 segundos, foram analisadas as variáveis motilidade (%), concentração (x106/ml), morfologia (%) e IMP. Para a avaliação da IMP, foram usados o teste hiposmótico (HOS), fluorescência (FLU) e eosina/nigrosina (EN), e contadas 100 células/lâmina. Os dados foram submetidos à análise de correlação de Pearson. Houve correlação entre as técnicas de fluorescência vs eosina/nigrosina (r = 0,74; p&lt;0,0013), fluorescência vs teste hiposmótico (r = 0,71; p&lt;0,0029) e correlação de média intensidade entre eosina/nigrosina vs teste hiposmótico (r = 0,59; p&lt;0,0202). Houve correlação entre motilidade e fluorescência (r = 0,70; p&lt;0,0036); teste hiposmótico (r = 0,78; p&lt;0,0006) e eosina/nigrosina (r = 0,52; p&lt;0,0436). Concluiu-se que os métodos hiposmótico, da fluorescência e eosina/nigrosina foram eficazes para a avaliação da integridade da membrana plasmática do espermatozóide congelado de touro, e a escolha do mais indicado dependerá da disponibilidade de equipamentos de cada laboratório.http://revistas.ufba.br/index.php/rbspa/article/view/1502
spellingShingle Thaíse Silva Passos
Paula Rosa Carrijo
Patrícia Arakaki Leite
Carmem Estefânia Serra Neto Zúccari
Charles Kiefer
Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado
Revista Brasileira de Saúde e Produção Animal
title Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado
title_full Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado
title_fullStr Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado
title_full_unstemmed Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado
title_short Correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm Correlação entre métodos de avaliação da integridade da membrana plasmática do espermatozóide bovino criopreservado
title_sort correlation among methods to evaluate sperm membrane integrity of bovine cryopreserved sperm correlacao entre metodos de avaliacao da integridade da membrana plasmatica do espermatozoide bovino criopreservado
url http://revistas.ufba.br/index.php/rbspa/article/view/1502
work_keys_str_mv AT thaisesilvapassos correlationamongmethodstoevaluatespermmembraneintegrityofbovinecryopreservedspermcorrelacaoentremetodosdeavaliacaodaintegridadedamembranaplasmaticadoespermatozoidebovinocriopreservado
AT paularosacarrijo correlationamongmethodstoevaluatespermmembraneintegrityofbovinecryopreservedspermcorrelacaoentremetodosdeavaliacaodaintegridadedamembranaplasmaticadoespermatozoidebovinocriopreservado
AT patriciaarakakileite correlationamongmethodstoevaluatespermmembraneintegrityofbovinecryopreservedspermcorrelacaoentremetodosdeavaliacaodaintegridadedamembranaplasmaticadoespermatozoidebovinocriopreservado
AT carmemestefaniaserranetozuccari correlationamongmethodstoevaluatespermmembraneintegrityofbovinecryopreservedspermcorrelacaoentremetodosdeavaliacaodaintegridadedamembranaplasmaticadoespermatozoidebovinocriopreservado
AT charleskiefer correlationamongmethodstoevaluatespermmembraneintegrityofbovinecryopreservedspermcorrelacaoentremetodosdeavaliacaodaintegridadedamembranaplasmaticadoespermatozoidebovinocriopreservado