Development of neutron spectrum analysis method to assess the content of fissile isotopes in SFA
The paper presents the integrated neutron spectrum analysis as a potential method for estimating the contents of fissile isotopes in SFAs. Two method implementation variants are described: (1) measurement of SFA average transmission and (2) measurement of sample average transmission in the spectrum...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
National Research Nuclear University (MEPhI)
2015-11-01
|
Series: | Nuclear Energy and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2452303816000169 |
Summary: | The paper presents the integrated neutron spectrum analysis as a potential method for estimating the contents of fissile isotopes in SFAs. Two method implementation variants are described: (1) measurement of SFA average transmission and (2) measurement of sample average transmission in the spectrum that has passed a SFA. The authors describe the dependences of SFA average transmission on its content of the required isotope obtained by means of two types of detectors: helium counter tube and fission chamber. Also, the authors propose a method to estimate SFA burn-up by means of the integrated NSA. In addition, SFA residence time influence on transmission is estimated. |
---|---|