Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods
Two accurate, precise and sensitive RP-HPLC and HPTLC-Densitometric methods have been developed for the determination of Carbazochrome and Troxerutin in their binary mixture without previous separation. Method (A) is RP-HPLC which depended on isocratic elution using C18 column and mobile phase consi...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Pharmacy, Cairo University
2016-06-01
|
Series: | Bulletin of Faculty of Pharmacy Cairo University |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S111009311600003X |
_version_ | 1797970242381545472 |
---|---|
author | Maha Mohamed Abdelrahman Eglal Abdelhameed Abdelaleem Nouruddin Wageih Ali Raghda Abdelmoneim Emam |
author_facet | Maha Mohamed Abdelrahman Eglal Abdelhameed Abdelaleem Nouruddin Wageih Ali Raghda Abdelmoneim Emam |
author_sort | Maha Mohamed Abdelrahman |
collection | DOAJ |
description | Two accurate, precise and sensitive RP-HPLC and HPTLC-Densitometric methods have been developed for the determination of Carbazochrome and Troxerutin in their binary mixture without previous separation. Method (A) is RP-HPLC which depended on isocratic elution using C18 column and mobile phase consisting of water containing (0.2% triethylamine (TEA), 1% tetrahydrofuran (THF)):methanol (65:35, by volume) at a flow rate of 1.5 mL min−1 and the effluent was monitored at 350 nm. Good resolution was obtained with tR values of 2.069 and 5.174 min for Carbazochrome and Troxerutin, respectively. Method (B) is HPTLC-Densitometric method, using silica gel 60 F254 HPTLC plates and methanol:chloroform:ammonia (40:60:7, by volume) as a developing system. The bands were scanned at 350 nm. The proposed methods have been validated as per ICH guidelines and their linearity was evident in the ranges of 0.25–10 and 5–50 μg mL−1 for method (A) and 0.02–0.8 and 0.1–2 μg band−1 for method (B) for Carbazochrome and Troxerutin, respectively. The developed methods have been applied for the determination of the above mentioned drugs in their pharmaceutical formulation where no interference from the excipients has been detected. Statistical comparison of the results obtained by the developed methods and those obtained by the reported HPLC methods showed no significant difference between them. The developed methods are sensitive, accurate and precise and can be easily used for quality control analysis of the studied drugs. |
first_indexed | 2024-04-11T03:14:55Z |
format | Article |
id | doaj.art-673fbdb1244f48b890e4a1c1731772a8 |
institution | Directory Open Access Journal |
issn | 1110-0931 |
language | English |
last_indexed | 2024-04-11T03:14:55Z |
publishDate | 2016-06-01 |
publisher | Faculty of Pharmacy, Cairo University |
record_format | Article |
series | Bulletin of Faculty of Pharmacy Cairo University |
spelling | doaj.art-673fbdb1244f48b890e4a1c1731772a82023-01-02T10:44:58ZengFaculty of Pharmacy, Cairo UniversityBulletin of Faculty of Pharmacy Cairo University1110-09312016-06-01541677510.1016/j.bfopcu.2016.01.001Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methodsMaha Mohamed AbdelrahmanEglal Abdelhameed AbdelaleemNouruddin Wageih AliRaghda Abdelmoneim EmamTwo accurate, precise and sensitive RP-HPLC and HPTLC-Densitometric methods have been developed for the determination of Carbazochrome and Troxerutin in their binary mixture without previous separation. Method (A) is RP-HPLC which depended on isocratic elution using C18 column and mobile phase consisting of water containing (0.2% triethylamine (TEA), 1% tetrahydrofuran (THF)):methanol (65:35, by volume) at a flow rate of 1.5 mL min−1 and the effluent was monitored at 350 nm. Good resolution was obtained with tR values of 2.069 and 5.174 min for Carbazochrome and Troxerutin, respectively. Method (B) is HPTLC-Densitometric method, using silica gel 60 F254 HPTLC plates and methanol:chloroform:ammonia (40:60:7, by volume) as a developing system. The bands were scanned at 350 nm. The proposed methods have been validated as per ICH guidelines and their linearity was evident in the ranges of 0.25–10 and 5–50 μg mL−1 for method (A) and 0.02–0.8 and 0.1–2 μg band−1 for method (B) for Carbazochrome and Troxerutin, respectively. The developed methods have been applied for the determination of the above mentioned drugs in their pharmaceutical formulation where no interference from the excipients has been detected. Statistical comparison of the results obtained by the developed methods and those obtained by the reported HPLC methods showed no significant difference between them. The developed methods are sensitive, accurate and precise and can be easily used for quality control analysis of the studied drugs.http://www.sciencedirect.com/science/article/pii/S111009311600003XCarbazochromeTroxerutinRP-HPLCHPTLC-DensitometryPharmaceutical formulation |
spellingShingle | Maha Mohamed Abdelrahman Eglal Abdelhameed Abdelaleem Nouruddin Wageih Ali Raghda Abdelmoneim Emam Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods Bulletin of Faculty of Pharmacy Cairo University Carbazochrome Troxerutin RP-HPLC HPTLC-Densitometry Pharmaceutical formulation |
title | Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods |
title_full | Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods |
title_fullStr | Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods |
title_full_unstemmed | Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods |
title_short | Simultaneous determination of Carbazochrome and Troxerutin in their binary mixture by HPLC and HPTLC-Densitometric methods |
title_sort | simultaneous determination of carbazochrome and troxerutin in their binary mixture by hplc and hptlc densitometric methods |
topic | Carbazochrome Troxerutin RP-HPLC HPTLC-Densitometry Pharmaceutical formulation |
url | http://www.sciencedirect.com/science/article/pii/S111009311600003X |
work_keys_str_mv | AT mahamohamedabdelrahman simultaneousdeterminationofcarbazochromeandtroxerutinintheirbinarymixturebyhplcandhptlcdensitometricmethods AT eglalabdelhameedabdelaleem simultaneousdeterminationofcarbazochromeandtroxerutinintheirbinarymixturebyhplcandhptlcdensitometricmethods AT nouruddinwageihali simultaneousdeterminationofcarbazochromeandtroxerutinintheirbinarymixturebyhplcandhptlcdensitometricmethods AT raghdaabdelmoneimemam simultaneousdeterminationofcarbazochromeandtroxerutinintheirbinarymixturebyhplcandhptlcdensitometricmethods |