Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope
OBJECTIVE: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope. PATIENTS...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2022-01-01
|
Series: | Annals of Thoracic Medicine |
Subjects: | |
Online Access: | http://www.thoracicmedicine.org/article.asp?issn=1817-1737;year=2022;volume=17;issue=3;spage=151;epage=158;aulast=Guan |
_version_ | 1818196805799641088 |
---|---|
author | Shuhong Guan Jun Zhou Qiudi Zhang Qianqian Xu Xiong Xu Sujuan Zhang |
author_facet | Shuhong Guan Jun Zhou Qiudi Zhang Qianqian Xu Xiong Xu Sujuan Zhang |
author_sort | Shuhong Guan |
collection | DOAJ |
description | OBJECTIVE: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope.
PATIENTS AND METHODS: Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined.
RESULTS: A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group.
CONCLUSION: REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic. |
first_indexed | 2024-12-12T01:39:55Z |
format | Article |
id | doaj.art-677bc57ab6ea453eabd0ac56cde90912 |
institution | Directory Open Access Journal |
issn | 1817-1737 1998-3557 |
language | English |
last_indexed | 2024-12-12T01:39:55Z |
publishDate | 2022-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Annals of Thoracic Medicine |
spelling | doaj.art-677bc57ab6ea453eabd0ac56cde909122022-12-22T00:42:44ZengWolters Kluwer Medknow PublicationsAnnals of Thoracic Medicine1817-17371998-35572022-01-0117315115810.4103/atm.atm_495_21Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscopeShuhong GuanJun ZhouQiudi ZhangQianqian XuXiong XuSujuan ZhangOBJECTIVE: This study aims to explore the diagnostic values of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance (rEBUS-D-TBLB) measurement and with guide sheath (rEBUS-GS-TBLB) for peripheral pulmonary lesions (PPLs) with a diameter ≥3 cm by thin bronchoscope. PATIENTS AND METHODS: Six hundred and three patients with PPL (diameter ≥3 cm) were enrolled in this study. The subjects were divided into the rEBUS-D-TBLB and rEBUS-GS-TBLB groups by the random number table method. Patients were assigned to undergo rEBUS-D-TBLB or rEBUS-GS-TBLB, respectively. The histopathology, positive diagnosis rates, duration of the procedure, and postoperative adverse effects between the two groups were examined. RESULTS: A total of 569 patients were included in this study according to the inclusion and exclusion criteria, with 282 cases in the rEBUS-D-TBLB group and 287 cases in the rEBUS-GS-TBLB group. For malignant diseases, the positive diagnosis rates of PPL in the outer/inner-middle lung bands and the right-upper/-lower lung lobes by rEBUS-D-TBLB were noninferior to those of rEBUS-GS-TBLB. The duration of the procedure of rEBUS-D-TBLB was longer than that of rEBUS-GS-TBLB. There were 14 cases of hemorrhage >50 mL, 1 case of postoperative chest pain in the rEBUS-D-TBLB group, and 3 cases of hemorrhage >50 mL in the rEBUS-GS-TBLB group. CONCLUSION: REBUS-D-TBLB by thin bronchoscope has a high diagnostic value for PPL with a diameter ≥3 cm, which may be considered a useful alternative for rEBUS-GS-TBLB in the clinic.http://www.thoracicmedicine.org/article.asp?issn=1817-1737;year=2022;volume=17;issue=3;spage=151;epage=158;aulast=Guanbronchoscopydistanceguide sheathperipheral pulmonary lesionradial endobronchial ultrasound |
spellingShingle | Shuhong Guan Jun Zhou Qiudi Zhang Qianqian Xu Xiong Xu Sujuan Zhang Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope Annals of Thoracic Medicine bronchoscopy distance guide sheath peripheral pulmonary lesion radial endobronchial ultrasound |
title | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_full | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_fullStr | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_full_unstemmed | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_short | Comparison of radial endobronchial ultrasound-guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
title_sort | comparison of radial endobronchial ultrasound guided transbronchial lung biopsy with distance measurement versus with guide sheath in diagnosing peripheral pulmonary lesions with a diameter ≥3 cm by thin bronchoscope |
topic | bronchoscopy distance guide sheath peripheral pulmonary lesion radial endobronchial ultrasound |
url | http://www.thoracicmedicine.org/article.asp?issn=1817-1737;year=2022;volume=17;issue=3;spage=151;epage=158;aulast=Guan |
work_keys_str_mv | AT shuhongguan comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT junzhou comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT qiudizhang comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT qianqianxu comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT xiongxu comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope AT sujuanzhang comparisonofradialendobronchialultrasoundguidedtransbronchiallungbiopsywithdistancemeasurementversuswithguidesheathindiagnosingperipheralpulmonarylesionswithadiameter3cmbythinbronchoscope |