A comparison of ventricular volume and linear indices in predicting shunt dependence in aneurysmal subarachnoid hemorrhage

Background: Guidelines for determining shunt dependence after aneurysmal subarachnoid hemorrhage (aSAH) remain unclear. We previously demonstrated change in ventricular volume (VV) between head CT scans taken pre- and post-EVD clamping was predictive of shunt dependence in aSAH. We sought to compare...

Full description

Bibliographic Details
Main Authors: Haley K. Talbot-Stetsko, Todd C. Hollon, Cormac O. Maher, Aditya S. Pandey, Siri Sahib S. Khalsa
Format: Article
Language:English
Published: Elsevier 2023-07-01
Series:World Neurosurgery: X
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2590139723000303
Description
Summary:Background: Guidelines for determining shunt dependence after aneurysmal subarachnoid hemorrhage (aSAH) remain unclear. We previously demonstrated change in ventricular volume (VV) between head CT scans taken pre- and post-EVD clamping was predictive of shunt dependence in aSAH. We sought to compare the predictive value of this measure to more commonly used linear indices. Methods: We retrospectively analyzed images of 68 patients treated for aSAH who required EVD placement and underwent one EVD weaning trial, 34 of whom underwent shunt placement. We utilized an in-house MATLAB program to analyze VV and supratentorial VV (sVV) in head CT scans obtained before and after EVD clamping. Evans' index (EI), frontal and occipital horn ratio (FOHR), Huckman's measurement, minimum lateral ventricular width (LV-Min.), and lateral ventricle body span (LV-Body) were measured using digital calipers in PACS. Receiver operating curves (ROC) were generated. Results: Area under the ROC curves (AUC) for the change in VV, sVV, EI, FOHR, Huckman's, LV-Min., and LV-Body with clamping were 0.84, 0.84, 0.65, 0.71.0.69, 0.67, and 0.66, respectively. AUC for post-clamp scan measurements were 0.75, 0.75, 0.74, 0.72, 0.72, 0.70, and 0.75, respectively. Conclusion: VV change with EVD clamping was more predictive of shunt dependence in aSAH than change in linear measurements with clamping and all post-clamp measurements. Measurement of ventricular size on serial imaging with volumetrics or linear indices utilizing multidimensional data points may therefore be a more robust metric than unidimensional linear indices in predicting shunt dependence in this cohort. Prospective studies are needed for validation.
ISSN:2590-1397