Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.

Enumeration of CD4+ T lymphocytes is important for pre-ART disease staging and screening for opportunistic infections, however access to CD4 testing in resource limited settings is poor. Point of care (POC) technologies can facilitate improved access to CD4 testing. We evaluated the analytical perfo...

Full description

Bibliographic Details
Main Authors: Azure Tariro Makadzange, Carola Bogezi, Kathryn Boyd, Anesu Gumbo, Dorinda Mukura, Allen Matubu, Chiratidzo Ellen Ndhlovu
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4936750?pdf=render
_version_ 1818520018434916352
author Azure Tariro Makadzange
Carola Bogezi
Kathryn Boyd
Anesu Gumbo
Dorinda Mukura
Allen Matubu
Chiratidzo Ellen Ndhlovu
author_facet Azure Tariro Makadzange
Carola Bogezi
Kathryn Boyd
Anesu Gumbo
Dorinda Mukura
Allen Matubu
Chiratidzo Ellen Ndhlovu
author_sort Azure Tariro Makadzange
collection DOAJ
description Enumeration of CD4+ T lymphocytes is important for pre-ART disease staging and screening for opportunistic infections, however access to CD4 testing in resource limited settings is poor. Point of care (POC) technologies can facilitate improved access to CD4 testing. We evaluated the analytical performance of a novel POC device the FACSPresto compared to the FACSCalibur as a reference standard and to the PIMA, a POC device in widespread use in sub-Saharan Africa.Specimens were obtained from 253 HIV infected adults. Venous blood samples were analyzed on the FACSPresto and the FACSCalibur, in a subset of 41 samples additional analysis was done on the PIMA.The absolute CD4 count results obtained on the FACSPresto were comparable to those on the FACSCalibur with low absolute (9.5cells/μl) and relative bias (3.2%). Bias in CD4% values was also low (1.06%) with a relative bias of 4.9%. The sensitivity was lower at a CD4 count threshold of ≤350cells/μl compared with ≤500cells/μl (84.9% vs. 92.8%) resulting in a high upward misclassification rate at low CD4 counts. Specificity at thresholds of ≤350cells/μl and ≤500cells/μl were 96.6% and 96.8% respectively. The PIMA had a high absolute (-68.6cells/μl) and relative bias (-10.5%) when compared with the FACSCalibur. At thresholds of ≤350cells/μl and ≤500cells/μl the sensitivity was 100% and 95.5% respectively; specificity was 85.7% and 84.2% respectively. The coefficients of repeatability were 4.13%, 5.29% and 9.8% respectively.The analytic performance of the FACSPresto against the reference standard was very good with better agreement and precision than the PIMA. The FACSPresto had comparable sensitivity at a threshold of 500 cells/μl and better specificity than the PIMA. However the FACSPresto showed reduced sensitivity at low CD4 count thresholds.The FACSPresto can be reliably used as a POC device for enumerating absolute CD4 count and CD4% values.
first_indexed 2024-12-11T01:31:48Z
format Article
id doaj.art-679601cd7a6b4de8929e19f5a09f2453
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-11T01:31:48Z
publishDate 2016-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-679601cd7a6b4de8929e19f5a09f24532022-12-22T01:25:21ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01117e015754610.1371/journal.pone.0157546Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.Azure Tariro MakadzangeCarola BogeziKathryn BoydAnesu GumboDorinda MukuraAllen MatubuChiratidzo Ellen NdhlovuEnumeration of CD4+ T lymphocytes is important for pre-ART disease staging and screening for opportunistic infections, however access to CD4 testing in resource limited settings is poor. Point of care (POC) technologies can facilitate improved access to CD4 testing. We evaluated the analytical performance of a novel POC device the FACSPresto compared to the FACSCalibur as a reference standard and to the PIMA, a POC device in widespread use in sub-Saharan Africa.Specimens were obtained from 253 HIV infected adults. Venous blood samples were analyzed on the FACSPresto and the FACSCalibur, in a subset of 41 samples additional analysis was done on the PIMA.The absolute CD4 count results obtained on the FACSPresto were comparable to those on the FACSCalibur with low absolute (9.5cells/μl) and relative bias (3.2%). Bias in CD4% values was also low (1.06%) with a relative bias of 4.9%. The sensitivity was lower at a CD4 count threshold of ≤350cells/μl compared with ≤500cells/μl (84.9% vs. 92.8%) resulting in a high upward misclassification rate at low CD4 counts. Specificity at thresholds of ≤350cells/μl and ≤500cells/μl were 96.6% and 96.8% respectively. The PIMA had a high absolute (-68.6cells/μl) and relative bias (-10.5%) when compared with the FACSCalibur. At thresholds of ≤350cells/μl and ≤500cells/μl the sensitivity was 100% and 95.5% respectively; specificity was 85.7% and 84.2% respectively. The coefficients of repeatability were 4.13%, 5.29% and 9.8% respectively.The analytic performance of the FACSPresto against the reference standard was very good with better agreement and precision than the PIMA. The FACSPresto had comparable sensitivity at a threshold of 500 cells/μl and better specificity than the PIMA. However the FACSPresto showed reduced sensitivity at low CD4 count thresholds.The FACSPresto can be reliably used as a POC device for enumerating absolute CD4 count and CD4% values.http://europepmc.org/articles/PMC4936750?pdf=render
spellingShingle Azure Tariro Makadzange
Carola Bogezi
Kathryn Boyd
Anesu Gumbo
Dorinda Mukura
Allen Matubu
Chiratidzo Ellen Ndhlovu
Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.
PLoS ONE
title Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.
title_full Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.
title_fullStr Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.
title_full_unstemmed Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.
title_short Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection.
title_sort evaluation of the facspresto a new point of care device for the enumeration of cd4 and absolute cd4 t cell counts in hiv infection
url http://europepmc.org/articles/PMC4936750?pdf=render
work_keys_str_mv AT azuretariromakadzange evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection
AT carolabogezi evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection
AT kathrynboyd evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection
AT anesugumbo evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection
AT dorindamukura evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection
AT allenmatubu evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection
AT chiratidzoellenndhlovu evaluationofthefacsprestoanewpointofcaredevicefortheenumerationofcd4andabsolutecd4tcellcountsinhivinfection