A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion be...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2022-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://www.matec-conferences.org/articles/matecconf/pdf/2022/11/matecconf_iccrrr22_02025.pdf |
_version_ | 1797807583172493312 |
---|---|
author | Nguyen Thi-Thu Trang François Raoul Vu Tru Ngoc Carcasses Myriam |
author_facet | Nguyen Thi-Thu Trang François Raoul Vu Tru Ngoc Carcasses Myriam |
author_sort | Nguyen Thi-Thu Trang |
collection | DOAJ |
description | Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion between first de-passivated layer closed to the concrete surface and deeper layers still passivated. The present paper compares the uniform corrosion density and the galvanic corrosion density for concrete samples made with two different type of cements. CEM III cement despite their higher susceptibility to carbonation show a significant lower galvanic corrosion density, which would lead to a significant increase in the service life of RC structures, exposed to carbonation. |
first_indexed | 2024-03-13T06:24:44Z |
format | Article |
id | doaj.art-67be79e670084f6785652ecfa3968872 |
institution | Directory Open Access Journal |
issn | 2261-236X |
language | English |
last_indexed | 2024-03-13T06:24:44Z |
publishDate | 2022-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | MATEC Web of Conferences |
spelling | doaj.art-67be79e670084f6785652ecfa39688722023-06-09T09:28:13ZengEDP SciencesMATEC Web of Conferences2261-236X2022-01-013640202510.1051/matecconf/202236402025matecconf_iccrrr22_02025A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concreteNguyen Thi-Thu Trang0François Raoul1Vu Tru Ngoc2Carcasses Myriam3LMDC, INSA, UPS, Université de ToulouseLMDC, INSA, UPS, Université de ToulouseNational University of Civil EngineeringLMDC, INSA, UPS, Université de ToulouseCarbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion between first de-passivated layer closed to the concrete surface and deeper layers still passivated. The present paper compares the uniform corrosion density and the galvanic corrosion density for concrete samples made with two different type of cements. CEM III cement despite their higher susceptibility to carbonation show a significant lower galvanic corrosion density, which would lead to a significant increase in the service life of RC structures, exposed to carbonation.https://www.matec-conferences.org/articles/matecconf/pdf/2022/11/matecconf_iccrrr22_02025.pdf |
spellingShingle | Nguyen Thi-Thu Trang François Raoul Vu Tru Ngoc Carcasses Myriam A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete MATEC Web of Conferences |
title | A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete |
title_full | A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete |
title_fullStr | A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete |
title_full_unstemmed | A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete |
title_short | A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete |
title_sort | comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete |
url | https://www.matec-conferences.org/articles/matecconf/pdf/2022/11/matecconf_iccrrr22_02025.pdf |
work_keys_str_mv | AT nguyenthithutrang acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT francoisraoul acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT vutrungoc acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT carcassesmyriam acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT nguyenthithutrang comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT francoisraoul comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT vutrungoc comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete AT carcassesmyriam comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete |