A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete

Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion be...

Full description

Bibliographic Details
Main Authors: Nguyen Thi-Thu Trang, François Raoul, Vu Tru Ngoc, Carcasses Myriam
Format: Article
Language:English
Published: EDP Sciences 2022-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2022/11/matecconf_iccrrr22_02025.pdf
_version_ 1797807583172493312
author Nguyen Thi-Thu Trang
François Raoul
Vu Tru Ngoc
Carcasses Myriam
author_facet Nguyen Thi-Thu Trang
François Raoul
Vu Tru Ngoc
Carcasses Myriam
author_sort Nguyen Thi-Thu Trang
collection DOAJ
description Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion between first de-passivated layer closed to the concrete surface and deeper layers still passivated. The present paper compares the uniform corrosion density and the galvanic corrosion density for concrete samples made with two different type of cements. CEM III cement despite their higher susceptibility to carbonation show a significant lower galvanic corrosion density, which would lead to a significant increase in the service life of RC structures, exposed to carbonation.
first_indexed 2024-03-13T06:24:44Z
format Article
id doaj.art-67be79e670084f6785652ecfa3968872
institution Directory Open Access Journal
issn 2261-236X
language English
last_indexed 2024-03-13T06:24:44Z
publishDate 2022-01-01
publisher EDP Sciences
record_format Article
series MATEC Web of Conferences
spelling doaj.art-67be79e670084f6785652ecfa39688722023-06-09T09:28:13ZengEDP SciencesMATEC Web of Conferences2261-236X2022-01-013640202510.1051/matecconf/202236402025matecconf_iccrrr22_02025A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concreteNguyen Thi-Thu Trang0François Raoul1Vu Tru Ngoc2Carcasses Myriam3LMDC, INSA, UPS, Université de ToulouseLMDC, INSA, UPS, Université de ToulouseNational University of Civil EngineeringLMDC, INSA, UPS, Université de ToulouseCarbonation-induced corrosion is usually considered in uniform or generalized corrosion. This is true for small laboratory samples but not necessary the case for real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic corrosion between first de-passivated layer closed to the concrete surface and deeper layers still passivated. The present paper compares the uniform corrosion density and the galvanic corrosion density for concrete samples made with two different type of cements. CEM III cement despite their higher susceptibility to carbonation show a significant lower galvanic corrosion density, which would lead to a significant increase in the service life of RC structures, exposed to carbonation.https://www.matec-conferences.org/articles/matecconf/pdf/2022/11/matecconf_iccrrr22_02025.pdf
spellingShingle Nguyen Thi-Thu Trang
François Raoul
Vu Tru Ngoc
Carcasses Myriam
A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
MATEC Web of Conferences
title A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
title_full A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
title_fullStr A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
title_full_unstemmed A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
title_short A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
title_sort comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
url https://www.matec-conferences.org/articles/matecconf/pdf/2022/11/matecconf_iccrrr22_02025.pdf
work_keys_str_mv AT nguyenthithutrang acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT francoisraoul acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT vutrungoc acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT carcassesmyriam acomparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT nguyenthithutrang comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT francoisraoul comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT vutrungoc comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete
AT carcassesmyriam comparisonbetweenuniformandgalvaniccorrosionrateincarbonationinducedcorrosionofreinforcedconcrete