Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract

An aptamer-based electrochemical biosensor was successfully developed and applied in the rapid detection of pathogenic Escherichia coli (E. coli) in licorice extract. The thiolated capture probes were firstly immobilized on a gold electrode, and then the biotinylated aptamer probes for E. coli were...

Full description

Bibliographic Details
Main Authors: Haixia Wang, Yuwen Zhao, Songtao Bie, Tongchuan Suo, Guangcheng Jia, Boshi Liu, Ruiping Ye, Zheng Li
Format: Article
Language:English
Published: MDPI AG 2019-01-01
Series:Applied Sciences
Subjects:
Online Access:http://www.mdpi.com/2076-3417/9/2/295
_version_ 1818411802214531072
author Haixia Wang
Yuwen Zhao
Songtao Bie
Tongchuan Suo
Guangcheng Jia
Boshi Liu
Ruiping Ye
Zheng Li
author_facet Haixia Wang
Yuwen Zhao
Songtao Bie
Tongchuan Suo
Guangcheng Jia
Boshi Liu
Ruiping Ye
Zheng Li
author_sort Haixia Wang
collection DOAJ
description An aptamer-based electrochemical biosensor was successfully developed and applied in the rapid detection of pathogenic Escherichia coli (E. coli) in licorice extract. The thiolated capture probes were firstly immobilized on a gold electrode, and then the biotinylated aptamer probes for E. coli were introduced by hybridization with the capture probes. Due to the stronger interaction between the aptamer and the E. coli, a part of the biotinylated aptamers will dissociate from the capture probes in the presence of E. coli. The residual biotinylated aptamer probes can quantitatively bind with streptavidin-alkaline phosphatase. Subsequently, α-naphthyl phosphate substrate was catalytically hydrolyzed to generate electrochemical response, which could be recorded by a differential pulse voltammetry. The dependence of the peak current on the logarithm of E. coli concentration in the range from 5.0 × 102 colony forming units (CFU)/mL to 5.0 × 107 CFU/mL exhibited a linear trend with a detection limit of 80 CFU/mL. The relative standard deviation of 5 successive scans was 5.3%, 4.5% and 1.1% for 5.0 × 102, 5.0 × 105 and 5.0 × 107 CFU/mL E. coli, respectively. In the detection of the licorice extract samples, the results obtained from the proposed strategy and traditional culture counting method were close to each other, but the time consumption was only ~1/30 compared with the traditional method. These results demonstrate that the designed biosensor can be potentially utilized for rapid microbial examination in traditional Chinese medicine and relevant fields.
first_indexed 2024-12-14T10:37:12Z
format Article
id doaj.art-67ceec529fb348f28a5250b8ba10e28f
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-12-14T10:37:12Z
publishDate 2019-01-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-67ceec529fb348f28a5250b8ba10e28f2022-12-21T23:05:53ZengMDPI AGApplied Sciences2076-34172019-01-019229510.3390/app9020295app9020295Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice ExtractHaixia Wang0Yuwen Zhao1Songtao Bie2Tongchuan Suo3Guangcheng Jia4Boshi Liu5Ruiping Ye6Zheng Li7College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaCollege of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaCollege of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaCollege of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaTasly Pharmaceutical Group Co., Ltd., Tianjin 300410, ChinaCollege of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaCollege of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaCollege of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 300193, ChinaAn aptamer-based electrochemical biosensor was successfully developed and applied in the rapid detection of pathogenic Escherichia coli (E. coli) in licorice extract. The thiolated capture probes were firstly immobilized on a gold electrode, and then the biotinylated aptamer probes for E. coli were introduced by hybridization with the capture probes. Due to the stronger interaction between the aptamer and the E. coli, a part of the biotinylated aptamers will dissociate from the capture probes in the presence of E. coli. The residual biotinylated aptamer probes can quantitatively bind with streptavidin-alkaline phosphatase. Subsequently, α-naphthyl phosphate substrate was catalytically hydrolyzed to generate electrochemical response, which could be recorded by a differential pulse voltammetry. The dependence of the peak current on the logarithm of E. coli concentration in the range from 5.0 × 102 colony forming units (CFU)/mL to 5.0 × 107 CFU/mL exhibited a linear trend with a detection limit of 80 CFU/mL. The relative standard deviation of 5 successive scans was 5.3%, 4.5% and 1.1% for 5.0 × 102, 5.0 × 105 and 5.0 × 107 CFU/mL E. coli, respectively. In the detection of the licorice extract samples, the results obtained from the proposed strategy and traditional culture counting method were close to each other, but the time consumption was only ~1/30 compared with the traditional method. These results demonstrate that the designed biosensor can be potentially utilized for rapid microbial examination in traditional Chinese medicine and relevant fields.http://www.mdpi.com/2076-3417/9/2/295aptamerelectrochemicalEscherichia colibiosensorlicorice
spellingShingle Haixia Wang
Yuwen Zhao
Songtao Bie
Tongchuan Suo
Guangcheng Jia
Boshi Liu
Ruiping Ye
Zheng Li
Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract
Applied Sciences
aptamer
electrochemical
Escherichia coli
biosensor
licorice
title Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract
title_full Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract
title_fullStr Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract
title_full_unstemmed Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract
title_short Development of an Electrochemical Biosensor for Rapid and Effective Detection of Pathogenic Escherichia coli in Licorice Extract
title_sort development of an electrochemical biosensor for rapid and effective detection of pathogenic escherichia coli in licorice extract
topic aptamer
electrochemical
Escherichia coli
biosensor
licorice
url http://www.mdpi.com/2076-3417/9/2/295
work_keys_str_mv AT haixiawang developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT yuwenzhao developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT songtaobie developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT tongchuansuo developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT guangchengjia developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT boshiliu developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT ruipingye developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract
AT zhengli developmentofanelectrochemicalbiosensorforrapidandeffectivedetectionofpathogenicescherichiacoliinlicoriceextract