CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing

Background and purpose — The most frequent cause of arthroplasty failure is aseptic loosening—often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone–implant interface. We an...

Full description

Bibliographic Details
Main Authors: Felix Hopf, Peter Thomas, Stefan Sesselmann, Marc N Thomsen, Maximilian Hopf, Johannes Hopf, Manfred G Krukemeyer, Herbert Resch, Veit Krenn
Format: Article
Language:English
Published: Medical Journals Sweden 2017-11-01
Series:Acta Orthopaedica
Online Access:http://dx.doi.org/10.1080/17453674.2017.1362774
_version_ 1828128249600802816
author Felix Hopf
Peter Thomas
Stefan Sesselmann
Marc N Thomsen
Maximilian Hopf
Johannes Hopf
Manfred G Krukemeyer
Herbert Resch
Veit Krenn
author_facet Felix Hopf
Peter Thomas
Stefan Sesselmann
Marc N Thomsen
Maximilian Hopf
Johannes Hopf
Manfred G Krukemeyer
Herbert Resch
Veit Krenn
author_sort Felix Hopf
collection DOAJ
description Background and purpose — The most frequent cause of arthroplasty failure is aseptic loosening—often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone–implant interface. We analyzed CD3 quantities in SLIM depending on articulating materials and possible influences of proven material allergies on CD3 quantities. Patients and methods — 222 SLIM probes were obtained from revision surgeries of loosened hip and knee arthroplasties. SLIM cases were categorized according to the SLIM-consensus classification and to the particle algorithm. The CD3 quantities were analyzed immunohistochemically, quantified, and correlated to the particle types. Results — Metal–metal pairings showed the highest CD3 quantities (mean 1,367 counted cells). CD3 quantities of metal–polyethylene (mean 243), ceramic–polyethylene (mean 182), and ceramic–ceramic pairings (mean 124) were significantly smaller. Patients with contact allergy to implant materials had high but not statistically significantly higher CD3 quantities than patients without allergies. For objective assessment of the CD3 response as result of a pronounced inflammatory reaction with high lymphocytosis (adverse reaction), a defined CD3 quantity per high power field was established, the “CD3 focus score” (447 cells/0.3 mm2, sensitivity 0.92; specificity 0.90; positive predictive value 0.71; negative predictive value 0.98). Interpretation — The high CD3 quantities for metal–metal pairings may be interpreted as substrate for previously described adverse reactions that cause severe peri-implant tissue destruction and SLIM formation. It remains unclear whether the low CD3 quantities with only slight differences in the various non-metal–metal pairings and documented contact allergies to implant materials have a direct pathogenetic relevance.
first_indexed 2024-04-11T16:01:26Z
format Article
id doaj.art-6835ba4d87a245809676644a63f107a6
institution Directory Open Access Journal
issn 1745-3674
1745-3682
language English
last_indexed 2024-04-11T16:01:26Z
publishDate 2017-11-01
publisher Medical Journals Sweden
record_format Article
series Acta Orthopaedica
spelling doaj.art-6835ba4d87a245809676644a63f107a62022-12-22T04:14:56ZengMedical Journals SwedenActa Orthopaedica1745-36741745-36822017-11-0188664264810.1080/17453674.2017.13627741362774CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairingFelix Hopf0Peter Thomas1Stefan Sesselmann2Marc N Thomsen3Maximilian Hopf4Johannes Hopf5Manfred G Krukemeyer6Herbert Resch7Veit Krenn8Center for Histopathology and Molecular PathologyLudwig-Maximilians-University (LMU)Friedrich-Alexander-University of Erlangen-NurembergKlinikum Mittelbaden Baden-Baden BalgCenter for Histopathology and Molecular PathologyJohannes Gutenberg UniversityParacelsus-Kliniken Deutschland GmbHUniversity Hospital for Trauma Surgery and Sports TraumatologyCenter for Histopathology and Molecular PathologyBackground and purpose — The most frequent cause of arthroplasty failure is aseptic loosening—often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone–implant interface. We analyzed CD3 quantities in SLIM depending on articulating materials and possible influences of proven material allergies on CD3 quantities. Patients and methods — 222 SLIM probes were obtained from revision surgeries of loosened hip and knee arthroplasties. SLIM cases were categorized according to the SLIM-consensus classification and to the particle algorithm. The CD3 quantities were analyzed immunohistochemically, quantified, and correlated to the particle types. Results — Metal–metal pairings showed the highest CD3 quantities (mean 1,367 counted cells). CD3 quantities of metal–polyethylene (mean 243), ceramic–polyethylene (mean 182), and ceramic–ceramic pairings (mean 124) were significantly smaller. Patients with contact allergy to implant materials had high but not statistically significantly higher CD3 quantities than patients without allergies. For objective assessment of the CD3 response as result of a pronounced inflammatory reaction with high lymphocytosis (adverse reaction), a defined CD3 quantity per high power field was established, the “CD3 focus score” (447 cells/0.3 mm2, sensitivity 0.92; specificity 0.90; positive predictive value 0.71; negative predictive value 0.98). Interpretation — The high CD3 quantities for metal–metal pairings may be interpreted as substrate for previously described adverse reactions that cause severe peri-implant tissue destruction and SLIM formation. It remains unclear whether the low CD3 quantities with only slight differences in the various non-metal–metal pairings and documented contact allergies to implant materials have a direct pathogenetic relevance.http://dx.doi.org/10.1080/17453674.2017.1362774
spellingShingle Felix Hopf
Peter Thomas
Stefan Sesselmann
Marc N Thomsen
Maximilian Hopf
Johannes Hopf
Manfred G Krukemeyer
Herbert Resch
Veit Krenn
CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
Acta Orthopaedica
title CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
title_full CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
title_fullStr CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
title_full_unstemmed CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
title_short CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
title_sort cd3 lymphocytosis in the peri implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing
url http://dx.doi.org/10.1080/17453674.2017.1362774
work_keys_str_mv AT felixhopf cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT peterthomas cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT stefansesselmann cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT marcnthomsen cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT maximilianhopf cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT johanneshopf cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT manfredgkrukemeyer cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT herbertresch cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing
AT veitkrenn cd3lymphocytosisintheperiimplantmembraneof222loosenedjointendoprosthesesdependsonthetribologicalpairing