Effect of saliva contamination on bond strength witha hydrophilic composite resin
OBJECTIVE: To evaluate the influence of saliva contamination on the bond strength of metallic brackets bonded to enamel with hydrophilic resin composite. METHODS: Eighty premolars were randomly divided into 4 groups (n = 20) according to bonding material and contamination: G1) bonded with Transbond...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dental Press Editora
2013-02-01
|
Series: | Dental Press Journal of Orthodontics |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100015 |
_version_ | 1818143173061378048 |
---|---|
author | Mauren Bitencourt Deprá Josiane Xavier de Almeida Taís de Morais Alves da Cunha Luis Filipe Siu Lon Luciana Borges Retamoso Orlando Motohiro Tanaka |
author_facet | Mauren Bitencourt Deprá Josiane Xavier de Almeida Taís de Morais Alves da Cunha Luis Filipe Siu Lon Luciana Borges Retamoso Orlando Motohiro Tanaka |
author_sort | Mauren Bitencourt Deprá |
collection | DOAJ |
description | OBJECTIVE: To evaluate the influence of saliva contamination on the bond strength of metallic brackets bonded to enamel with hydrophilic resin composite. METHODS: Eighty premolars were randomly divided into 4 groups (n = 20) according to bonding material and contamination: G1) bonded with Transbond XT with no saliva contamination, G2) bonded with Transbond XT with saliva contamination, G3) bonded with Transbond Plus Color Change with no saliva contamination and G4) bonded with Transbond Plus Color Change with saliva contamination. The results were statistically analyzed (ANOVA/Tukey). RESULTS: The means and standard deviations (MPa) were: G1)10.15 ± 3.75; G2) 6.8 ± 2.54; G3) 9.3 ± 3.36; G4) 8.3 ± 2.95. The adhesive remnant index (ARI) ranged between 0 and 1 in G1 and G4. In G2 there was a prevalence of score 0 and similar ARI distribution in G3. CONCLUSION: Saliva contamination reduced bond strength when Transbond XT hydrophobic resin composite was used. However, the hydrophilic resin Transbond Plus Color Change was not affected by the contamination.<br>OBJETIVO: avaliar a influência da contaminação por saliva na resistência de união de braquetes metálicos colados ao esmalte com um compósito resinoso hidrofílico. MÉTODOS: oitenta pré-molares foram divididos aleatoriamente em quatro grupos (n=20), de acordo com o material de colagem e a presença de contaminação - G1) colagem com Transbond XT na ausência de contaminação; G2) colagem com Transbond XT na presença de contaminação; G3) colagem com Transbond Plus Color Change na ausência de contaminação; G4) colagem com Transbond Plus Color Change na presença de contaminação. Os resultados foram tratados estatisticamente (ANOVA/Tukey). RESULTADOS: as médias e desvios-padrão (MPa) foram G1 = 10,15 ± 3,75; G2 = 6,8 ± 2,54; G3 = 9,3 ± 3,36; G4 = 8,3 ± 2,95. O índice de adesivo remanescente (IAR) variou entre 0 e 1 no G1 e no G4; no G2, houve predomínio do escore 0 e distribuição similar no G3. CONCLUSÃO: a contaminação por saliva reduziu a resistência de união no grupo que usou a resina hidrofóbica Transbond XT. Por outro lado, a resina hidrofílica Transbond Plus Color Change não foi influenciada pela contaminação. |
first_indexed | 2024-12-11T11:27:27Z |
format | Article |
id | doaj.art-685749ef6ca349029015d78132ab95bf |
institution | Directory Open Access Journal |
issn | 2176-9451 2177-6709 |
language | English |
last_indexed | 2024-12-11T11:27:27Z |
publishDate | 2013-02-01 |
publisher | Dental Press Editora |
record_format | Article |
series | Dental Press Journal of Orthodontics |
spelling | doaj.art-685749ef6ca349029015d78132ab95bf2022-12-22T01:08:59ZengDental Press EditoraDental Press Journal of Orthodontics2176-94512177-67092013-02-011816368Effect of saliva contamination on bond strength witha hydrophilic composite resinMauren Bitencourt DepráJosiane Xavier de AlmeidaTaís de Morais Alves da CunhaLuis Filipe Siu LonLuciana Borges RetamosoOrlando Motohiro TanakaOBJECTIVE: To evaluate the influence of saliva contamination on the bond strength of metallic brackets bonded to enamel with hydrophilic resin composite. METHODS: Eighty premolars were randomly divided into 4 groups (n = 20) according to bonding material and contamination: G1) bonded with Transbond XT with no saliva contamination, G2) bonded with Transbond XT with saliva contamination, G3) bonded with Transbond Plus Color Change with no saliva contamination and G4) bonded with Transbond Plus Color Change with saliva contamination. The results were statistically analyzed (ANOVA/Tukey). RESULTS: The means and standard deviations (MPa) were: G1)10.15 ± 3.75; G2) 6.8 ± 2.54; G3) 9.3 ± 3.36; G4) 8.3 ± 2.95. The adhesive remnant index (ARI) ranged between 0 and 1 in G1 and G4. In G2 there was a prevalence of score 0 and similar ARI distribution in G3. CONCLUSION: Saliva contamination reduced bond strength when Transbond XT hydrophobic resin composite was used. However, the hydrophilic resin Transbond Plus Color Change was not affected by the contamination.<br>OBJETIVO: avaliar a influência da contaminação por saliva na resistência de união de braquetes metálicos colados ao esmalte com um compósito resinoso hidrofílico. MÉTODOS: oitenta pré-molares foram divididos aleatoriamente em quatro grupos (n=20), de acordo com o material de colagem e a presença de contaminação - G1) colagem com Transbond XT na ausência de contaminação; G2) colagem com Transbond XT na presença de contaminação; G3) colagem com Transbond Plus Color Change na ausência de contaminação; G4) colagem com Transbond Plus Color Change na presença de contaminação. Os resultados foram tratados estatisticamente (ANOVA/Tukey). RESULTADOS: as médias e desvios-padrão (MPa) foram G1 = 10,15 ± 3,75; G2 = 6,8 ± 2,54; G3 = 9,3 ± 3,36; G4 = 8,3 ± 2,95. O índice de adesivo remanescente (IAR) variou entre 0 e 1 no G1 e no G4; no G2, houve predomínio do escore 0 e distribuição similar no G3. CONCLUSÃO: a contaminação por saliva reduziu a resistência de união no grupo que usou a resina hidrofóbica Transbond XT. Por outro lado, a resina hidrofílica Transbond Plus Color Change não foi influenciada pela contaminação.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100015SalivaBraquetes ortodônticosResistência ao cisalhamentoAdesivosSalivaOrthodontic bracketsBond strengthAdhesives |
spellingShingle | Mauren Bitencourt Deprá Josiane Xavier de Almeida Taís de Morais Alves da Cunha Luis Filipe Siu Lon Luciana Borges Retamoso Orlando Motohiro Tanaka Effect of saliva contamination on bond strength witha hydrophilic composite resin Dental Press Journal of Orthodontics Saliva Braquetes ortodônticos Resistência ao cisalhamento Adesivos Saliva Orthodontic brackets Bond strength Adhesives |
title | Effect of saliva contamination on bond strength witha hydrophilic composite resin |
title_full | Effect of saliva contamination on bond strength witha hydrophilic composite resin |
title_fullStr | Effect of saliva contamination on bond strength witha hydrophilic composite resin |
title_full_unstemmed | Effect of saliva contamination on bond strength witha hydrophilic composite resin |
title_short | Effect of saliva contamination on bond strength witha hydrophilic composite resin |
title_sort | effect of saliva contamination on bond strength witha hydrophilic composite resin |
topic | Saliva Braquetes ortodônticos Resistência ao cisalhamento Adesivos Saliva Orthodontic brackets Bond strength Adhesives |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000100015 |
work_keys_str_mv | AT maurenbitencourtdepra effectofsalivacontaminationonbondstrengthwithahydrophiliccompositeresin AT josianexavierdealmeida effectofsalivacontaminationonbondstrengthwithahydrophiliccompositeresin AT taisdemoraisalvesdacunha effectofsalivacontaminationonbondstrengthwithahydrophiliccompositeresin AT luisfilipesiulon effectofsalivacontaminationonbondstrengthwithahydrophiliccompositeresin AT lucianaborgesretamoso effectofsalivacontaminationonbondstrengthwithahydrophiliccompositeresin AT orlandomotohirotanaka effectofsalivacontaminationonbondstrengthwithahydrophiliccompositeresin |