Global longitudinal strain: a useful everyday measurement?

Herceptin (Trastuzumab) is a widely used and effective drug for the treatment of Her2+ breast cancer but its cardiotoxic side effects require regular monitoring by echocardiography. A 10% reduction in left ventricular ejection fraction can lead to suspension of treatment and therefore has significan...

Full description

Bibliographic Details
Main Authors: A King, J Thambyrajah, E Leng, M J Stewart
Format: Article
Language:English
Published: BMC 2016-10-01
Series:Echo Research and Practice
Subjects:
Online Access:http://www.echorespract.com/content/3/3/85.full
_version_ 1818008359140327424
author A King
J Thambyrajah
E Leng
M J Stewart
author_facet A King
J Thambyrajah
E Leng
M J Stewart
author_sort A King
collection DOAJ
description Herceptin (Trastuzumab) is a widely used and effective drug for the treatment of Her2+ breast cancer but its cardiotoxic side effects require regular monitoring by echocardiography. A 10% reduction in left ventricular ejection fraction can lead to suspension of treatment and therefore has significant implications for patient prognosis in terms of cardiac and cancer outcomes. Assessment of LV function by conventional 2D biplane method of discs (2DEF) has limitations in accuracy and reproducibility. Global longitudinal strain (GLS) is becoming more widely available and user friendly. It has been shown to demonstrate myocardial damage earlier in treatment than 2DEF, allowing the option of pharmacological intervention at a pre-clinical stage and preventing the interruption of Herceptin. This study compares the reproducibility of GLS with that of 2DEF in a routine clinical environment. Fifty echocardiograms performed on female patients undergoing Herceptin treatment were used to measure both 2DEF and GLS within the recommended standard appointment time of 40 min. The data were re-measured (blind) by the same operator a minimum of 14 days later to determine intra-operator variation. These data were also measured by a second operator (blind), to assess inter-operator variation. Analysis by direct comparison, intra-class correlation (ICC), coefficient of variation (CV) and Bland–Altman plots demonstrated that GLS is a more reproducible measurement than 2DEF. This is important to prevent clinical decisions being erroneously based on variation in operator measurement. The investigation also shows that with advances in machine software this is a practical addition to routine assessment rather than merely a research tool.
first_indexed 2024-04-14T05:29:09Z
format Article
id doaj.art-686ddfab50194eb79e6346ceb2083c80
institution Directory Open Access Journal
issn 2055-0464
2055-0464
language English
last_indexed 2024-04-14T05:29:09Z
publishDate 2016-10-01
publisher BMC
record_format Article
series Echo Research and Practice
spelling doaj.art-686ddfab50194eb79e6346ceb2083c802022-12-22T02:09:53ZengBMCEcho Research and Practice2055-04642055-04642016-10-0133859310.1530/ERP-16-0022Global longitudinal strain: a useful everyday measurement?A King0J Thambyrajah1E Leng2M J Stewart3Cardiothoracic Division, James Cook University Hospital, Middlesbrough, UKCardiothoracic Division, James Cook University Hospital, Middlesbrough, UKCardiothoracic Division, James Cook University Hospital, Middlesbrough, UKCardiothoracic Division, James Cook University Hospital, Middlesbrough, UKHerceptin (Trastuzumab) is a widely used and effective drug for the treatment of Her2+ breast cancer but its cardiotoxic side effects require regular monitoring by echocardiography. A 10% reduction in left ventricular ejection fraction can lead to suspension of treatment and therefore has significant implications for patient prognosis in terms of cardiac and cancer outcomes. Assessment of LV function by conventional 2D biplane method of discs (2DEF) has limitations in accuracy and reproducibility. Global longitudinal strain (GLS) is becoming more widely available and user friendly. It has been shown to demonstrate myocardial damage earlier in treatment than 2DEF, allowing the option of pharmacological intervention at a pre-clinical stage and preventing the interruption of Herceptin. This study compares the reproducibility of GLS with that of 2DEF in a routine clinical environment. Fifty echocardiograms performed on female patients undergoing Herceptin treatment were used to measure both 2DEF and GLS within the recommended standard appointment time of 40 min. The data were re-measured (blind) by the same operator a minimum of 14 days later to determine intra-operator variation. These data were also measured by a second operator (blind), to assess inter-operator variation. Analysis by direct comparison, intra-class correlation (ICC), coefficient of variation (CV) and Bland–Altman plots demonstrated that GLS is a more reproducible measurement than 2DEF. This is important to prevent clinical decisions being erroneously based on variation in operator measurement. The investigation also shows that with advances in machine software this is a practical addition to routine assessment rather than merely a research tool.http://www.echorespract.com/content/3/3/85.fullreproducibilityejection fractionglobal longitudinal strainherceptin
spellingShingle A King
J Thambyrajah
E Leng
M J Stewart
Global longitudinal strain: a useful everyday measurement?
Echo Research and Practice
reproducibility
ejection fraction
global longitudinal strain
herceptin
title Global longitudinal strain: a useful everyday measurement?
title_full Global longitudinal strain: a useful everyday measurement?
title_fullStr Global longitudinal strain: a useful everyday measurement?
title_full_unstemmed Global longitudinal strain: a useful everyday measurement?
title_short Global longitudinal strain: a useful everyday measurement?
title_sort global longitudinal strain a useful everyday measurement
topic reproducibility
ejection fraction
global longitudinal strain
herceptin
url http://www.echorespract.com/content/3/3/85.full
work_keys_str_mv AT aking globallongitudinalstrainausefuleverydaymeasurement
AT jthambyrajah globallongitudinalstrainausefuleverydaymeasurement
AT eleng globallongitudinalstrainausefuleverydaymeasurement
AT mjstewart globallongitudinalstrainausefuleverydaymeasurement