Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds

In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological...

Full description

Bibliographic Details
Main Authors: Amanda Gomes Lopes, Luiz Tauhata, Luiz Bertelli
Format: Article
Language:English
Published: Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) 2018-09-01
Series:Brazilian Journal of Radiation Sciences
Subjects:
Online Access:https://bjrs.org.br/revista/index.php/REVISTA/article/view/528
_version_ 1798030531256909824
author Amanda Gomes Lopes
Luiz Tauhata
Luiz Bertelli
author_facet Amanda Gomes Lopes
Luiz Tauhata
Luiz Bertelli
author_sort Amanda Gomes Lopes
collection DOAJ
description In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological performance of the equipment, the experimental set up and the scenario of the occurrence of the accident. The methodology to evaluate the performance of the detectors use the comparison of the attenuation coefficient value of each radionuclide obtained by the attenuation curve of tissue-equivalent material to the theoretical value established by NIST in each experimental set up. The good performance was defined when the difference between the experimental and theoretical value is close to zero. The experimental set ups were chosen according to the types of possible measurements performed in the various scenarios of the radiological accident. The detectors used were Personal Radiation Dosimeter, IdentiFINDER2, Cadmium Telluride and Hyper Pure Germanium. The results for 241Am showed better performance with HPGe and IdentiFINDER2 shielded. For the 60Co the best performance occurred with the shielded and collimated IdentiFINDER2. For the 137Cs, the HPGe detector presented the best performance.
first_indexed 2024-04-11T19:42:46Z
format Article
id doaj.art-68a1fd65e5de479c97fd8beb57591705
institution Directory Open Access Journal
issn 2319-0612
language English
last_indexed 2024-04-11T19:42:46Z
publishDate 2018-09-01
publisher Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
record_format Article
series Brazilian Journal of Radiation Sciences
spelling doaj.art-68a1fd65e5de479c97fd8beb575917052022-12-22T04:06:39ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122018-09-016310.15392/bjrs.v6i3.528Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by woundsAmanda Gomes Lopes0Luiz Tauhata1Luiz Bertelli2Instituto de Radioproteção e Dosimetria - IRD/CNENInstituto de Radioproteção e Dosimetria - IRD/CNENLos Alamos National Laboratory (LANL) In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological performance of the equipment, the experimental set up and the scenario of the occurrence of the accident. The methodology to evaluate the performance of the detectors use the comparison of the attenuation coefficient value of each radionuclide obtained by the attenuation curve of tissue-equivalent material to the theoretical value established by NIST in each experimental set up. The good performance was defined when the difference between the experimental and theoretical value is close to zero. The experimental set ups were chosen according to the types of possible measurements performed in the various scenarios of the radiological accident. The detectors used were Personal Radiation Dosimeter, IdentiFINDER2, Cadmium Telluride and Hyper Pure Germanium. The results for 241Am showed better performance with HPGe and IdentiFINDER2 shielded. For the 60Co the best performance occurred with the shielded and collimated IdentiFINDER2. For the 137Cs, the HPGe detector presented the best performance. https://bjrs.org.br/revista/index.php/REVISTA/article/view/528wounds contaminatedincorporation of radionuclidesperformance of detectorsemergency radiological
spellingShingle Amanda Gomes Lopes
Luiz Tauhata
Luiz Bertelli
Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
Brazilian Journal of Radiation Sciences
wounds contaminated
incorporation of radionuclides
performance of detectors
emergency radiological
title Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
title_full Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
title_fullStr Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
title_full_unstemmed Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
title_short Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
title_sort performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
topic wounds contaminated
incorporation of radionuclides
performance of detectors
emergency radiological
url https://bjrs.org.br/revista/index.php/REVISTA/article/view/528
work_keys_str_mv AT amandagomeslopes performanceofdetectorsusedinmeasurementsofradioactivematerialsdepositedintissuesfromintakesbywounds
AT luiztauhata performanceofdetectorsusedinmeasurementsofradioactivematerialsdepositedintissuesfromintakesbywounds
AT luizbertelli performanceofdetectorsusedinmeasurementsofradioactivematerialsdepositedintissuesfromintakesbywounds