Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds
In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
2018-09-01
|
Series: | Brazilian Journal of Radiation Sciences |
Subjects: | |
Online Access: | https://bjrs.org.br/revista/index.php/REVISTA/article/view/528 |
_version_ | 1798030531256909824 |
---|---|
author | Amanda Gomes Lopes Luiz Tauhata Luiz Bertelli |
author_facet | Amanda Gomes Lopes Luiz Tauhata Luiz Bertelli |
author_sort | Amanda Gomes Lopes |
collection | DOAJ |
description |
In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological performance of the equipment, the experimental set up and the scenario of the occurrence of the accident. The methodology to evaluate the performance of the detectors use the comparison of the attenuation coefficient value of each radionuclide obtained by the attenuation curve of tissue-equivalent material to the theoretical value established by NIST in each experimental set up. The good performance was defined when the difference between the experimental and theoretical value is close to zero. The experimental set ups were chosen according to the types of possible measurements performed in the various scenarios of the radiological accident. The detectors used were Personal Radiation Dosimeter, IdentiFINDER2, Cadmium Telluride and Hyper Pure Germanium. The results for 241Am showed better performance with HPGe and IdentiFINDER2 shielded. For the 60Co the best performance occurred with the shielded and collimated IdentiFINDER2. For the 137Cs, the HPGe detector presented the best performance.
|
first_indexed | 2024-04-11T19:42:46Z |
format | Article |
id | doaj.art-68a1fd65e5de479c97fd8beb57591705 |
institution | Directory Open Access Journal |
issn | 2319-0612 |
language | English |
last_indexed | 2024-04-11T19:42:46Z |
publishDate | 2018-09-01 |
publisher | Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) |
record_format | Article |
series | Brazilian Journal of Radiation Sciences |
spelling | doaj.art-68a1fd65e5de479c97fd8beb575917052022-12-22T04:06:39ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122018-09-016310.15392/bjrs.v6i3.528Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by woundsAmanda Gomes Lopes0Luiz Tauhata1Luiz Bertelli2Instituto de Radioproteção e Dosimetria - IRD/CNENInstituto de Radioproteção e Dosimetria - IRD/CNENLos Alamos National Laboratory (LANL) In the care of people injured with wounds with incorporated radioactive material, the basic information is collected, using appropriate detectors, following procedures established in first aid protocol. The reliability of the data collected for medical treatment depends greatly on the metrological performance of the equipment, the experimental set up and the scenario of the occurrence of the accident. The methodology to evaluate the performance of the detectors use the comparison of the attenuation coefficient value of each radionuclide obtained by the attenuation curve of tissue-equivalent material to the theoretical value established by NIST in each experimental set up. The good performance was defined when the difference between the experimental and theoretical value is close to zero. The experimental set ups were chosen according to the types of possible measurements performed in the various scenarios of the radiological accident. The detectors used were Personal Radiation Dosimeter, IdentiFINDER2, Cadmium Telluride and Hyper Pure Germanium. The results for 241Am showed better performance with HPGe and IdentiFINDER2 shielded. For the 60Co the best performance occurred with the shielded and collimated IdentiFINDER2. For the 137Cs, the HPGe detector presented the best performance. https://bjrs.org.br/revista/index.php/REVISTA/article/view/528wounds contaminatedincorporation of radionuclidesperformance of detectorsemergency radiological |
spellingShingle | Amanda Gomes Lopes Luiz Tauhata Luiz Bertelli Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds Brazilian Journal of Radiation Sciences wounds contaminated incorporation of radionuclides performance of detectors emergency radiological |
title | Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds |
title_full | Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds |
title_fullStr | Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds |
title_full_unstemmed | Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds |
title_short | Performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds |
title_sort | performance of detectors used in measurements of radioactive materials deposited in tissues from intakes by wounds |
topic | wounds contaminated incorporation of radionuclides performance of detectors emergency radiological |
url | https://bjrs.org.br/revista/index.php/REVISTA/article/view/528 |
work_keys_str_mv | AT amandagomeslopes performanceofdetectorsusedinmeasurementsofradioactivematerialsdepositedintissuesfromintakesbywounds AT luiztauhata performanceofdetectorsusedinmeasurementsofradioactivematerialsdepositedintissuesfromintakesbywounds AT luizbertelli performanceofdetectorsusedinmeasurementsofradioactivematerialsdepositedintissuesfromintakesbywounds |