Comparing the Efficacy of a Microperforated Titanium Membrane for Guided Bone Regeneration with an Existing Mesh Retainer in Dog Mandibles
Acute-type lateral ridge defects (25 mm × 6 mm × 5 mm) were bilaterally created in the mandibles of four dogs (two defects per animal). The defects were reconstructed with particulate autologous bone and covered with a microperforated titanium membrane (Ti-honeycomb membrane, TiHM) or an existing co...
Main Authors: | Hiroshi Hasegawa, Tetsuharu Kaneko, Manabu Endo, Chihiro Kanno, Morio Yamazaki, Sadanoshin Yaginuma, Hiroki Igarashi, Hideaki Honma, Seiichiro Masui, Mizuki Suto, Yukihiko Sakisaka, Hiroshi Ishihata |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-06-01
|
Series: | Materials |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1944/14/12/3358 |
Similar Items
-
Evaluation of Preosteoblast MC3T3-E1 Cells Cultured on a Microporous Titanium Membrane Fabricated Using a Precise Mechanical Punching Process
by: Jingyu Zhang, et al.
Published: (2020-11-01) -
Serial Cultivation of an MSC-Like Cell Line with Enzyme-Free Passaging Using a Microporous Titanium Scaffold
by: Yukihiko Sakisaka, et al.
Published: (2023-01-01) -
Preparation of Microporous Polypropylene/Titanium Dioxide Composite Membranes with Enhanced Electrolyte Uptake Capability via Melt Extruding and Stretching
by: Shan Wang, et al.
Published: (2017-03-01) -
Advanced microporous membranes for H2/CH4 separation: Challenges and perspectives
by: Rongfei Zhou, et al.
Published: (2021-01-01) -
Multilayered PVDF-HFP Porous Separator via Phase Separation and Selective Solvent Etching for High Voltage Lithium-Ion Batteries
by: Van-Tien Bui, et al.
Published: (2021-01-01)