CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY
Objective: To ascertain the correlation between shoe size and sizes of femoral and tibial components of total knee replacement preoperatively in patients undergoing total knee arthroplasty. Study design: Prospective cohort study Study settings and duration: This study was conducted at departmen...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Rawalpindi Medical University
2023-04-01
|
Series: | Journal of Rawalpindi Medical College |
Subjects: | |
Online Access: | https://journalrmc.com/index.php/JRMC/article/view/1972 |
_version_ | 1797797067941216256 |
---|---|
author | Ahmed Furqan Sohail Hafeez Fahim Khan Ali Asghar Mahin Manzoor Talha Kareem |
author_facet | Ahmed Furqan Sohail Hafeez Fahim Khan Ali Asghar Mahin Manzoor Talha Kareem |
author_sort | Ahmed Furqan |
collection | DOAJ |
description |
Objective: To ascertain the correlation between shoe size and sizes of femoral and tibial components of total knee replacement preoperatively in patients undergoing total knee arthroplasty.
Study design: Prospective cohort study
Study settings and duration: This study was conducted at department of orthopedic surgery, Shifa International Hospital, Islamabad from July 2020 – December 2020.
Material and methods: Sample size was calculated using WHO calculator and it was 43 patients in total. Patients were approached through non-probability consecutive sampling. Shoe size of patients was measured using a Brannock device. During surgery, Implant model and sizes of the femoral and tibial components implanted during knee replacement were noted. Data was analyzed with the help of SPSS version 24. We applied Pearson’s correlation cofficeint. P value ≤ 0.05 was considered significant.
Results: Out of 43, there were 9(20.9%) male and female 34(79.1%). Mean age of patients was 51.7±6.8 (SD). We found good positive correlation between shoe size and tibial component (p=<0.001). Positive co relation was found between femoral component and shoe size (p=0.001). Shoe size predict 72% of Tibial component and 65% femoral component.
Conclusion: Shoe size is effective and safe predictors of total knee replacement components pre-operatively. This procedure is more accurate and less labor intensive. Accurate templating result in less surgical duration and provide several benefits to patients and health care providers.
|
first_indexed | 2024-03-13T03:42:35Z |
format | Article |
id | doaj.art-69177801754549b78e27a19cd5f7170c |
institution | Directory Open Access Journal |
issn | 1683-3562 1683-3570 |
language | English |
last_indexed | 2024-03-13T03:42:35Z |
publishDate | 2023-04-01 |
publisher | Rawalpindi Medical University |
record_format | Article |
series | Journal of Rawalpindi Medical College |
spelling | doaj.art-69177801754549b78e27a19cd5f7170c2023-06-23T06:33:18ZengRawalpindi Medical UniversityJournal of Rawalpindi Medical College1683-35621683-35702023-04-0127110.37939/jrmc.v27i1.1972CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELYAhmed FurqanSohail HafeezFahim KhanAli AsgharMahin ManzoorTalha Kareem Objective: To ascertain the correlation between shoe size and sizes of femoral and tibial components of total knee replacement preoperatively in patients undergoing total knee arthroplasty. Study design: Prospective cohort study Study settings and duration: This study was conducted at department of orthopedic surgery, Shifa International Hospital, Islamabad from July 2020 – December 2020. Material and methods: Sample size was calculated using WHO calculator and it was 43 patients in total. Patients were approached through non-probability consecutive sampling. Shoe size of patients was measured using a Brannock device. During surgery, Implant model and sizes of the femoral and tibial components implanted during knee replacement were noted. Data was analyzed with the help of SPSS version 24. We applied Pearson’s correlation cofficeint. P value ≤ 0.05 was considered significant. Results: Out of 43, there were 9(20.9%) male and female 34(79.1%). Mean age of patients was 51.7±6.8 (SD). We found good positive correlation between shoe size and tibial component (p=<0.001). Positive co relation was found between femoral component and shoe size (p=0.001). Shoe size predict 72% of Tibial component and 65% femoral component. Conclusion: Shoe size is effective and safe predictors of total knee replacement components pre-operatively. This procedure is more accurate and less labor intensive. Accurate templating result in less surgical duration and provide several benefits to patients and health care providers. https://journalrmc.com/index.php/JRMC/article/view/1972Femoral Component, Shoe Size, Tibial Component, Total Knee Replacement |
spellingShingle | Ahmed Furqan Sohail Hafeez Fahim Khan Ali Asghar Mahin Manzoor Talha Kareem CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY Journal of Rawalpindi Medical College Femoral Component, Shoe Size, Tibial Component, Total Knee Replacement |
title | CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY |
title_full | CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY |
title_fullStr | CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY |
title_full_unstemmed | CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY |
title_short | CAN SHOE SIZE CORRECTLY PREDICT THE SIZE OF COMPONENTS OF TOTAL KNEE REPLACEMENT PRE-OPERATIVELY |
title_sort | can shoe size correctly predict the size of components of total knee replacement pre operatively |
topic | Femoral Component, Shoe Size, Tibial Component, Total Knee Replacement |
url | https://journalrmc.com/index.php/JRMC/article/view/1972 |
work_keys_str_mv | AT ahmedfurqan canshoesizecorrectlypredictthesizeofcomponentsoftotalkneereplacementpreoperatively AT sohailhafeez canshoesizecorrectlypredictthesizeofcomponentsoftotalkneereplacementpreoperatively AT fahimkhan canshoesizecorrectlypredictthesizeofcomponentsoftotalkneereplacementpreoperatively AT aliasghar canshoesizecorrectlypredictthesizeofcomponentsoftotalkneereplacementpreoperatively AT mahinmanzoor canshoesizecorrectlypredictthesizeofcomponentsoftotalkneereplacementpreoperatively AT talhakareem canshoesizecorrectlypredictthesizeofcomponentsoftotalkneereplacementpreoperatively |