Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil
Due to high boiling temperature, organic acids are present in the warmer areas of metal equipment from atmospheric and vacuum distillation units and determine, increased corrosion processes in furnace tubes, transfer lines, metal equipment within the distillation columns etc. In order to protect...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Kragujevac
2011-12-01
|
Series: | Tribology in Industry |
Subjects: | |
Online Access: | http://www.tribology.fink.rs/journals/2011/2011-4/1.pdf |
_version_ | 1819071632043409408 |
---|---|
author | M. Morosanu M. G. Petrescu N. N. Antonescu |
author_facet | M. Morosanu M. G. Petrescu N. N. Antonescu |
author_sort | M. Morosanu |
collection | DOAJ |
description | Due to high boiling temperature, organic acids are present in the warmer areas of metal equipment from atmospheric and vacuum distillation units and determine, increased corrosion processes in furnace tubes, transfer lines, metal equipment within the distillation columns etc. In order to protect the corrosion of metal equipment from atmospheric and vacuum distillation units, against acids, de authors researched solution which integrates corrosion inhibitors and selecting materials for equipment construction. For this purpose, we tested the inhibitor PET 1441, which has dialchilfosfat in his composition and inhibitor based on phosphate ester. In this case, to the metal surface forms a complex phosphorous that forms of high temperature and high fluid speed. In order to form the passive layer and to achieve a 90% protection, we initially insert a shock dose, and in order to ensure further protection there is used a dose of 20 ppm. The check of anticorrosion protection namely the inhibition efficiency is achieved by testing samples made from steel different. |
first_indexed | 2024-12-21T17:24:55Z |
format | Article |
id | doaj.art-6982d520d881418eaf2ac02988644afe |
institution | Directory Open Access Journal |
issn | 0354-8996 2217-7965 |
language | English |
last_indexed | 2024-12-21T17:24:55Z |
publishDate | 2011-12-01 |
publisher | University of Kragujevac |
record_format | Article |
series | Tribology in Industry |
spelling | doaj.art-6982d520d881418eaf2ac02988644afe2022-12-21T18:56:04ZengUniversity of KragujevacTribology in Industry0354-89962217-79652011-12-01334140145Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude OilM. Morosanu 0M. G. Petrescu1N. N. Antonescu2Petroleum-Gas University from Ploiesti, RomaniaPetroleum-Gas University from Ploiesti, RomaniaPetroleum-Gas University from Ploiesti, RomaniaDue to high boiling temperature, organic acids are present in the warmer areas of metal equipment from atmospheric and vacuum distillation units and determine, increased corrosion processes in furnace tubes, transfer lines, metal equipment within the distillation columns etc. In order to protect the corrosion of metal equipment from atmospheric and vacuum distillation units, against acids, de authors researched solution which integrates corrosion inhibitors and selecting materials for equipment construction. For this purpose, we tested the inhibitor PET 1441, which has dialchilfosfat in his composition and inhibitor based on phosphate ester. In this case, to the metal surface forms a complex phosphorous that forms of high temperature and high fluid speed. In order to form the passive layer and to achieve a 90% protection, we initially insert a shock dose, and in order to ensure further protection there is used a dose of 20 ppm. The check of anticorrosion protection namely the inhibition efficiency is achieved by testing samples made from steel different.http://www.tribology.fink.rs/journals/2011/2011-4/1.pdfcorrosionatmospheric and vacuum distillation unitsanticorrosive protectiondistillation columcorrosion inhibitor.corrosion inhibitor |
spellingShingle | M. Morosanu M. G. Petrescu N. N. Antonescu Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil Tribology in Industry corrosion atmospheric and vacuum distillation units anticorrosive protection distillation colum corrosion inhibitor. corrosion inhibitor |
title | Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil |
title_full | Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil |
title_fullStr | Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil |
title_full_unstemmed | Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil |
title_short | Research Regarding the Anticorosiv Protection of Atmospheric and Vacuum Distillation Unit that Process Crude Oil |
title_sort | research regarding the anticorosiv protection of atmospheric and vacuum distillation unit that process crude oil |
topic | corrosion atmospheric and vacuum distillation units anticorrosive protection distillation colum corrosion inhibitor. corrosion inhibitor |
url | http://www.tribology.fink.rs/journals/2011/2011-4/1.pdf |
work_keys_str_mv | AT mmorosanu researchregardingtheanticorosivprotectionofatmosphericandvacuumdistillationunitthatprocesscrudeoil AT mgpetrescu researchregardingtheanticorosivprotectionofatmosphericandvacuumdistillationunitthatprocesscrudeoil AT nnantonescu researchregardingtheanticorosivprotectionofatmosphericandvacuumdistillationunitthatprocesscrudeoil |