Closed-loop control of k-space sampling via physiologic feedback for cine MRI.

<h4>Background</h4>Segmented cine cardiac MRI combines data from multiple heartbeats to achieve high spatiotemporal resolution cardiac images, yet predefined k-space segmentation trajectories can lead to suboptimal k-space sampling. In this work, we developed and evaluated an autonomous...

Full description

Bibliographic Details
Main Authors: Francisco Contijoch, Yuchi Han, Srikant Kamesh Iyer, Peter Kellman, Gene Gualtieri, Mark A Elliott, Sebastian Berisha, Joseph H Gorman, Robert C Gorman, James J Pilla, Walter R T Witschey
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0244286
_version_ 1811339488750731264
author Francisco Contijoch
Yuchi Han
Srikant Kamesh Iyer
Peter Kellman
Gene Gualtieri
Mark A Elliott
Sebastian Berisha
Joseph H Gorman
Robert C Gorman
James J Pilla
Walter R T Witschey
author_facet Francisco Contijoch
Yuchi Han
Srikant Kamesh Iyer
Peter Kellman
Gene Gualtieri
Mark A Elliott
Sebastian Berisha
Joseph H Gorman
Robert C Gorman
James J Pilla
Walter R T Witschey
author_sort Francisco Contijoch
collection DOAJ
description <h4>Background</h4>Segmented cine cardiac MRI combines data from multiple heartbeats to achieve high spatiotemporal resolution cardiac images, yet predefined k-space segmentation trajectories can lead to suboptimal k-space sampling. In this work, we developed and evaluated an autonomous and closed-loop control system for radial k-space sampling (ARKS) to increase sampling uniformity.<h4>Methods</h4>The closed-loop system autonomously selects radial k-space sampling trajectory during live segmented cine MRI and attempts to optimize angular sampling uniformity by selecting views in regions of k-space that were not previously well-sampled. Sampling uniformity and the ability to detect cardiac phase in vivo was assessed using ECG data acquired from 10 normal subjects in an MRI scanner. The approach was then implemented with a fast gradient echo sequence on a whole-body clinical MRI scanner and imaging was performed in 4 healthy volunteers. The closed-loop k-space trajectory was compared to random, uniformly distributed and golden angle view trajectories via measurement of k-space uniformity and the point spread function. Lastly, an arrhythmic dataset was used to evaluate a potential application of the approach.<h4>Results</h4>The autonomous trajectory increased k-space sampling uniformity by 15±7%, main lobe point spread function (PSF) signal intensity by 6±4%, and reduced ringing relative to golden angle sampling. When implemented, the autonomous pulse sequence prescribed radial view angles faster than the scan TR (0.98 ± 0.01 ms, maximum = 1.38 ms) and increased k-space sampling mean uniformity by 10±11%, decreased uniformity variability by 44±12%, and increased PSF signal ratio by 6±6% relative to golden angle sampling.<h4>Conclusion</h4>The closed-loop approach enables near-uniform radial sampling in a segmented acquisition approach which was higher than predetermined golden-angle radial sampling. This can be utilized to increase the sampling or decrease the temporal footprint of an acquisition and the closed-loop framework has the potential to be applied to patients with complex heart rhythms.
first_indexed 2024-04-13T18:27:25Z
format Article
id doaj.art-699389d87a414ce89f13e6a4d774aa11
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-13T18:27:25Z
publishDate 2020-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-699389d87a414ce89f13e6a4d774aa112022-12-22T02:35:12ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-011512e024428610.1371/journal.pone.0244286Closed-loop control of k-space sampling via physiologic feedback for cine MRI.Francisco ContijochYuchi HanSrikant Kamesh IyerPeter KellmanGene GualtieriMark A ElliottSebastian BerishaJoseph H GormanRobert C GormanJames J PillaWalter R T Witschey<h4>Background</h4>Segmented cine cardiac MRI combines data from multiple heartbeats to achieve high spatiotemporal resolution cardiac images, yet predefined k-space segmentation trajectories can lead to suboptimal k-space sampling. In this work, we developed and evaluated an autonomous and closed-loop control system for radial k-space sampling (ARKS) to increase sampling uniformity.<h4>Methods</h4>The closed-loop system autonomously selects radial k-space sampling trajectory during live segmented cine MRI and attempts to optimize angular sampling uniformity by selecting views in regions of k-space that were not previously well-sampled. Sampling uniformity and the ability to detect cardiac phase in vivo was assessed using ECG data acquired from 10 normal subjects in an MRI scanner. The approach was then implemented with a fast gradient echo sequence on a whole-body clinical MRI scanner and imaging was performed in 4 healthy volunteers. The closed-loop k-space trajectory was compared to random, uniformly distributed and golden angle view trajectories via measurement of k-space uniformity and the point spread function. Lastly, an arrhythmic dataset was used to evaluate a potential application of the approach.<h4>Results</h4>The autonomous trajectory increased k-space sampling uniformity by 15±7%, main lobe point spread function (PSF) signal intensity by 6±4%, and reduced ringing relative to golden angle sampling. When implemented, the autonomous pulse sequence prescribed radial view angles faster than the scan TR (0.98 ± 0.01 ms, maximum = 1.38 ms) and increased k-space sampling mean uniformity by 10±11%, decreased uniformity variability by 44±12%, and increased PSF signal ratio by 6±6% relative to golden angle sampling.<h4>Conclusion</h4>The closed-loop approach enables near-uniform radial sampling in a segmented acquisition approach which was higher than predetermined golden-angle radial sampling. This can be utilized to increase the sampling or decrease the temporal footprint of an acquisition and the closed-loop framework has the potential to be applied to patients with complex heart rhythms.https://doi.org/10.1371/journal.pone.0244286
spellingShingle Francisco Contijoch
Yuchi Han
Srikant Kamesh Iyer
Peter Kellman
Gene Gualtieri
Mark A Elliott
Sebastian Berisha
Joseph H Gorman
Robert C Gorman
James J Pilla
Walter R T Witschey
Closed-loop control of k-space sampling via physiologic feedback for cine MRI.
PLoS ONE
title Closed-loop control of k-space sampling via physiologic feedback for cine MRI.
title_full Closed-loop control of k-space sampling via physiologic feedback for cine MRI.
title_fullStr Closed-loop control of k-space sampling via physiologic feedback for cine MRI.
title_full_unstemmed Closed-loop control of k-space sampling via physiologic feedback for cine MRI.
title_short Closed-loop control of k-space sampling via physiologic feedback for cine MRI.
title_sort closed loop control of k space sampling via physiologic feedback for cine mri
url https://doi.org/10.1371/journal.pone.0244286
work_keys_str_mv AT franciscocontijoch closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT yuchihan closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT srikantkameshiyer closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT peterkellman closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT genegualtieri closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT markaelliott closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT sebastianberisha closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT josephhgorman closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT robertcgorman closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT jamesjpilla closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri
AT walterrtwitschey closedloopcontrolofkspacesamplingviaphysiologicfeedbackforcinemri