A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering
In terms of dose distribution, protons are more sensitive to range variations than photons due to their unique properties. The aim of this study was to develop a method to identify patient-specific robust proton beam angles for lung tumor irradiation by investigating the association between water eq...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2020-08-01
|
Series: | Technology in Cancer Research & Treatment |
Online Access: | https://doi.org/10.1177/1533033820948052 |
_version_ | 1818441860552589312 |
---|---|
author | Yawei Zhang PhD Meng Wei Ho MS Zuofeng Li DSc |
author_facet | Yawei Zhang PhD Meng Wei Ho MS Zuofeng Li DSc |
author_sort | Yawei Zhang PhD |
collection | DOAJ |
description | In terms of dose distribution, protons are more sensitive to range variations than photons due to their unique properties. The aim of this study was to develop a method to identify patient-specific robust proton beam angles for lung tumor irradiation by investigating the association between water equivalent thickness (WET) variation and inter-fraction motion-induced target dose degradation. Using 3-dimensional computed tomography (3D-CT) images, the impact of WET variations on the target dose coverage of a series of coplanar proton beams was evaluated for 4 patients with lung cancer. Using ray tracing, WET maps, or WET baseline, were estimated for the internal target volume (ITV) at every 5° gantry interval in the axial plane. After calculating the WET baseline, the planning CT was shifted 5 mm in each anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction, yielding a total of 6 shifted CTs, and differential WET maps between the planning CT and each shifted CT were calculated. Target dose differences were associated with the average WET change between the original planning CT and the shifted CTs for all 360° gantry rotation beams. Target and OAR dose metrics in the ΔWET-guided plans were compared with those of the clinical plans. The WET variation maps showed areas of both high and low WET variations, with overall similar patterns yet individual differences reflecting tumor position differences. For all 4 patients investigated in this study, the coplanar plans demonstrated a strong correlation between WET changes and ITV dose reductions. Target dose coverage was more stable with the ΔWET-guided plan while OAR doses were comparable to the clinical plan. The WET variation maps have been used in this pilot study to identify proton beam angles that are either sensitive or robust to WET changes in proton passive scattering. This work demonstrates the feasibility of using WET variation maps to assist the planner in inter-fraction motion-robust proton beam angle selection. |
first_indexed | 2024-12-14T18:34:58Z |
format | Article |
id | doaj.art-69a6145ad74d4ee0b389aaf2280d0da3 |
institution | Directory Open Access Journal |
issn | 1533-0338 |
language | English |
last_indexed | 2024-12-14T18:34:58Z |
publishDate | 2020-08-01 |
publisher | SAGE Publishing |
record_format | Article |
series | Technology in Cancer Research & Treatment |
spelling | doaj.art-69a6145ad74d4ee0b389aaf2280d0da32022-12-21T22:51:39ZengSAGE PublishingTechnology in Cancer Research & Treatment1533-03382020-08-011910.1177/1533033820948052A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton ScatteringYawei Zhang PhD0Meng Wei Ho MS1Zuofeng Li DSc2 Department of Radiation Oncology, University of Florida, Gainesville, FL, USA Department of Radiation Oncology, University of Florida, Gainesville, FL, USA Department of Radiation Oncology, University of Florida, Gainesville, FL, USAIn terms of dose distribution, protons are more sensitive to range variations than photons due to their unique properties. The aim of this study was to develop a method to identify patient-specific robust proton beam angles for lung tumor irradiation by investigating the association between water equivalent thickness (WET) variation and inter-fraction motion-induced target dose degradation. Using 3-dimensional computed tomography (3D-CT) images, the impact of WET variations on the target dose coverage of a series of coplanar proton beams was evaluated for 4 patients with lung cancer. Using ray tracing, WET maps, or WET baseline, were estimated for the internal target volume (ITV) at every 5° gantry interval in the axial plane. After calculating the WET baseline, the planning CT was shifted 5 mm in each anterior-posterior (AP), superior-inferior (SI), and left-right (LR) direction, yielding a total of 6 shifted CTs, and differential WET maps between the planning CT and each shifted CT were calculated. Target dose differences were associated with the average WET change between the original planning CT and the shifted CTs for all 360° gantry rotation beams. Target and OAR dose metrics in the ΔWET-guided plans were compared with those of the clinical plans. The WET variation maps showed areas of both high and low WET variations, with overall similar patterns yet individual differences reflecting tumor position differences. For all 4 patients investigated in this study, the coplanar plans demonstrated a strong correlation between WET changes and ITV dose reductions. Target dose coverage was more stable with the ΔWET-guided plan while OAR doses were comparable to the clinical plan. The WET variation maps have been used in this pilot study to identify proton beam angles that are either sensitive or robust to WET changes in proton passive scattering. This work demonstrates the feasibility of using WET variation maps to assist the planner in inter-fraction motion-robust proton beam angle selection.https://doi.org/10.1177/1533033820948052 |
spellingShingle | Yawei Zhang PhD Meng Wei Ho MS Zuofeng Li DSc A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering Technology in Cancer Research & Treatment |
title | A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering |
title_full | A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering |
title_fullStr | A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering |
title_full_unstemmed | A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering |
title_short | A Beam-Angle-Selection Method to Improve Inter-Fraction Motion Robustness for Lung Tumor Irradiation With Passive Proton Scattering |
title_sort | beam angle selection method to improve inter fraction motion robustness for lung tumor irradiation with passive proton scattering |
url | https://doi.org/10.1177/1533033820948052 |
work_keys_str_mv | AT yaweizhangphd abeamangleselectionmethodtoimproveinterfractionmotionrobustnessforlungtumorirradiationwithpassiveprotonscattering AT mengweihoms abeamangleselectionmethodtoimproveinterfractionmotionrobustnessforlungtumorirradiationwithpassiveprotonscattering AT zuofenglidsc abeamangleselectionmethodtoimproveinterfractionmotionrobustnessforlungtumorirradiationwithpassiveprotonscattering AT yaweizhangphd beamangleselectionmethodtoimproveinterfractionmotionrobustnessforlungtumorirradiationwithpassiveprotonscattering AT mengweihoms beamangleselectionmethodtoimproveinterfractionmotionrobustnessforlungtumorirradiationwithpassiveprotonscattering AT zuofenglidsc beamangleselectionmethodtoimproveinterfractionmotionrobustnessforlungtumorirradiationwithpassiveprotonscattering |