Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements

Purpose: The purpose of the study was to estimate the backscatter electron dose in internal shielding during electron beam therapy using Monte Carlo (MC) simulations and Gafchromic film measurements. Materials and Methods: About 6 and 9 MeV electron beams from a Varian 2100C linac were simulated usi...

Full description

Bibliographic Details
Main Authors: Sukhvir Singh, Manoj Kumar Semwal, C P Bhatt
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2019-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2019;volume=44;issue=4;spage=239;epage=245;aulast=Singh
_version_ 1818300460888489984
author Sukhvir Singh
Manoj Kumar Semwal
C P Bhatt
author_facet Sukhvir Singh
Manoj Kumar Semwal
C P Bhatt
author_sort Sukhvir Singh
collection DOAJ
description Purpose: The purpose of the study was to estimate the backscatter electron dose in internal shielding during electron beam therapy using Monte Carlo (MC) simulations and Gafchromic film measurements. Materials and Methods: About 6 and 9 MeV electron beams from a Varian 2100C linac were simulated using BEAMnrc MC code. Various clinical situations of internal shielding were simulated by modeling water phantoms with 2 mm lead sheets placed at different depths. Electron backscatter factors (EBF), a ratio of dose at tissue-shielding interface to the dose at the same point without the shielding, were estimated. The role of 2 mm aluminum in reduction of backscatter was investigated. The measurements were also performed using Gafchromic films and results were compared with MC simulations. Results: For particular beam energy, the EBF value initially increased with depth in the buildup region and then decreased rapidly. The highest value of EBF for both the energies is nearly same though at different depths. Decreased EBF was observed for 9 MeV beam in comparison to the 6 MeV beam for the same depth of shielding placement. Two millimeter aluminum reduced the backscatter by nearly 25% at maximum backscatter condition for both the energies, though the effectiveness slightly decreased at higher energy. The range of backscatter electrons was varying from 5 to 12 mm in the upstream direction from the interface. The Gafchromic film-measured EBF and MC-simulated EBF were matching well within the clinically acceptable limits except in close vicinity of tissue-lead interface. Conclusions: This study provides an important clinical data to design internal shielding at the local clinical setup and confirms applicability of MC simulations in backscatter dose calculations at interfaces where physical measurements are difficult to perform.
first_indexed 2024-12-13T05:07:29Z
format Article
id doaj.art-69e88cf7870746b7a4c9ab3462817781
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-12-13T05:07:29Z
publishDate 2019-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-69e88cf7870746b7a4c9ab34628177812022-12-21T23:58:37ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132019-01-0144423924510.4103/jmp.JMP_21_19Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurementsSukhvir SinghManoj Kumar SemwalC P BhattPurpose: The purpose of the study was to estimate the backscatter electron dose in internal shielding during electron beam therapy using Monte Carlo (MC) simulations and Gafchromic film measurements. Materials and Methods: About 6 and 9 MeV electron beams from a Varian 2100C linac were simulated using BEAMnrc MC code. Various clinical situations of internal shielding were simulated by modeling water phantoms with 2 mm lead sheets placed at different depths. Electron backscatter factors (EBF), a ratio of dose at tissue-shielding interface to the dose at the same point without the shielding, were estimated. The role of 2 mm aluminum in reduction of backscatter was investigated. The measurements were also performed using Gafchromic films and results were compared with MC simulations. Results: For particular beam energy, the EBF value initially increased with depth in the buildup region and then decreased rapidly. The highest value of EBF for both the energies is nearly same though at different depths. Decreased EBF was observed for 9 MeV beam in comparison to the 6 MeV beam for the same depth of shielding placement. Two millimeter aluminum reduced the backscatter by nearly 25% at maximum backscatter condition for both the energies, though the effectiveness slightly decreased at higher energy. The range of backscatter electrons was varying from 5 to 12 mm in the upstream direction from the interface. The Gafchromic film-measured EBF and MC-simulated EBF were matching well within the clinically acceptable limits except in close vicinity of tissue-lead interface. Conclusions: This study provides an important clinical data to design internal shielding at the local clinical setup and confirms applicability of MC simulations in backscatter dose calculations at interfaces where physical measurements are difficult to perform.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2019;volume=44;issue=4;spage=239;epage=245;aulast=Singhelectron backscatterelectron radiotherapyinternal shieldingmonte carlo simulation
spellingShingle Sukhvir Singh
Manoj Kumar Semwal
C P Bhatt
Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements
Journal of Medical Physics
electron backscatter
electron radiotherapy
internal shielding
monte carlo simulation
title Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements
title_full Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements
title_fullStr Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements
title_full_unstemmed Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements
title_short Estimation of backscatter from internal shielding in electron beam radiotherapy using Monte Carlo simulations (EGSnrc) and Gafchromic film measurements
title_sort estimation of backscatter from internal shielding in electron beam radiotherapy using monte carlo simulations egsnrc and gafchromic film measurements
topic electron backscatter
electron radiotherapy
internal shielding
monte carlo simulation
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2019;volume=44;issue=4;spage=239;epage=245;aulast=Singh
work_keys_str_mv AT sukhvirsingh estimationofbackscatterfrominternalshieldinginelectronbeamradiotherapyusingmontecarlosimulationsegsnrcandgafchromicfilmmeasurements
AT manojkumarsemwal estimationofbackscatterfrominternalshieldinginelectronbeamradiotherapyusingmontecarlosimulationsegsnrcandgafchromicfilmmeasurements
AT cpbhatt estimationofbackscatterfrominternalshieldinginelectronbeamradiotherapyusingmontecarlosimulationsegsnrcandgafchromicfilmmeasurements