Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose
This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadz...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
2016-10-01
|
Series: | Радиационная гигиена |
Subjects: | |
Online Access: | https://www.radhyg.ru/jour/article/view/380 |
_version_ | 1826546734882357248 |
---|---|
author | I. P. Stamat V. A. Venkov O. E. Tutelyan S. I. Kuvshinnikov G. A. Gorskiy |
author_facet | I. P. Stamat V. A. Venkov O. E. Tutelyan S. I. Kuvshinnikov G. A. Gorskiy |
author_sort | I. P. Stamat |
collection | DOAJ |
description | This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc.) which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment. |
first_indexed | 2024-04-10T01:22:54Z |
format | Article |
id | doaj.art-6a43529aebf44254bd5fa101990715f4 |
institution | Directory Open Access Journal |
issn | 1998-426X |
language | English |
last_indexed | 2025-03-14T05:38:28Z |
publishDate | 2016-10-01 |
publisher | Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev |
record_format | Article |
series | Радиационная гигиена |
spelling | doaj.art-6a43529aebf44254bd5fa101990715f42025-03-05T14:03:15ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2016-10-0193536010.21514/1998-426X-2016-9-3-53-60371Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation doseI. P. Stamat0V. A. Venkov1O. E. Tutelyan2S. I. Kuvshinnikov3G. A. Gorskiy4Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-Being, Saint-Petersburg, RussiaSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-Being, Saint-Petersburg, RussiaFederal Center of Hygiene and Epidemiology, Federal Service for Surveillance on Consumer rights Protection and Human Well-Being, Moscow, RussiaFederal Center of Hygiene and Epidemiology, Federal Service for Surveillance on Consumer rights Protection and Human Well-Being, Moscow, RussiaNorth-Western State Medical University named after I.I. Mechnicov, of the Ministry of Health Care of the Russian Federation, Saint-Petersburg, RussiaThis paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc.) which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.https://www.radhyg.ru/jour/article/view/380gamma radiation (photon radiation) dosimeterpopulation external irradiation dosesdosimeter own background leveldosimeter space radiation responsescintillation detectorgas-discharge detectorgeiger-mueller counter |
spellingShingle | I. P. Stamat V. A. Venkov O. E. Tutelyan S. I. Kuvshinnikov G. A. Gorskiy Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose Радиационная гигиена gamma radiation (photon radiation) dosimeter population external irradiation doses dosimeter own background level dosimeter space radiation response scintillation detector gas-discharge detector geiger-mueller counter |
title | Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose |
title_full | Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose |
title_fullStr | Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose |
title_full_unstemmed | Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose |
title_short | Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose |
title_sort | assessment of population external irradiation doses with consideration of rospotrebnadzor bodies equipment for monitoring of photon radiation dose |
topic | gamma radiation (photon radiation) dosimeter population external irradiation doses dosimeter own background level dosimeter space radiation response scintillation detector gas-discharge detector geiger-mueller counter |
url | https://www.radhyg.ru/jour/article/view/380 |
work_keys_str_mv | AT ipstamat assessmentofpopulationexternalirradiationdoseswithconsiderationofrospotrebnadzorbodiesequipmentformonitoringofphotonradiationdose AT vavenkov assessmentofpopulationexternalirradiationdoseswithconsiderationofrospotrebnadzorbodiesequipmentformonitoringofphotonradiationdose AT oetutelyan assessmentofpopulationexternalirradiationdoseswithconsiderationofrospotrebnadzorbodiesequipmentformonitoringofphotonradiationdose AT sikuvshinnikov assessmentofpopulationexternalirradiationdoseswithconsiderationofrospotrebnadzorbodiesequipmentformonitoringofphotonradiationdose AT gagorskiy assessmentofpopulationexternalirradiationdoseswithconsiderationofrospotrebnadzorbodiesequipmentformonitoringofphotonradiationdose |