Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period
<i>Background and Objectives:</i> To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. <i>Materials and Method:</i> T...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-10-01
|
Series: | Medicina |
Subjects: | |
Online Access: | https://www.mdpi.com/1648-9144/58/11/1570 |
_version_ | 1827646143006244864 |
---|---|
author | Ho-Kyung Lim Sung-Jae Lee Yujin Jeong Jong-Seok Lee Jae-Jun Ryu Ji-Suk Shim In-Seok Song |
author_facet | Ho-Kyung Lim Sung-Jae Lee Yujin Jeong Jong-Seok Lee Jae-Jun Ryu Ji-Suk Shim In-Seok Song |
author_sort | Ho-Kyung Lim |
collection | DOAJ |
description | <i>Background and Objectives:</i> To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. <i>Materials and Method:</i> The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions. In addition, measurements were performed on the day of surgery, two weeks, one month, two months, and three months after surgery for a total of five times. After the standardization of the measured values, the differences and changes over time for each device were observed. <i>Result:</i> No difference in standardized values between the two devices was observed at any time point. In both devices, stability decreased at two weeks postoperatively but gradually increased thereafter. No differences were observed in the values according to the measurement direction. <i>Conclusions:</i> The damping capacity of Anycheck was similar to that of Periotest M. After a slight decrease in stability two weeks after implant placement, implant stability increased over time. |
first_indexed | 2024-03-09T18:51:53Z |
format | Article |
id | doaj.art-6a5a397b489a4978af17d92245c2082e |
institution | Directory Open Access Journal |
issn | 1010-660X 1648-9144 |
language | English |
last_indexed | 2024-03-09T18:51:53Z |
publishDate | 2022-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Medicina |
spelling | doaj.art-6a5a397b489a4978af17d92245c2082e2023-11-24T05:46:57ZengMDPI AGMedicina1010-660X1648-91442022-10-015811157010.3390/medicina58111570Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing PeriodHo-Kyung Lim0Sung-Jae Lee1Yujin Jeong2Jong-Seok Lee3Jae-Jun Ryu4Ji-Suk Shim5In-Seok Song6Department of Oral & Maxillofacial Surgery, Korea University Guro Hospital, Seoul 08308, KoreaDepartment of Oral & Maxillofacial Surgery, Korea University Anam Hospital, Seoul 02841, KoreaDepartment of Biostatistics, Korea University College of Medicine, Seoul 02841, KoreaDepartment of Prosthodontics, Korea University Anam Hospital, Seoul 02841, KoreaDepartment of Prosthodontics, Korea University Anam Hospital, Seoul 02841, KoreaDepartment of Prosthodontics, Korea University Guro Hospital, Seoul 08308, KoreaDepartment of Oral & Maxillofacial Surgery, Korea University Anam Hospital, Seoul 02841, Korea<i>Background and Objectives:</i> To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. <i>Materials and Method:</i> The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions. In addition, measurements were performed on the day of surgery, two weeks, one month, two months, and three months after surgery for a total of five times. After the standardization of the measured values, the differences and changes over time for each device were observed. <i>Result:</i> No difference in standardized values between the two devices was observed at any time point. In both devices, stability decreased at two weeks postoperatively but gradually increased thereafter. No differences were observed in the values according to the measurement direction. <i>Conclusions:</i> The damping capacity of Anycheck was similar to that of Periotest M. After a slight decrease in stability two weeks after implant placement, implant stability increased over time.https://www.mdpi.com/1648-9144/58/11/1570dental implantsstabilitydentistryanalytic device |
spellingShingle | Ho-Kyung Lim Sung-Jae Lee Yujin Jeong Jong-Seok Lee Jae-Jun Ryu Ji-Suk Shim In-Seok Song Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period Medicina dental implants stability dentistry analytic device |
title | Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period |
title_full | Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period |
title_fullStr | Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period |
title_full_unstemmed | Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period |
title_short | Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period |
title_sort | clinical validation of dental implant stability by newly designed damping capacity assessment device during the healing period |
topic | dental implants stability dentistry analytic device |
url | https://www.mdpi.com/1648-9144/58/11/1570 |
work_keys_str_mv | AT hokyunglim clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod AT sungjaelee clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod AT yujinjeong clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod AT jongseoklee clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod AT jaejunryu clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod AT jisukshim clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod AT inseoksong clinicalvalidationofdentalimplantstabilitybynewlydesigneddampingcapacityassessmentdeviceduringthehealingperiod |