Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.

Precision cut liver slices represent an encouraging ex vivo method to understand the pathogenesis of liver disease alongside drug induced liver injury. Despite being more physiologically relevant compared to in vitro models, precision cut liver slices are limited by the availability of healthy human...

Full description

Bibliographic Details
Main Authors: S J Chidlow, L E Randle, R A Kelly
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2022-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0275788
_version_ 1797861016260837376
author S J Chidlow
L E Randle
R A Kelly
author_facet S J Chidlow
L E Randle
R A Kelly
author_sort S J Chidlow
collection DOAJ
description Precision cut liver slices represent an encouraging ex vivo method to understand the pathogenesis of liver disease alongside drug induced liver injury. Despite being more physiologically relevant compared to in vitro models, precision cut liver slices are limited by the availability of healthy human tissue and experimental variability. Internal oxygen concentration and media composition govern the longevity and viability of the slices during the culture period and as such, a variety of approaches have been taken to maximise the appropriateness of the internal oxygen concentrations across the slice. The aim of this study was to predict whether it is possible to generate a physiologically relevant oxygen gradient of 35-65mmHg across a precision cut liver slice using mathematical modelling. Simulations explore how the internal oxygen concentration changes as a function of the diameter of the slice, the position inside the well and the external incubator oxygen concentration. The model predicts that the desired oxygen gradient may be achieved using a 5mm diameter slice at atmospheric oxygen concentrations, provided that the slice is positioned at a certain height within the well of a 12-well plate.
first_indexed 2024-04-09T21:55:14Z
format Article
id doaj.art-6a64cdb531b54d569ef6025762b8d4ef
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-09T21:55:14Z
publishDate 2022-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-6a64cdb531b54d569ef6025762b8d4ef2023-03-24T05:32:14ZengPublic Library of Science (PLoS)PLoS ONE1932-62032022-01-011711e027578810.1371/journal.pone.0275788Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.S J ChidlowL E RandleR A KellyPrecision cut liver slices represent an encouraging ex vivo method to understand the pathogenesis of liver disease alongside drug induced liver injury. Despite being more physiologically relevant compared to in vitro models, precision cut liver slices are limited by the availability of healthy human tissue and experimental variability. Internal oxygen concentration and media composition govern the longevity and viability of the slices during the culture period and as such, a variety of approaches have been taken to maximise the appropriateness of the internal oxygen concentrations across the slice. The aim of this study was to predict whether it is possible to generate a physiologically relevant oxygen gradient of 35-65mmHg across a precision cut liver slice using mathematical modelling. Simulations explore how the internal oxygen concentration changes as a function of the diameter of the slice, the position inside the well and the external incubator oxygen concentration. The model predicts that the desired oxygen gradient may be achieved using a 5mm diameter slice at atmospheric oxygen concentrations, provided that the slice is positioned at a certain height within the well of a 12-well plate.https://doi.org/10.1371/journal.pone.0275788
spellingShingle S J Chidlow
L E Randle
R A Kelly
Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.
PLoS ONE
title Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.
title_full Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.
title_fullStr Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.
title_full_unstemmed Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.
title_short Predicting physiologically-relevant oxygen concentrations in precision-cut liver slices using mathematical modelling.
title_sort predicting physiologically relevant oxygen concentrations in precision cut liver slices using mathematical modelling
url https://doi.org/10.1371/journal.pone.0275788
work_keys_str_mv AT sjchidlow predictingphysiologicallyrelevantoxygenconcentrationsinprecisioncutliverslicesusingmathematicalmodelling
AT lerandle predictingphysiologicallyrelevantoxygenconcentrationsinprecisioncutliverslicesusingmathematicalmodelling
AT rakelly predictingphysiologicallyrelevantoxygenconcentrationsinprecisioncutliverslicesusingmathematicalmodelling