Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors

Composite bonded structure is a prevalent portion of today’s aircraft structure. Adequate bond integrity is a critical aspect of fabrication and service, especially since many of today’s structural bonds are critical for flight safety. Over the last decade, non-destructive bond evaluation techniques...

Full description

Bibliographic Details
Main Authors: Steven P. Caldwell, Donald W. Radford
Format: Article
Language:English
Published: MDPI AG 2023-02-01
Series:Journal of Composites Science
Subjects:
Online Access:https://www.mdpi.com/2504-477X/7/2/53
_version_ 1797620129516748800
author Steven P. Caldwell
Donald W. Radford
author_facet Steven P. Caldwell
Donald W. Radford
author_sort Steven P. Caldwell
collection DOAJ
description Composite bonded structure is a prevalent portion of today’s aircraft structure. Adequate bond integrity is a critical aspect of fabrication and service, especially since many of today’s structural bonds are critical for flight safety. Over the last decade, non-destructive bond evaluation techniques have improved but still cannot detect a structurally weak bond that exhibits full adherend/adhesive contact. The result is that expensive and time-consuming structural proof testing continues to be required to verify bond integrity. The objective of this work is to investigate the feasibility of bondline integrity monitoring using piezoelectric sensors, embedded at different locations within the composite joint, and to assess the benefits of monitoring the thickness mode in addition to the radial mode. Experiments and analyses are performed on single lap shear composite joints, with and without embedded sensors, subjected to incrementally increasing tensile loads. The results indicate that the embedded piezoelectric sensors measure a change in the resonance in both the radial and thickness mode during incremental loading and that the thickness resonance shows enhanced sensitivity to impending failure. Thus, it is demonstrated that monitoring both modes of the piezoelectric sensor provides addition details for prognostic performance evaluation.
first_indexed 2024-03-11T08:37:06Z
format Article
id doaj.art-6a8f4aa9ccf8419398efd52966650952
institution Directory Open Access Journal
issn 2504-477X
language English
last_indexed 2024-03-11T08:37:06Z
publishDate 2023-02-01
publisher MDPI AG
record_format Article
series Journal of Composites Science
spelling doaj.art-6a8f4aa9ccf8419398efd529666509522023-11-16T21:23:29ZengMDPI AGJournal of Composites Science2504-477X2023-02-01725310.3390/jcs7020053Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance SensorsSteven P. Caldwell0Donald W. Radford1Composite Materials, Manufacture and Structures Laboratory, Colorado State University, Fort Collins, CO 80523, USAComposite Materials, Manufacture and Structures Laboratory, Colorado State University, Fort Collins, CO 80523, USAComposite bonded structure is a prevalent portion of today’s aircraft structure. Adequate bond integrity is a critical aspect of fabrication and service, especially since many of today’s structural bonds are critical for flight safety. Over the last decade, non-destructive bond evaluation techniques have improved but still cannot detect a structurally weak bond that exhibits full adherend/adhesive contact. The result is that expensive and time-consuming structural proof testing continues to be required to verify bond integrity. The objective of this work is to investigate the feasibility of bondline integrity monitoring using piezoelectric sensors, embedded at different locations within the composite joint, and to assess the benefits of monitoring the thickness mode in addition to the radial mode. Experiments and analyses are performed on single lap shear composite joints, with and without embedded sensors, subjected to incrementally increasing tensile loads. The results indicate that the embedded piezoelectric sensors measure a change in the resonance in both the radial and thickness mode during incremental loading and that the thickness resonance shows enhanced sensitivity to impending failure. Thus, it is demonstrated that monitoring both modes of the piezoelectric sensor provides addition details for prognostic performance evaluation.https://www.mdpi.com/2504-477X/7/2/53structural health monitoringsingle lap shear jointpiezoelectric sensorcomposite bondelectromechanical impedancefinite element modeling
spellingShingle Steven P. Caldwell
Donald W. Radford
Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors
Journal of Composites Science
structural health monitoring
single lap shear joint
piezoelectric sensor
composite bond
electromechanical impedance
finite element modeling
title Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors
title_full Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors
title_fullStr Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors
title_full_unstemmed Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors
title_short Composite Single Lap Shear Joint Integrity Monitoring via Embedded Electromechanical Impedance Sensors
title_sort composite single lap shear joint integrity monitoring via embedded electromechanical impedance sensors
topic structural health monitoring
single lap shear joint
piezoelectric sensor
composite bond
electromechanical impedance
finite element modeling
url https://www.mdpi.com/2504-477X/7/2/53
work_keys_str_mv AT stevenpcaldwell compositesinglelapshearjointintegritymonitoringviaembeddedelectromechanicalimpedancesensors
AT donaldwradford compositesinglelapshearjointintegritymonitoringviaembeddedelectromechanicalimpedancesensors