Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads

Currently, energy policy is associated with the increase in the share of renewable sources in systemic energy production. Due to this trend, coal-fired power units must increase their work flexibility. Adapting a coal power plant to work with a lower load often causes the issue of maintaining the te...

Full description

Bibliographic Details
Main Authors: Michalina Kurkus-Gruszecka, Piotr Krawczyk, Janusz Lewandowski
Format: Article
Language:English
Published: MDPI AG 2021-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/15/4420
_version_ 1827686577200955392
author Michalina Kurkus-Gruszecka
Piotr Krawczyk
Janusz Lewandowski
author_facet Michalina Kurkus-Gruszecka
Piotr Krawczyk
Janusz Lewandowski
author_sort Michalina Kurkus-Gruszecka
collection DOAJ
description Currently, energy policy is associated with the increase in the share of renewable sources in systemic energy production. Due to this trend, coal-fired power units must increase their work flexibility. Adapting a coal power plant to work with a lower load often causes the issue of maintaining the temperature before the selective catalytic reduction (SCR) installation at a sufficiently high level. This paper presents a CFD analysis of the mixing area of two flue gas streams before the SCR installation with various methods for mixing flue gas streams. The novelty of the work is mixing the flue gas streams of different temperatures using a flap shape developed by the authors. A series of numerical simulations were performed to develop the location and method of introducing the higher temperature gas, obtaining a uniform distribution of the exhaust gas temperature. The simulation scheme was applied to a series of geometrical modifications of the boundary conditions. The tested solution using only a single, straight flap in the flue gas duct allows the amplitude to be reduced from 298 K to 144 K. As a result of the research, a mixing flap design was developed to reduce the initial temperature amplitude of the flue gas streams from 298 K to 43 K.
first_indexed 2024-03-10T09:17:02Z
format Article
id doaj.art-6a97bdf2e8d04de587091b08d57c271e
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T09:17:02Z
publishDate 2021-07-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-6a97bdf2e8d04de587091b08d57c271e2023-11-22T05:32:45ZengMDPI AGEnergies1996-10732021-07-011415442010.3390/en14154420Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum LoadsMichalina Kurkus-Gruszecka0Piotr Krawczyk1Janusz Lewandowski2Institute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 21/25, 00-665 Warsaw, PolandInstitute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 21/25, 00-665 Warsaw, PolandInstitute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 21/25, 00-665 Warsaw, PolandCurrently, energy policy is associated with the increase in the share of renewable sources in systemic energy production. Due to this trend, coal-fired power units must increase their work flexibility. Adapting a coal power plant to work with a lower load often causes the issue of maintaining the temperature before the selective catalytic reduction (SCR) installation at a sufficiently high level. This paper presents a CFD analysis of the mixing area of two flue gas streams before the SCR installation with various methods for mixing flue gas streams. The novelty of the work is mixing the flue gas streams of different temperatures using a flap shape developed by the authors. A series of numerical simulations were performed to develop the location and method of introducing the higher temperature gas, obtaining a uniform distribution of the exhaust gas temperature. The simulation scheme was applied to a series of geometrical modifications of the boundary conditions. The tested solution using only a single, straight flap in the flue gas duct allows the amplitude to be reduced from 298 K to 144 K. As a result of the research, a mixing flap design was developed to reduce the initial temperature amplitude of the flue gas streams from 298 K to 43 K.https://www.mdpi.com/1996-1073/14/15/4420flue gas bypassflue gas mixingflue gas temperature before SCRlow-load power boiler operationpower plant flexibility
spellingShingle Michalina Kurkus-Gruszecka
Piotr Krawczyk
Janusz Lewandowski
Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads
Energies
flue gas bypass
flue gas mixing
flue gas temperature before SCR
low-load power boiler operation
power plant flexibility
title Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads
title_full Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads
title_fullStr Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads
title_full_unstemmed Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads
title_short Numerical Analysis on the Flue Gas Temperature Maintenance System of a Solid Fuel-Fired Boiler Operating at Minimum Loads
title_sort numerical analysis on the flue gas temperature maintenance system of a solid fuel fired boiler operating at minimum loads
topic flue gas bypass
flue gas mixing
flue gas temperature before SCR
low-load power boiler operation
power plant flexibility
url https://www.mdpi.com/1996-1073/14/15/4420
work_keys_str_mv AT michalinakurkusgruszecka numericalanalysisonthefluegastemperaturemaintenancesystemofasolidfuelfiredboileroperatingatminimumloads
AT piotrkrawczyk numericalanalysisonthefluegastemperaturemaintenancesystemofasolidfuelfiredboileroperatingatminimumloads
AT januszlewandowski numericalanalysisonthefluegastemperaturemaintenancesystemofasolidfuelfiredboileroperatingatminimumloads