Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography

The quinolizindine alkaloid compound, oxymatrine pesticide, was analysis in the river water samples collected from different agriculture areas in the Iraqi city of Kerbala and also in its formulation using developed reverse-phase high-performance liquid chromatography method. Acetonitrile:methanol (...

Full description

Bibliographic Details
Main Authors: Ihsan M. Shaheed, Saadiyah A. Dhahir
Format: Article
Language:English
Published: Koya University 2020-09-01
Series:ARO-The Scientific Journal of Koya University
Subjects:
Online Access:https://aro.koyauniversity.org/index.php/aro/article/view/666
_version_ 1827849090631729152
author Ihsan M. Shaheed
Saadiyah A. Dhahir
author_facet Ihsan M. Shaheed
Saadiyah A. Dhahir
author_sort Ihsan M. Shaheed
collection DOAJ
description The quinolizindine alkaloid compound, oxymatrine pesticide, was analysis in the river water samples collected from different agriculture areas in the Iraqi city of Kerbala and also in its formulation using developed reverse-phase high-performance liquid chromatography method. Acetonitrile:methanol (60:40 v/v) was chosen as mobile phase at pH (7.0), flow rate 0.5 mL/min, and 20 µL as volume injection. Modified ecological-friendly method, dispersive liquid-liquid microextraction, was used for the extraction of oxymatrine from water samples. Linearity study was constructed from 0.1 to 70 μg/mL at λmax 205 nm. The limit of detection and limit of quantification were 0.025 and 0.082 μg/mL, respectively, and the relative standard deviation (RSD) % was 0.518%. Three spiked levels of concentration (20.0, 40.0, and 70.0 μg/mL) were used for the validation method. The percentage recovery for the three spiked samples was ranged between 98.743 and 99.432 and the RSD% was between 0.051 and 0.202%, the formulation studies of oxymatrine between 99.487 and 99.798, and the RSD% was ranged from 0.045 to 0.057%. The developed method can be used accurately and selectively for the determination of oxymatrine in environmental samples and in the formulation.
first_indexed 2024-03-12T09:57:25Z
format Article
id doaj.art-6b4e8674dfb54e398a0d4e7ad2505827
institution Directory Open Access Journal
issn 2410-9355
2307-549X
language English
last_indexed 2024-03-12T09:57:25Z
publishDate 2020-09-01
publisher Koya University
record_format Article
series ARO-The Scientific Journal of Koya University
spelling doaj.art-6b4e8674dfb54e398a0d4e7ad25058272023-09-02T12:02:10ZengKoya UniversityARO-The Scientific Journal of Koya University2410-93552307-549X2020-09-018210.14500/aro.10666Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid ChromatographyIhsan M. Shaheed0Saadiyah A. Dhahir1Department of Chemistry, Faculty of Science, University of Baghdad,Baghdad, IraqDepartment of Chemistry, Faculty of Science for Women, University of Baghdad, Baghdad, IraqThe quinolizindine alkaloid compound, oxymatrine pesticide, was analysis in the river water samples collected from different agriculture areas in the Iraqi city of Kerbala and also in its formulation using developed reverse-phase high-performance liquid chromatography method. Acetonitrile:methanol (60:40 v/v) was chosen as mobile phase at pH (7.0), flow rate 0.5 mL/min, and 20 µL as volume injection. Modified ecological-friendly method, dispersive liquid-liquid microextraction, was used for the extraction of oxymatrine from water samples. Linearity study was constructed from 0.1 to 70 μg/mL at λmax 205 nm. The limit of detection and limit of quantification were 0.025 and 0.082 μg/mL, respectively, and the relative standard deviation (RSD) % was 0.518%. Three spiked levels of concentration (20.0, 40.0, and 70.0 μg/mL) were used for the validation method. The percentage recovery for the three spiked samples was ranged between 98.743 and 99.432 and the RSD% was between 0.051 and 0.202%, the formulation studies of oxymatrine between 99.487 and 99.798, and the RSD% was ranged from 0.045 to 0.057%. The developed method can be used accurately and selectively for the determination of oxymatrine in environmental samples and in the formulation.https://aro.koyauniversity.org/index.php/aro/article/view/666DispersiveOxymatrineReverse-phase high-performance liquid chromatographyUV visible
spellingShingle Ihsan M. Shaheed
Saadiyah A. Dhahir
Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography
ARO-The Scientific Journal of Koya University
Dispersive
Oxymatrine
Reverse-phase high-performance liquid chromatography
UV visible
title Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography
title_full Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography
title_fullStr Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography
title_full_unstemmed Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography
title_short Extraction and Determination of Oxymatrine Pesticide in Environmental Sample and in its Formulation using High-Performance Liquid Chromatography
title_sort extraction and determination of oxymatrine pesticide in environmental sample and in its formulation using high performance liquid chromatography
topic Dispersive
Oxymatrine
Reverse-phase high-performance liquid chromatography
UV visible
url https://aro.koyauniversity.org/index.php/aro/article/view/666
work_keys_str_mv AT ihsanmshaheed extractionanddeterminationofoxymatrinepesticideinenvironmentalsampleandinitsformulationusinghighperformanceliquidchromatography
AT saadiyahadhahir extractionanddeterminationofoxymatrinepesticideinenvironmentalsampleandinitsformulationusinghighperformanceliquidchromatography