The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy
In this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8...
Main Author: | |
---|---|
Format: | Article |
Language: | Arabic |
Published: |
College of Science for Women, University of Baghdad
2015-12-01
|
Series: | Baghdad Science Journal |
Subjects: | |
Online Access: | http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2115 |
_version_ | 1818144401037197312 |
---|---|
author | Baghdad Science Journal |
author_facet | Baghdad Science Journal |
author_sort | Baghdad Science Journal |
collection | DOAJ |
description | In this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt. |
first_indexed | 2024-12-11T11:46:58Z |
format | Article |
id | doaj.art-6b643c683c42419aaaa9fa96a5a27570 |
institution | Directory Open Access Journal |
issn | 2078-8665 2411-7986 |
language | Arabic |
last_indexed | 2024-12-11T11:46:58Z |
publishDate | 2015-12-01 |
publisher | College of Science for Women, University of Baghdad |
record_format | Article |
series | Baghdad Science Journal |
spelling | doaj.art-6b643c683c42419aaaa9fa96a5a275702022-12-22T01:08:27ZaraCollege of Science for Women, University of BaghdadBaghdad Science Journal2078-86652411-79862015-12-0112410.21123/bsj.12.4.684-690The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V AlloyBaghdad Science JournalIn this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2115Medical materials and Alloys, Electrochemical deposition of Hydroxyapatite Biocompatibilty Improvements |
spellingShingle | Baghdad Science Journal The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy Baghdad Science Journal Medical materials and Alloys, Electrochemical deposition of Hydroxyapatite Biocompatibilty Improvements |
title | The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy |
title_full | The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy |
title_fullStr | The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy |
title_full_unstemmed | The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy |
title_short | The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy |
title_sort | effect of the electrochemical deposition potential variation on the coating of hydroxyatite on commertialy pure titanium cpti and ti 6al 4v alloy |
topic | Medical materials and Alloys, Electrochemical deposition of Hydroxyapatite Biocompatibilty Improvements |
url | http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2115 |
work_keys_str_mv | AT baghdadsciencejournal theeffectoftheelectrochemicaldepositionpotentialvariationonthecoatingofhydroxyatiteoncommertialypuretitaniumcptiandti6al4valloy AT baghdadsciencejournal effectoftheelectrochemicaldepositionpotentialvariationonthecoatingofhydroxyatiteoncommertialypuretitaniumcptiandti6al4valloy |