Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer

Background and purpose: Patients with head and neck (HN) cancer may benefit from proton therapy due to the potential for sparing of normal tissue. For planning of proton therapy, dual-energy CT (DECT) has been shown to provide superior stopping power ratio (SPR) determination in phantom materials an...

Full description

Bibliographic Details
Main Authors: Vicki Trier Taasti, Ludvig Paul Muren, Kenneth Jensen, Jørgen Breede Baltzer Petersen, Jesper Thygesen, Anna Tietze, Cai Grau, David Christoffer Hansen
Format: Article
Language:English
Published: Elsevier 2018-04-01
Series:Physics and Imaging in Radiation Oncology
Online Access:http://www.sciencedirect.com/science/article/pii/S2405631617300842
_version_ 1811322350392573952
author Vicki Trier Taasti
Ludvig Paul Muren
Kenneth Jensen
Jørgen Breede Baltzer Petersen
Jesper Thygesen
Anna Tietze
Cai Grau
David Christoffer Hansen
author_facet Vicki Trier Taasti
Ludvig Paul Muren
Kenneth Jensen
Jørgen Breede Baltzer Petersen
Jesper Thygesen
Anna Tietze
Cai Grau
David Christoffer Hansen
author_sort Vicki Trier Taasti
collection DOAJ
description Background and purpose: Patients with head and neck (HN) cancer may benefit from proton therapy due to the potential for sparing of normal tissue. For planning of proton therapy, dual-energy CT (DECT) has been shown to provide superior stopping power ratio (SPR) determination in phantom materials and organic tissue samples, compared to single-energy CT (SECT). However, the benefit of DECT in HN cancer patients has not yet been investigated. This study therefore compared DECT- and SECT-based SPR estimation for HN cancer patients. Materials and methods: Fourteen HN cancer patients were DECT scanned. Eight patients were scanned using a dual source DECT scanner and six were scanned with a conventional SECT scanner by acquiring two consecutive scans. SECT image sets were computed as a weighted summation of the low and high energy DECT image sets. DECT- and SECT-based SPR maps were derived. Water-equivalent path lengths (WEPLs) through the SPR maps were compared in the eight cases with dual source DECT scans. Mean SPR estimates over region-of-interests (ROIs) in the cranium, brain and eyes were analyzed for all patients. Results: A median WEPL difference of 1.9 mm (1.5%) was found across the eight patients. Statistically significant SPR differences were seen for the ROIs in the brain and eyes, with the SPR estimates based on DECT overall lower than for SECT. Conclusions: Clinically relevant WEPL and SPR differences were found between DECT and SECT, which could imply that the accuracy of treatment planning for proton therapy would benefit from DECT-based SPR estimation. Keywords: Proton therapy, Stopping power ratio, Dual-energy CT, Water-equivalent path length, Head and neck cancer
first_indexed 2024-04-13T13:33:46Z
format Article
id doaj.art-6b68250827f44e3f987860cc6a2d9634
institution Directory Open Access Journal
issn 2405-6316
language English
last_indexed 2024-04-13T13:33:46Z
publishDate 2018-04-01
publisher Elsevier
record_format Article
series Physics and Imaging in Radiation Oncology
spelling doaj.art-6b68250827f44e3f987860cc6a2d96342022-12-22T02:44:51ZengElsevierPhysics and Imaging in Radiation Oncology2405-63162018-04-0161419Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancerVicki Trier Taasti0Ludvig Paul Muren1Kenneth Jensen2Jørgen Breede Baltzer Petersen3Jesper Thygesen4Anna Tietze5Cai Grau6David Christoffer Hansen7Dept. of Medical Physics, Aarhus University Hospital, Aarhus, Denmark; Corresponding author.Dept. of Medical Physics, Aarhus University Hospital, Aarhus, DenmarkDept. of Oncology, Aarhus University Hospital, Aarhus, DenmarkDept. of Medical Physics, Aarhus University Hospital, Aarhus, DenmarkDept. of Clinical Engineering, Aarhus University Hospital, Aarhus, DenmarkDept. of Neuroradiology, Aarhus University Hospital, Aarhus, Denmark; Institute of Neuroradiology, Charité – Universitätsmedizin Berlin, Berlin, GermanyDept. of Oncology, Aarhus University Hospital, Aarhus, DenmarkDept. of Medical Physics, Aarhus University Hospital, Aarhus, DenmarkBackground and purpose: Patients with head and neck (HN) cancer may benefit from proton therapy due to the potential for sparing of normal tissue. For planning of proton therapy, dual-energy CT (DECT) has been shown to provide superior stopping power ratio (SPR) determination in phantom materials and organic tissue samples, compared to single-energy CT (SECT). However, the benefit of DECT in HN cancer patients has not yet been investigated. This study therefore compared DECT- and SECT-based SPR estimation for HN cancer patients. Materials and methods: Fourteen HN cancer patients were DECT scanned. Eight patients were scanned using a dual source DECT scanner and six were scanned with a conventional SECT scanner by acquiring two consecutive scans. SECT image sets were computed as a weighted summation of the low and high energy DECT image sets. DECT- and SECT-based SPR maps were derived. Water-equivalent path lengths (WEPLs) through the SPR maps were compared in the eight cases with dual source DECT scans. Mean SPR estimates over region-of-interests (ROIs) in the cranium, brain and eyes were analyzed for all patients. Results: A median WEPL difference of 1.9 mm (1.5%) was found across the eight patients. Statistically significant SPR differences were seen for the ROIs in the brain and eyes, with the SPR estimates based on DECT overall lower than for SECT. Conclusions: Clinically relevant WEPL and SPR differences were found between DECT and SECT, which could imply that the accuracy of treatment planning for proton therapy would benefit from DECT-based SPR estimation. Keywords: Proton therapy, Stopping power ratio, Dual-energy CT, Water-equivalent path length, Head and neck cancerhttp://www.sciencedirect.com/science/article/pii/S2405631617300842
spellingShingle Vicki Trier Taasti
Ludvig Paul Muren
Kenneth Jensen
Jørgen Breede Baltzer Petersen
Jesper Thygesen
Anna Tietze
Cai Grau
David Christoffer Hansen
Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
Physics and Imaging in Radiation Oncology
title Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
title_full Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
title_fullStr Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
title_full_unstemmed Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
title_short Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
title_sort comparison of single and dual energy ct for stopping power determination in proton therapy of head and neck cancer
url http://www.sciencedirect.com/science/article/pii/S2405631617300842
work_keys_str_mv AT vickitriertaasti comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT ludvigpaulmuren comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT kennethjensen comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT jørgenbreedebaltzerpetersen comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT jesperthygesen comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT annatietze comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT caigrau comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer
AT davidchristofferhansen comparisonofsingleanddualenergyctforstoppingpowerdeterminationinprotontherapyofheadandneckcancer