РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ
The problems of distributed voltage control in electrical grids (EGs) with renewable sources of electric energy with converter-interfaced generation (CIG). It is proposed to control the EGs modes by controlling the reactive power of converter-interfaced generation. It is proposed to use the mean sq...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Electrodynamics of the National Academy of Sciences of Ukraine
2023-12-01
|
Series: | Праці Інституту електродинаміки Національної академії наук України |
Subjects: | |
Online Access: | https://prc.ied.org.ua/index.php/proceedings/article/view/296 |
_version_ | 1797383394908176384 |
---|---|
author | І.В. Блінов І.В. Трач О.Б. Рибіна |
author_facet | І.В. Блінов І.В. Трач О.Б. Рибіна |
author_sort | І.В. Блінов |
collection | DOAJ |
description | The problems of distributed voltage control in electrical grids (EGs) with renewable sources of electric energy with converter-interfaced generation (CIG). It is proposed to control the EGs modes by controlling the reactive power of converter-interfaced generation. It is proposed to use the mean square deviation of the voltage in the converter inter-faced generation (CIG) installation nodes as the criterion of the target function. The extremum seeking control method was used to solve the problem of dynamic optimization with daily changes in the parameters of the electric network, namely the loads and active power of renewable sources. The examples provided have shown the improvement of the voltage in the EG at different levels of reactive power generation limitation according to the norms of the standard EN50549-1:2019. The optimal values of the average daily value of the rms deviation of the voltage of the ieee33 test EM were obtained with a significant penetration of the RES power. Bibl. 12, fig. 4, table. |
first_indexed | 2024-03-08T21:20:19Z |
format | Article |
id | doaj.art-6bb3011f0739403580388f8697b094eb |
institution | Directory Open Access Journal |
issn | 1727-9895 2786-7064 |
language | English |
last_indexed | 2024-03-08T21:20:19Z |
publishDate | 2023-12-01 |
publisher | Institute of Electrodynamics of the National Academy of Sciences of Ukraine |
record_format | Article |
series | Праці Інституту електродинаміки Національної академії наук України |
spelling | doaj.art-6bb3011f0739403580388f8697b094eb2023-12-21T11:27:37ZengInstitute of Electrodynamics of the National Academy of Sciences of UkraineПраці Інституту електродинаміки Національної академії наук України1727-98952786-70642023-12-01202366510https://doi.org/10.15407/publishing2023.66.005РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇІ.В. Блінов0https://orcid.org/0000-0001-8010-5301І.В. Трач1https://orcid.org/0000-0002-3345-2324О.Б. Рибіна2https://orcid.org/0000-0002-5744-3422ІнститутелектродинамікиНАНУкраїни, пр. Берестейський, 56, Київ, 03057, УкраїнаІнститутелектродинамікиНАНУкраїни, пр. Берестейський, 56, Київ, 03057, УкраїнаІнститутелектродинамікиНАНУкраїни, пр. Берестейський, 56, Київ, 03057, УкраїнаThe problems of distributed voltage control in electrical grids (EGs) with renewable sources of electric energy with converter-interfaced generation (CIG). It is proposed to control the EGs modes by controlling the reactive power of converter-interfaced generation. It is proposed to use the mean square deviation of the voltage in the converter inter-faced generation (CIG) installation nodes as the criterion of the target function. The extremum seeking control method was used to solve the problem of dynamic optimization with daily changes in the parameters of the electric network, namely the loads and active power of renewable sources. The examples provided have shown the improvement of the voltage in the EG at different levels of reactive power generation limitation according to the norms of the standard EN50549-1:2019. The optimal values of the average daily value of the rms deviation of the voltage of the ieee33 test EM were obtained with a significant penetration of the RES power. Bibl. 12, fig. 4, table.https://prc.ied.org.ua/index.php/proceedings/article/view/296distributed voltage controlconverter interfaced generationextremum seeking control method |
spellingShingle | І.В. Блінов І.В. Трач О.Б. Рибіна РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ Праці Інституту електродинаміки Національної академії наук України distributed voltage control converter interfaced generation extremum seeking control method |
title | РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ |
title_full | РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ |
title_fullStr | РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ |
title_full_unstemmed | РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ |
title_short | РОЗПОДІЛЕНЕ РЕГУЛЮВАННЯ НАПРУГИ РОЗПОДІЛЬЧОЇ ЕЛЕКТРОМЕРЕЖІ З ВІДНОВЛЮВАНИМИ ДЖЕРЕЛАМИ ЕЛЕКТРОЕНЕРГІЇ |
title_sort | розподілене регулювання напруги розподільчої електромережі з відновлюваними джерелами електроенергії |
topic | distributed voltage control converter interfaced generation extremum seeking control method |
url | https://prc.ied.org.ua/index.php/proceedings/article/view/296 |
work_keys_str_mv | AT ívblínov rozpodíleneregulûvannânaprugirozpodílʹčoíelektromerežízvídnovlûvanimidžerelamielektroenergíí AT ívtrač rozpodíleneregulûvannânaprugirozpodílʹčoíelektromerežízvídnovlûvanimidžerelamielektroenergíí AT obribína rozpodíleneregulûvannânaprugirozpodílʹčoíelektromerežízvídnovlûvanimidžerelamielektroenergíí |