Numerical study on the straight, helical and spiral capillary tube for the CO2 refrigerant
A numerical study has been carried out for straight, spiral and helical capillary tubes and their performance has been compared with CO2 refrigerant. The numerical models are developed based on the fundamental conservation principles of mass, momentum, and energy. Within this, outer loop, the ordin...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Saint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University)
2022-08-01
|
Series: | Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki |
Subjects: | |
Online Access: | https://ntv.ifmo.ru/file/article/21374.pdf |
Summary: | A numerical study has been carried out for straight, spiral and helical capillary tubes and their performance has been
compared with CO2 refrigerant. The numerical models are developed based on the fundamental conservation principles of mass, momentum, and energy. Within this, outer loop, the ordinary differential equations are solved from the inlet to the exit of the capillary tube. The study has been carried out to calculate the mass flow rate by bisection method where the mass is iteratively calculated at the specified capillary length or vice versa. In-house coding programming employs the finite difference approach for numerical solutions. The characterization of the capillary tube has been done by calculating the length for the given mass or by calculating mass for the given length. The comparison of the straight capillary with helical capillary tube (50 mm coil diameter) and spiral capillary tube (50 mm pitch) has been reported. For a change in tube diameter, surface roughness, and length, the percentage reduction in mass flow rate in capillary tubes (straight, helical, and spiral) is calculated. The percentage reduction in mass in a helical capillary tube compared to the straight capillary tube is about 7–9 %. The percentage reduction in mass in a spiral tube compared to the straight capillary tube
is nearly 23–26 %. Additionally, the percentage reduction in mass in a spiral tube compared to the helical capillary tube
is almost 17–19 %. Additionally, the percentage reduction in length in a spiral tube compared to straight capillary tube
ranges from 37 % to 43 %. Similarly, the percentage reduction in length in a spiral tube compared to helical capillary tube is ranging from 25 % to 32 %. |
---|---|