DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD
Unfortunately, motor current signature analysis (MCSA) cannot detect the small degrees of the purely static eccentricity (SE) defects, while the air-gap magnetic flux signature analysis (FSA) is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE) m...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
El Oued University
2013-06-01
|
Series: | Journal of Fundamental and Applied Sciences |
Online Access: | http://old.jfas.info/index.php/JFAS/article/view/157-333/pdf |
_version_ | 1818549720653496320 |
---|---|
author | N. Halem S. E. Zouzou K. Srairi S. Guedidi F. A. Abood |
author_facet | N. Halem S. E. Zouzou K. Srairi S. Guedidi F. A. Abood |
author_sort | N. Halem |
collection | DOAJ |
description | Unfortunately, motor current signature analysis (MCSA) cannot detect the small degrees of the purely static eccentricity (SE) defects, while the air-gap magnetic flux signature analysis (FSA) is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE) method. In order to show the impact of magnetic saturation upon the diagnosis of SE fault, the analysis is carried out for saturated induction motors. The index signatures of static eccentricity fault around fundamental and PSHs are detected successfully for saturated motor. |
first_indexed | 2024-12-12T08:37:02Z |
format | Article |
id | doaj.art-6ce9f3bd92064540b3f72e057cbb2efd |
institution | Directory Open Access Journal |
issn | 1112-9867 |
language | English |
last_indexed | 2024-12-12T08:37:02Z |
publishDate | 2013-06-01 |
publisher | El Oued University |
record_format | Article |
series | Journal of Fundamental and Applied Sciences |
spelling | doaj.art-6ce9f3bd92064540b3f72e057cbb2efd2022-12-22T00:30:54ZengEl Oued UniversityJournal of Fundamental and Applied Sciences1112-98672013-06-01515368DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHODN. HalemS. E. ZouzouK. SrairiS. GuedidiF. A. AboodUnfortunately, motor current signature analysis (MCSA) cannot detect the small degrees of the purely static eccentricity (SE) defects, while the air-gap magnetic flux signature analysis (FSA) is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE) method. In order to show the impact of magnetic saturation upon the diagnosis of SE fault, the analysis is carried out for saturated induction motors. The index signatures of static eccentricity fault around fundamental and PSHs are detected successfully for saturated motor.http://old.jfas.info/index.php/JFAS/article/view/157-333/pdf |
spellingShingle | N. Halem S. E. Zouzou K. Srairi S. Guedidi F. A. Abood DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD Journal of Fundamental and Applied Sciences |
title | DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD |
title_full | DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD |
title_fullStr | DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD |
title_full_unstemmed | DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD |
title_short | DETECTION OF STATIC ECCENTRICITY FAULT IN SATURATED INDUCTION MOTORS BY AIR-GAP MAGNETIC FLUX SIGNATURE ANALYSIS USING FINITE ELEMENT METHOD |
title_sort | detection of static eccentricity fault in saturated induction motors by air gap magnetic flux signature analysis using finite element method |
url | http://old.jfas.info/index.php/JFAS/article/view/157-333/pdf |
work_keys_str_mv | AT nhalem detectionofstaticeccentricityfaultinsaturatedinductionmotorsbyairgapmagneticfluxsignatureanalysisusingfiniteelementmethod AT sezouzou detectionofstaticeccentricityfaultinsaturatedinductionmotorsbyairgapmagneticfluxsignatureanalysisusingfiniteelementmethod AT ksrairi detectionofstaticeccentricityfaultinsaturatedinductionmotorsbyairgapmagneticfluxsignatureanalysisusingfiniteelementmethod AT sguedidi detectionofstaticeccentricityfaultinsaturatedinductionmotorsbyairgapmagneticfluxsignatureanalysisusingfiniteelementmethod AT faabood detectionofstaticeccentricityfaultinsaturatedinductionmotorsbyairgapmagneticfluxsignatureanalysisusingfiniteelementmethod |