Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum

The aim of the current study was to determine the effectiveness of two surgical techniques regarding cow respiratory rates, heart rates, and rumination time using two sensors: an experimental device created by the Institute of Biomedical Engineering of Kaunas University of Technology (Lithuania) and...

Full description

Bibliographic Details
Main Authors: Ramūnas Antanaitis, Vida Juozaitienė, Mindaugas Televičius, Dovilė Malašauskienė, Mantvydas Merkis, Eitvydas Merkis, Walter Baumgartner
Format: Article
Language:English
Published: MDPI AG 2020-08-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/16/4416
_version_ 1797559546031374336
author Ramūnas Antanaitis
Vida Juozaitienė
Mindaugas Televičius
Dovilė Malašauskienė
Mantvydas Merkis
Eitvydas Merkis
Walter Baumgartner
author_facet Ramūnas Antanaitis
Vida Juozaitienė
Mindaugas Televičius
Dovilė Malašauskienė
Mantvydas Merkis
Eitvydas Merkis
Walter Baumgartner
author_sort Ramūnas Antanaitis
collection DOAJ
description The aim of the current study was to determine the effectiveness of two surgical techniques regarding cow respiratory rates, heart rates, and rumination time using two sensors: an experimental device created by the Institute of Biomedical Engineering of Kaunas University of Technology (Lithuania) and the Hi-Tag rumination monitoring system (SCR) produced by SCR Engineers Ltd., Netanya, Israel. The cows were divided into two groups: the PA1 group, containing cows treated by percutaneous abomasopexy (n = 10), and the RSO2 group, containing cows treated by right side omentopexy (n = 8). For the control group (KH), according to the principle of analogs (number of lactations, breed, and days in milk), we selected clinically healthy cows (n = 9). After the surgical treatment for the abomasal displacement, the experimental device was applied for the recording of the heart and breathing rates, 12 h tracking of the rumination time was implemented using the SCR, and the body temperature was measured. After 12 h, the blood was taken for biochemical and morphological tests. With the help of experimental sensors, we found that the more efficient abomasal displacement surgical method was the right side omentopexy: During the first 12 h after right side omentopexy, we found a 5.19 beats/min lower (1.10 times lower) average value of the respiratory rate, a 1.13 times higher level of the heart rate, a 0.15 °C higher temperature, and a 3.29 times lower rumination time compared to the clinically healthy cows. During the first 12 h after percutaneous abomasopexy, we found a 5.19 beats/min higher (1.07 times) average value of heart rate, a 0.02 °C higher temperature, a 6.21 times lower rumination time, and a 0.12 beats/min lower (1.01 times lower) average value of respiratory rate compared to the clinically healthy cows.
first_indexed 2024-03-10T17:47:53Z
format Article
id doaj.art-6cfb1ba4aea040feba53c9e013da5b21
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T17:47:53Z
publishDate 2020-08-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-6cfb1ba4aea040feba53c9e013da5b212023-11-20T09:28:34ZengMDPI AGSensors1424-82202020-08-012016441610.3390/s20164416Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the AbomasumRamūnas Antanaitis0Vida Juozaitienė1Mindaugas Televičius2Dovilė Malašauskienė3Mantvydas Merkis4Eitvydas Merkis5Walter Baumgartner6Large Animal Clinic, Veterinary Academy, Lithuanian University of Health Sciences, Tilžės str 18, LT-47181 Kaunas, LithuaniaDepartment of Animal Breeding, Veterinary Academy, Lithuanian University of Health Sciences, Tilžės str 18, LT-47181 Kaunas, LithuaniaLarge Animal Clinic, Veterinary Academy, Lithuanian University of Health Sciences, Tilžės str 18, LT-47181 Kaunas, LithuaniaLarge Animal Clinic, Veterinary Academy, Lithuanian University of Health Sciences, Tilžės str 18, LT-47181 Kaunas, LithuaniaPhysics Department, Kaunas University of Technology, K. Donelaičio str 73, LT-44249 Kaunas, LithuaniaLarge Animal Clinic, Veterinary Academy, Lithuanian University of Health Sciences, Tilžės str 18, LT-47181 Kaunas, LithuaniaUniversity Clinic for Ruminants, University of Veterinary Medicine, Veterinaerplatz 1, A-1210 Vienna, AustriaThe aim of the current study was to determine the effectiveness of two surgical techniques regarding cow respiratory rates, heart rates, and rumination time using two sensors: an experimental device created by the Institute of Biomedical Engineering of Kaunas University of Technology (Lithuania) and the Hi-Tag rumination monitoring system (SCR) produced by SCR Engineers Ltd., Netanya, Israel. The cows were divided into two groups: the PA1 group, containing cows treated by percutaneous abomasopexy (n = 10), and the RSO2 group, containing cows treated by right side omentopexy (n = 8). For the control group (KH), according to the principle of analogs (number of lactations, breed, and days in milk), we selected clinically healthy cows (n = 9). After the surgical treatment for the abomasal displacement, the experimental device was applied for the recording of the heart and breathing rates, 12 h tracking of the rumination time was implemented using the SCR, and the body temperature was measured. After 12 h, the blood was taken for biochemical and morphological tests. With the help of experimental sensors, we found that the more efficient abomasal displacement surgical method was the right side omentopexy: During the first 12 h after right side omentopexy, we found a 5.19 beats/min lower (1.10 times lower) average value of the respiratory rate, a 1.13 times higher level of the heart rate, a 0.15 °C higher temperature, and a 3.29 times lower rumination time compared to the clinically healthy cows. During the first 12 h after percutaneous abomasopexy, we found a 5.19 beats/min higher (1.07 times) average value of heart rate, a 0.02 °C higher temperature, a 6.21 times lower rumination time, and a 0.12 beats/min lower (1.01 times lower) average value of respiratory rate compared to the clinically healthy cows.https://www.mdpi.com/1424-8220/20/16/4416experimental sensordairy cowsabomasal displacement
spellingShingle Ramūnas Antanaitis
Vida Juozaitienė
Mindaugas Televičius
Dovilė Malašauskienė
Mantvydas Merkis
Eitvydas Merkis
Walter Baumgartner
Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
Sensors
experimental sensor
dairy cows
abomasal displacement
title Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_full Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_fullStr Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_full_unstemmed Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_short Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_sort preliminary experiment using sensors for cow health monitoring after surgical treatment for the left displacement of the abomasum
topic experimental sensor
dairy cows
abomasal displacement
url https://www.mdpi.com/1424-8220/20/16/4416
work_keys_str_mv AT ramunasantanaitis preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT vidajuozaitiene preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT mindaugastelevicius preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT dovilemalasauskiene preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT mantvydasmerkis preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT eitvydasmerkis preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT walterbaumgartner preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum