Calculation method of stabilizing piles with broadened top at the built-in section
In order to solve lacking of horizontal bearing capacity of local strata resistance before built-in section of the stabilizing pile, stabilizing piles with locally broadened top at the built-in section is proposed as a new type pile. According to analysis model of laterally loaded beam on elastic fo...
Main Authors: | Shirong DENG, Shiguo XIAO |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of The Chinese Journal of Geological Hazard and Control
2022-08-01
|
Series: | Zhongguo dizhi zaihai yu fangzhi xuebao |
Subjects: | |
Online Access: | https://www.zgdzzhyfzxb.com/en/article/doi/10.16031/j.cnki.issn.1003-8035.202107006 |
Similar Items
-
Simplified calculation method and stability analysis of top beam cooperative pile–anchor supporting slope structure
by: Tianzhong Ma, et al.
Published: (2022-09-01) -
Determination of pile damage by top measurements /
by: 407917 Rausche, Frank, et al. -
Comparative Analysis of Kazakhstani and European Design Specifications: Raft Foundation, Pile Foundation, and Piled Raft Foundation
by: Assel Zhanabayeva, et al.
Published: (2021-03-01) -
Friction capability of steel H-Pile with corrugated web section /
by: 314262 Ong, Ka Thiam
Published: (2004) -
Friction capability of steel H-Pile with corrugated web section [electronic resource] /
by: Ong, Ka Thiam, author, et al.
Published: (2004)