USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY
RELEVANCE. Our report is based on the results of investigation of 285 patients with different types of pelvic injury. due to clinic-anatomic variations of pelvic injuries and treatment tactics of victims were divided to three groups according to classification of the Center documentations AO. In the...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Sklifosovsky Research Institute for Emergency Medicine, Public Healthcare Institution of Moscow Healthcare Department
2016-03-01
|
Series: | Неотложная медицинская помощь |
Subjects: | |
Online Access: | https://www.jnmp.ru/jour/article/view/186 |
_version_ | 1826564792648728576 |
---|---|
author | A. B. Tilyakov E. Y. Valiev B. S. Ubaydullaev |
author_facet | A. B. Tilyakov E. Y. Valiev B. S. Ubaydullaev |
author_sort | A. B. Tilyakov |
collection | DOAJ |
description | RELEVANCE. Our report is based on the results of investigation of 285 patients with different types of pelvic injury. due to clinic-anatomic variations of pelvic injuries and treatment tactics of victims were divided to three groups according to classification of the Center documentations AO. In the diagnosis of pelvic injuries method of multispiral computered tomography with modeling of volume images in 3d regime was used widely. In patients with combined injuries extra ostheosynthesis of pelvic bones was carried out after liquidation of dominant pathology. Ostheosynthesis of pelvic injuries was conducted using rod apparatus, offered by our clinic with stabilization and reposition of pelvic bone fragments. developed minimally invasive method with minimally traumatization of soft issues allows making ostheosynthesis in acute and early periods of traumatic disease at combined injury. |
first_indexed | 2024-03-12T18:15:15Z |
format | Article |
id | doaj.art-6d2b99aad0d846a595b1547a18671873 |
institution | Directory Open Access Journal |
issn | 2223-9022 2541-8017 |
language | Russian |
last_indexed | 2025-03-14T10:25:29Z |
publishDate | 2016-03-01 |
publisher | Sklifosovsky Research Institute for Emergency Medicine, Public Healthcare Institution of Moscow Healthcare Department |
record_format | Article |
series | Неотложная медицинская помощь |
spelling | doaj.art-6d2b99aad0d846a595b1547a186718732025-03-02T11:06:16ZrusSklifosovsky Research Institute for Emergency Medicine, Public Healthcare Institution of Moscow Healthcare DepartmentНеотложная медицинская помощь2223-90222541-80172016-03-01023237184USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURYA. B. Tilyakov0E. Y. Valiev1B. S. Ubaydullaev2The republican Science Centre of Emergency Medical Care of the Healthcare Ministry of the RUz, TashkentThe republican Science Centre of Emergency Medical Care of the Healthcare Ministry of the RUz, TashkentThe republican Science Centre of Emergency Medical Care of the Healthcare Ministry of the RUz, TashkentRELEVANCE. Our report is based on the results of investigation of 285 patients with different types of pelvic injury. due to clinic-anatomic variations of pelvic injuries and treatment tactics of victims were divided to three groups according to classification of the Center documentations AO. In the diagnosis of pelvic injuries method of multispiral computered tomography with modeling of volume images in 3d regime was used widely. In patients with combined injuries extra ostheosynthesis of pelvic bones was carried out after liquidation of dominant pathology. Ostheosynthesis of pelvic injuries was conducted using rod apparatus, offered by our clinic with stabilization and reposition of pelvic bone fragments. developed minimally invasive method with minimally traumatization of soft issues allows making ostheosynthesis in acute and early periods of traumatic disease at combined injury.https://www.jnmp.ru/jour/article/view/186pelvic injuriesconcomitant injuryrod apparatus |
spellingShingle | A. B. Tilyakov E. Y. Valiev B. S. Ubaydullaev USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY Неотложная медицинская помощь pelvic injuries concomitant injury rod apparatus |
title | USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY |
title_full | USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY |
title_fullStr | USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY |
title_full_unstemmed | USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY |
title_short | USING OF ROD APPARATUS OF EXTERNAL FIXATION IN COMPLEX TREATMENT OF NO STABLE FRACTURES OF PELVIC BONES AT COMBINED INJURY |
title_sort | using of rod apparatus of external fixation in complex treatment of no stable fractures of pelvic bones at combined injury |
topic | pelvic injuries concomitant injury rod apparatus |
url | https://www.jnmp.ru/jour/article/view/186 |
work_keys_str_mv | AT abtilyakov usingofrodapparatusofexternalfixationincomplextreatmentofnostablefracturesofpelvicbonesatcombinedinjury AT eyvaliev usingofrodapparatusofexternalfixationincomplextreatmentofnostablefracturesofpelvicbonesatcombinedinjury AT bsubaydullaev usingofrodapparatusofexternalfixationincomplextreatmentofnostablefracturesofpelvicbonesatcombinedinjury |