A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts

The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for a...

Full description

Bibliographic Details
Main Authors: Yalan Ye, Wenwen He, Yunfei Cheng, Wenxia Huang, Zhilin Zhang
Format: Article
Language:English
Published: MDPI AG 2017-02-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/17/2/385
_version_ 1811185922811625472
author Yalan Ye
Wenwen He
Yunfei Cheng
Wenxia Huang
Zhilin Zhang
author_facet Yalan Ye
Wenwen He
Yunfei Cheng
Wenxia Huang
Zhilin Zhang
author_sort Yalan Ye
collection DOAJ
description The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking.
first_indexed 2024-04-11T13:38:44Z
format Article
id doaj.art-6d41b25b1a9f48bba749d3de389d0906
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-04-11T13:38:44Z
publishDate 2017-02-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-6d41b25b1a9f48bba749d3de389d09062022-12-22T04:21:23ZengMDPI AGSensors1424-82202017-02-0117238510.3390/s17020385s17020385A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion ArtifactsYalan Ye0Wenwen He1Yunfei Cheng2Wenxia Huang3Zhilin Zhang4School of Computer Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, ChinaSchool of Computer Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, ChinaSchool of Computer Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, ChinaWest China Hospital of Sichuan University, Chengdu 610041, ChinaSamsung Research America—Dallas, Richardson, TX 75082, USAThe estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking.http://www.mdpi.com/1424-8220/17/2/385heart rate (HR)photoplethysmography (PPG)motion artifacts (MA)random forest
spellingShingle Yalan Ye
Wenwen He
Yunfei Cheng
Wenxia Huang
Zhilin Zhang
A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
Sensors
heart rate (HR)
photoplethysmography (PPG)
motion artifacts (MA)
random forest
title A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_full A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_fullStr A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_full_unstemmed A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_short A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts
title_sort robust random forest based approach for heart rate monitoring using photoplethysmography signal contaminated by intense motion artifacts
topic heart rate (HR)
photoplethysmography (PPG)
motion artifacts (MA)
random forest
url http://www.mdpi.com/1424-8220/17/2/385
work_keys_str_mv AT yalanye arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT wenwenhe arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT yunfeicheng arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT wenxiahuang arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT zhilinzhang arobustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT yalanye robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT wenwenhe robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT yunfeicheng robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT wenxiahuang robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts
AT zhilinzhang robustrandomforestbasedapproachforheartratemonitoringusingphotoplethysmographysignalcontaminatedbyintensemotionartifacts