Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India

The present work consists of the modeling and analysis of solar photovoltaic panels integrated with electrolyzer bank and Polymer Electrolyte Membrane (PEM) fuel cell stacks for running different appliances of a hospital located in Kolkata for different climatic conditions. Electric power is generat...

Full description

Bibliographic Details
Main Author: Kamaljyoti Talukdar
Format: Article
Language:English
Published: Diponegoro University 2017-06-01
Series:International Journal of Renewable Energy Development
Subjects:
Online Access:https://ijred.cbiore.id/index.php/ijred/article/view/14814
_version_ 1797425059358310400
author Kamaljyoti Talukdar
author_facet Kamaljyoti Talukdar
author_sort Kamaljyoti Talukdar
collection DOAJ
description The present work consists of the modeling and analysis of solar photovoltaic panels integrated with electrolyzer bank and Polymer Electrolyte Membrane (PEM) fuel cell stacks for running different appliances of a hospital located in Kolkata for different climatic conditions. Electric power is generated by an array of solar photovoltaic modules. Excess energy after meeting the requirements of the hospital during peak sunshine hours is supplied to an electrolyzer bank to generate hydrogen gas, which is consumed by the PEM fuel cell stack to support the power requirement during the energy deficit hours. The study reveals that 875 solar photovoltaic modules in parallel each having 2 modules in series of Central Electronics Limited Make PM 150 with a 178.537 kW electrolyzer and 27 PEM fuel cell stacks, each of 382.372 W, can support the energy requirement of a 200 lights (100 W each), 4 pumps (2 kW each), 120 fans(65 W each) and 5 refrigerators (2 kW each)system operated for 16 hours, 2 hours,15 hours and 24 hours respectively. 123 solar photovoltaic modules in parallel each having 2 modules in series of Central Electronics Limited Make PM 150 is needed to run the gas compressor for storing hydrogen in the cylinder during sunshine hours.  Article History: Received Feb 5th 2017; Received in revised form June 2nd 2017; Accepted June 28th 2017; Available online How to Cite This Article: Talukdar, K. (2017). Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata,India. International Journal of Renewable Energy Development, 6(2), 181-191. https://dx.doi.org/10.14710/ijred.6.2.181-191
first_indexed 2024-03-09T08:09:29Z
format Article
id doaj.art-6d5f7a742f1b4a409eeff8ae2c730a1d
institution Directory Open Access Journal
issn 2252-4940
language English
last_indexed 2024-03-09T08:09:29Z
publishDate 2017-06-01
publisher Diponegoro University
record_format Article
series International Journal of Renewable Energy Development
spelling doaj.art-6d5f7a742f1b4a409eeff8ae2c730a1d2023-12-02T23:27:28ZengDiponegoro UniversityInternational Journal of Renewable Energy Development2252-49402017-06-016218119110.14710/ijred.6.2.181-19111485Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, IndiaKamaljyoti Talukdar0Bineswar Brahma Engineering College,Kokrajhar-783370,Assam, IndiaThe present work consists of the modeling and analysis of solar photovoltaic panels integrated with electrolyzer bank and Polymer Electrolyte Membrane (PEM) fuel cell stacks for running different appliances of a hospital located in Kolkata for different climatic conditions. Electric power is generated by an array of solar photovoltaic modules. Excess energy after meeting the requirements of the hospital during peak sunshine hours is supplied to an electrolyzer bank to generate hydrogen gas, which is consumed by the PEM fuel cell stack to support the power requirement during the energy deficit hours. The study reveals that 875 solar photovoltaic modules in parallel each having 2 modules in series of Central Electronics Limited Make PM 150 with a 178.537 kW electrolyzer and 27 PEM fuel cell stacks, each of 382.372 W, can support the energy requirement of a 200 lights (100 W each), 4 pumps (2 kW each), 120 fans(65 W each) and 5 refrigerators (2 kW each)system operated for 16 hours, 2 hours,15 hours and 24 hours respectively. 123 solar photovoltaic modules in parallel each having 2 modules in series of Central Electronics Limited Make PM 150 is needed to run the gas compressor for storing hydrogen in the cylinder during sunshine hours.  Article History: Received Feb 5th 2017; Received in revised form June 2nd 2017; Accepted June 28th 2017; Available online How to Cite This Article: Talukdar, K. (2017). Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata,India. International Journal of Renewable Energy Development, 6(2), 181-191. https://dx.doi.org/10.14710/ijred.6.2.181-191https://ijred.cbiore.id/index.php/ijred/article/view/14814central electronics limited, electrolyzer, pem, pm 150, solar photovoltaic
spellingShingle Kamaljyoti Talukdar
Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India
International Journal of Renewable Energy Development
central electronics limited, electrolyzer, pem, pm 150, solar photovoltaic
title Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India
title_full Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India
title_fullStr Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India
title_full_unstemmed Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India
title_short Modeling and Analysis of Solar Photovoltaic Assisted Electrolyzer-Polymer Electrolyte Membrane Fuel Cell For Running a Hospital in Remote Area in Kolkata, India
title_sort modeling and analysis of solar photovoltaic assisted electrolyzer polymer electrolyte membrane fuel cell for running a hospital in remote area in kolkata india
topic central electronics limited, electrolyzer, pem, pm 150, solar photovoltaic
url https://ijred.cbiore.id/index.php/ijred/article/view/14814
work_keys_str_mv AT kamaljyotitalukdar modelingandanalysisofsolarphotovoltaicassistedelectrolyzerpolymerelectrolytemembranefuelcellforrunningahospitalinremoteareainkolkataindia