Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability

This article proposes a fault ride through (FRT) technique for a high-order virtual synchronous generator (VSG) that adjusts its virtual armature resistance. When a fault is detected by a dedicated algorithm, the proposed control adjusts the resistance parameter accordingly. The main contribution of...

Full description

Bibliographic Details
Main Authors: Daniel Carletti, Thiago Amorim, Lucas Encarnação
Format: Article
Language:English
Published: MDPI AG 2023-06-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/16/12/4680
_version_ 1797595037155983360
author Daniel Carletti
Thiago Amorim
Lucas Encarnação
author_facet Daniel Carletti
Thiago Amorim
Lucas Encarnação
author_sort Daniel Carletti
collection DOAJ
description This article proposes a fault ride through (FRT) technique for a high-order virtual synchronous generator (VSG) that adjusts its virtual armature resistance. When a fault is detected by a dedicated algorithm, the proposed control adjusts the resistance parameter accordingly. The main contribution of this article is to adjust the virtual resistance directly in the machine model to limit the current during faults, unlike other techniques proposed in the literature that add another control loop to produce the virtual impedance effects. To validate the effectiveness of the proposed control, a hardware-in-the-loop real-time simulation platform was adopted using a Typhoon HIL 402 device and a Texas Instruments F28379D digital controller. The results demonstrate that the control effectively limits the converter’s current while still contributing to raising the system’s critical clearing time (CCT) and improving transient stability. The proposed FRT strategy is validated in a three-phase fault scenario in which a 500 kVA–480 V converter’s peak fault current is reduced from 5 kA to 1.4 kA, depending on the resistance value adjusted. The transient stability is also analyzed in 30 different scenarios and the VSG support on the CCT is reduced by 23 ms on average. However, when compared to the baseline scenario without the VSG, the system still sees an increase in CCT with the current limiting control applied. Additionally, the control allows the VSG to smoothly transition to island mode in a scenario where the fault is cleared and the grid is disconnected by a protection system.
first_indexed 2024-03-11T02:31:41Z
format Article
id doaj.art-6d9fc545db9c473997e434345824e9d7
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-11T02:31:41Z
publishDate 2023-06-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-6d9fc545db9c473997e434345824e9d72023-11-18T10:12:41ZengMDPI AGEnergies1996-10732023-06-011612468010.3390/en16124680Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient StabilityDaniel Carletti0Thiago Amorim1Lucas Encarnação2Department of Electrical Engineering, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória 29075-910, BrazilDepartment of Electrical Engineering, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória 29075-910, BrazilDepartment of Electrical Engineering, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória 29075-910, BrazilThis article proposes a fault ride through (FRT) technique for a high-order virtual synchronous generator (VSG) that adjusts its virtual armature resistance. When a fault is detected by a dedicated algorithm, the proposed control adjusts the resistance parameter accordingly. The main contribution of this article is to adjust the virtual resistance directly in the machine model to limit the current during faults, unlike other techniques proposed in the literature that add another control loop to produce the virtual impedance effects. To validate the effectiveness of the proposed control, a hardware-in-the-loop real-time simulation platform was adopted using a Typhoon HIL 402 device and a Texas Instruments F28379D digital controller. The results demonstrate that the control effectively limits the converter’s current while still contributing to raising the system’s critical clearing time (CCT) and improving transient stability. The proposed FRT strategy is validated in a three-phase fault scenario in which a 500 kVA–480 V converter’s peak fault current is reduced from 5 kA to 1.4 kA, depending on the resistance value adjusted. The transient stability is also analyzed in 30 different scenarios and the VSG support on the CCT is reduced by 23 ms on average. However, when compared to the baseline scenario without the VSG, the system still sees an increase in CCT with the current limiting control applied. Additionally, the control allows the VSG to smoothly transition to island mode in a scenario where the fault is cleared and the grid is disconnected by a protection system.https://www.mdpi.com/1996-1073/16/12/4680fault ride throughgrid-forming converterpower system stabilitytransient stabilityvirtual synchronous generator
spellingShingle Daniel Carletti
Thiago Amorim
Lucas Encarnação
Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability
Energies
fault ride through
grid-forming converter
power system stability
transient stability
virtual synchronous generator
title Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability
title_full Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability
title_fullStr Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability
title_full_unstemmed Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability
title_short Virtual Armature Resistance-Based Control for Fault Current Limiting in a High-Order VSG and the Impact on Its Transient Stability
title_sort virtual armature resistance based control for fault current limiting in a high order vsg and the impact on its transient stability
topic fault ride through
grid-forming converter
power system stability
transient stability
virtual synchronous generator
url https://www.mdpi.com/1996-1073/16/12/4680
work_keys_str_mv AT danielcarletti virtualarmatureresistancebasedcontrolforfaultcurrentlimitinginahighordervsgandtheimpactonitstransientstability
AT thiagoamorim virtualarmatureresistancebasedcontrolforfaultcurrentlimitinginahighordervsgandtheimpactonitstransientstability
AT lucasencarnacao virtualarmatureresistancebasedcontrolforfaultcurrentlimitinginahighordervsgandtheimpactonitstransientstability