Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model

Category: Hindfoot Introduction/Purpose: Surgical reconstruction for flexible acquired flatfoot deformity from posterior tibial tendon dysfunction has been described and often includes a medial displacing calcaneal osteotomy (MDCO), Flexor digitorum longus (FDL) transfer, and possible spring ligamen...

Full description

Bibliographic Details
Main Authors: Michael Aynardi MD, Kaitlin Saloky BS, Paul Juliano MD, Gregory Lewis PhD
Format: Article
Language:English
Published: SAGE Publishing 2018-09-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011418S00147
_version_ 1819113701561597952
author Michael Aynardi MD
Kaitlin Saloky BS
Paul Juliano MD
Gregory Lewis PhD
author_facet Michael Aynardi MD
Kaitlin Saloky BS
Paul Juliano MD
Gregory Lewis PhD
author_sort Michael Aynardi MD
collection DOAJ
description Category: Hindfoot Introduction/Purpose: Surgical reconstruction for flexible acquired flatfoot deformity from posterior tibial tendon dysfunction has been described and often includes a medial displacing calcaneal osteotomy (MDCO), Flexor digitorum longus (FDL) transfer, and possible spring ligament repair. However, the spring ligament is often attenuated leaving surgeons with few options for robust repair. Meanwhile, the Internal Brace (Arthrex, Naples, Florida) has been reported in a patient series as an excellent adjunct for spring ligament augmentation for the treatment of flatfoot correction with good clinical results. However, there are no biomechanical studies, which evaluate its safety or efficacy. The aim of this study is to perform a biomechanical comparison of spring ligament repair with Internal Brace augmentation to controls undergoing reconstruction of a flatfoot model. Methods: 4 paired (8 total), below the knee, cadaveric specimens, age 45.3 years (range; 30-60), without pre-existing foot deformity were utilized. Flatfoot model was achieved as described in the literature. Surgical reconstruction included MDCO (7.5 mm calcaneal plate), a spring ligament repair reefing (2-0 fiber wire suture), and an FDL transfer through a navicular bone tunnel with interference fixation via a biotenodesis screw (Arthrex, Naples, Florida). The experimental group received spring ligament augmentation with an internal brace as described by the manufacturer’s specifications. After potting, specimens were loaded statically to measure contact pressures and flatfoot correction. Achilles was tensioned to 350 N and cyclic loading was performed in a stepwise fashion after preconditioning. Loading occurred at 1 Hertz for 100 cycles, increasing at 100 N intervals to 1800 N. Tekscan contact pressures, radiography, and digitized measurements were repeated. Spring ligament repair site was evaluated and failures were recorded. Results: There was a statistically significant difference under cyclic loading of the internal brace augmented repair compared to standard suture repair alone (p=0.001). There were no failures of the internal brace device. Control spring ligament repair failed via suture cutout. There was 1 catastrophic specimen failure through the tibio-talar joint in each group (1000 N control; 1800 N experimental). The average change in talometatarsal angle was not statistically significant between the control (4.31±2.82) and the internal brace (4.06±2.74) (p=0.66) after loading. There was no difference in the change of peak intra-articular contact pressure at the talonavicular joint between flatfoot model and surgical correction when comparing the internal brace reconstruction (1478.8±306.6 pKa) and controls (1816.5 ±436.7pKa) (p=0.79). Conclusion: The use of the Internal Brace device to augment spring ligament reefing repair appears biomechanically safe and effective under cyclic specimen loading in a pilot, cadaveric flatfoot reconstruction model. Furthermore, it does not appear to alter intra-articular talonavicular joint contact pressures.
first_indexed 2024-12-22T04:33:35Z
format Article
id doaj.art-6db55f994e7241eda39f4acaeb8ad321
institution Directory Open Access Journal
issn 2473-0114
language English
last_indexed 2024-12-22T04:33:35Z
publishDate 2018-09-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj.art-6db55f994e7241eda39f4acaeb8ad3212022-12-21T18:38:57ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142018-09-01310.1177/2473011418S00147Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot ModelMichael Aynardi MDKaitlin Saloky BSPaul Juliano MDGregory Lewis PhDCategory: Hindfoot Introduction/Purpose: Surgical reconstruction for flexible acquired flatfoot deformity from posterior tibial tendon dysfunction has been described and often includes a medial displacing calcaneal osteotomy (MDCO), Flexor digitorum longus (FDL) transfer, and possible spring ligament repair. However, the spring ligament is often attenuated leaving surgeons with few options for robust repair. Meanwhile, the Internal Brace (Arthrex, Naples, Florida) has been reported in a patient series as an excellent adjunct for spring ligament augmentation for the treatment of flatfoot correction with good clinical results. However, there are no biomechanical studies, which evaluate its safety or efficacy. The aim of this study is to perform a biomechanical comparison of spring ligament repair with Internal Brace augmentation to controls undergoing reconstruction of a flatfoot model. Methods: 4 paired (8 total), below the knee, cadaveric specimens, age 45.3 years (range; 30-60), without pre-existing foot deformity were utilized. Flatfoot model was achieved as described in the literature. Surgical reconstruction included MDCO (7.5 mm calcaneal plate), a spring ligament repair reefing (2-0 fiber wire suture), and an FDL transfer through a navicular bone tunnel with interference fixation via a biotenodesis screw (Arthrex, Naples, Florida). The experimental group received spring ligament augmentation with an internal brace as described by the manufacturer’s specifications. After potting, specimens were loaded statically to measure contact pressures and flatfoot correction. Achilles was tensioned to 350 N and cyclic loading was performed in a stepwise fashion after preconditioning. Loading occurred at 1 Hertz for 100 cycles, increasing at 100 N intervals to 1800 N. Tekscan contact pressures, radiography, and digitized measurements were repeated. Spring ligament repair site was evaluated and failures were recorded. Results: There was a statistically significant difference under cyclic loading of the internal brace augmented repair compared to standard suture repair alone (p=0.001). There were no failures of the internal brace device. Control spring ligament repair failed via suture cutout. There was 1 catastrophic specimen failure through the tibio-talar joint in each group (1000 N control; 1800 N experimental). The average change in talometatarsal angle was not statistically significant between the control (4.31±2.82) and the internal brace (4.06±2.74) (p=0.66) after loading. There was no difference in the change of peak intra-articular contact pressure at the talonavicular joint between flatfoot model and surgical correction when comparing the internal brace reconstruction (1478.8±306.6 pKa) and controls (1816.5 ±436.7pKa) (p=0.79). Conclusion: The use of the Internal Brace device to augment spring ligament reefing repair appears biomechanically safe and effective under cyclic specimen loading in a pilot, cadaveric flatfoot reconstruction model. Furthermore, it does not appear to alter intra-articular talonavicular joint contact pressures.https://doi.org/10.1177/2473011418S00147
spellingShingle Michael Aynardi MD
Kaitlin Saloky BS
Paul Juliano MD
Gregory Lewis PhD
Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model
Foot & Ankle Orthopaedics
title Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model
title_full Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model
title_fullStr Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model
title_full_unstemmed Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model
title_short Pilot Biomechanical Evaluation of Spring Ligament Augmentation with the Internal Brace in a Cadaveric Flatfoot Model
title_sort pilot biomechanical evaluation of spring ligament augmentation with the internal brace in a cadaveric flatfoot model
url https://doi.org/10.1177/2473011418S00147
work_keys_str_mv AT michaelaynardimd pilotbiomechanicalevaluationofspringligamentaugmentationwiththeinternalbraceinacadavericflatfootmodel
AT kaitlinsalokybs pilotbiomechanicalevaluationofspringligamentaugmentationwiththeinternalbraceinacadavericflatfootmodel
AT pauljulianomd pilotbiomechanicalevaluationofspringligamentaugmentationwiththeinternalbraceinacadavericflatfootmodel
AT gregorylewisphd pilotbiomechanicalevaluationofspringligamentaugmentationwiththeinternalbraceinacadavericflatfootmodel