Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve

There are two basic methods to calibrate the hydrological model: (1) the trial and error procedure; (2) the automatic calibration. The problem in the calibration method is the determination of the initial value of the parameters. This poses a problem for beginner model users. This paper presents the...

Full description

Bibliographic Details
Main Authors: Nugroho Suryoputro, Suhardjono Suhardjono, Widandi Soetopo, Ery Suhartanto
Format: Article
Language:English
Published: Universitas Brawijaya 2019-10-01
Series:Civil and Environmental Science Journal
Subjects:
Online Access:https://civense.ub.ac.id/index.php/civense/article/view/45
_version_ 1818416612812783616
author Nugroho Suryoputro
Suhardjono Suhardjono
Widandi Soetopo
Ery Suhartanto
author_facet Nugroho Suryoputro
Suhardjono Suhardjono
Widandi Soetopo
Ery Suhartanto
author_sort Nugroho Suryoputro
collection DOAJ
description There are two basic methods to calibrate the hydrological model: (1) the trial and error procedure; (2) the automatic calibration. The problem in the calibration method is the determination of the initial value of the parameters. This poses a problem for beginner model users. This paper presents the calibration results of surface runoff parameters in the hydrological tank model using recursive digital filter method and the master recession curve. The results indicate that the Recursive Digital Filter as a surface runoff separation method can be used for the initial approach to calibrate the tank model parameters
first_indexed 2024-12-14T11:53:40Z
format Article
id doaj.art-6db9e39181464837830bd41f13eb9b59
institution Directory Open Access Journal
issn 2620-6218
language English
last_indexed 2024-12-14T11:53:40Z
publishDate 2019-10-01
publisher Universitas Brawijaya
record_format Article
series Civil and Environmental Science Journal
spelling doaj.art-6db9e39181464837830bd41f13eb9b592022-12-21T23:02:11ZengUniversitas BrawijayaCivil and Environmental Science Journal2620-62182019-10-012212813410.21776/ub.civense.2019.00202.623Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curveNugroho Suryoputro0Suhardjono Suhardjono1Widandi Soetopo2Ery Suhartanto3Civil Engineering Universitas Negeri MalangTeknik Pengairan Fakultas Teknik UNiversitas BrawijayaTeknik Pengairan Fakultas Teknik UNiversitas BrawijayaTeknik Pengairan Fakultas Teknik UNiversitas BrawijayaThere are two basic methods to calibrate the hydrological model: (1) the trial and error procedure; (2) the automatic calibration. The problem in the calibration method is the determination of the initial value of the parameters. This poses a problem for beginner model users. This paper presents the calibration results of surface runoff parameters in the hydrological tank model using recursive digital filter method and the master recession curve. The results indicate that the Recursive Digital Filter as a surface runoff separation method can be used for the initial approach to calibrate the tank model parametershttps://civense.ub.ac.id/index.php/civense/article/view/45calibrationhydrological tank modelrecursive digital filtermaster recession curve
spellingShingle Nugroho Suryoputro
Suhardjono Suhardjono
Widandi Soetopo
Ery Suhartanto
Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
Civil and Environmental Science Journal
calibration
hydrological tank model
recursive digital filter
master recession curve
title Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
title_full Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
title_fullStr Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
title_full_unstemmed Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
title_short Calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
title_sort calibration of surface runoff parameters with the hydrologic tank model using recursive digital filter and master recession curve
topic calibration
hydrological tank model
recursive digital filter
master recession curve
url https://civense.ub.ac.id/index.php/civense/article/view/45
work_keys_str_mv AT nugrohosuryoputro calibrationofsurfacerunoffparameterswiththehydrologictankmodelusingrecursivedigitalfilterandmasterrecessioncurve
AT suhardjonosuhardjono calibrationofsurfacerunoffparameterswiththehydrologictankmodelusingrecursivedigitalfilterandmasterrecessioncurve
AT widandisoetopo calibrationofsurfacerunoffparameterswiththehydrologictankmodelusingrecursivedigitalfilterandmasterrecessioncurve
AT erysuhartanto calibrationofsurfacerunoffparameterswiththehydrologictankmodelusingrecursivedigitalfilterandmasterrecessioncurve