Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers
Spur dikes and triangular-shaped vanes are structures that control the erosion of a river’s outer bend by the diversion of flow from there to its center. In this study, the erosion and sedimentation patterns around a spur dike and a triangular-shaped vane was investigated using an experimental model...
Main Authors: | , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Marvdasht Branch, Islamic Azad University
2016-02-01
|
Series: | مهندسی منابع آب |
Subjects: | |
Online Access: | https://wej.marvdasht.iau.ir/article_1752_9a481fb399eff846363cfaaf71ec4ea5.pdf |
_version_ | 1797359766383624192 |
---|---|
author | M. Bahrami Yarahmadi M. Shafai Bejestan |
author_facet | M. Bahrami Yarahmadi M. Shafai Bejestan |
author_sort | M. Bahrami Yarahmadi |
collection | DOAJ |
description | Spur dikes and triangular-shaped vanes are structures that control the erosion of a river’s outer bend by the diversion of flow from there to its center. In this study, the erosion and sedimentation patterns around a spur dike and a triangular-shaped vane was investigated using an experimental model with a 90-degree mild bend. The triangular-shaped vane and spur dike with an effective length of one-fifth of the width of the canal (14 cm) and under different hydraulic conditions (Froude numbers 0.194, 0.214, 0.233 and 0.253) were tested. In all tests, a single triangular-shaped vane with an angle of 30 degree to the upstream direction, and a spur dike with an angle of 90 degree were installed in the outer bank of a flume in a 72° position, where the maximum scour depth usually occurs. For all tests, flow depth was kept constant equal to 13 cm. Bed topography was measured at the end of each experiment and the geometry of scour hole and point bar were determined. The results show that the maximum scour depth of the spur dike structure was more than that of the triangular-shaped vane. The average of maximum scour depth of the triangular-shaped vane and spur dike were 0.55 and 1.0 times that of the structure effective length, respectively. In addition, the maximum scour depth distance from the outer bank with a triangular-shaped vane was more than of the spur dike. The average distance of the maximum scour depth of spur dike and triangular-shaped vane structures from the outer bank were1.0 and 1.4 times the effective length of the structure, respectively. The point bar distance from the outer bank the spur dike structure was more for the triangular-shaped vane. The average point bar distance from the outer bank for spur dike and triangular-shaped vane were 0.34 and 0.1 times of effective length of the structure, respectively. |
first_indexed | 2024-03-08T15:28:32Z |
format | Article |
id | doaj.art-6e13cdb48dce45519d423cd71d1350fa |
institution | Directory Open Access Journal |
issn | 2008-6377 2423-7191 |
language | fas |
last_indexed | 2024-03-08T15:28:32Z |
publishDate | 2016-02-01 |
publisher | Marvdasht Branch, Islamic Azad University |
record_format | Article |
series | مهندسی منابع آب |
spelling | doaj.art-6e13cdb48dce45519d423cd71d1350fa2024-01-10T08:07:46ZfasMarvdasht Branch, Islamic Azad Universityمهندسی منابع آب2008-63772423-71912016-02-0182731421752Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude NumbersM. Bahrami Yarahmadi0M. Shafai Bejestan1دانش آموخته دکتری سازههای آبی، دانشکده مهندسی علوم آب دانشگاه شهید چمران اهوازاستاد گروه سازههای آبی، دانشکده مهندسی علوم آب دانشگاه شهید چمران اهوازSpur dikes and triangular-shaped vanes are structures that control the erosion of a river’s outer bend by the diversion of flow from there to its center. In this study, the erosion and sedimentation patterns around a spur dike and a triangular-shaped vane was investigated using an experimental model with a 90-degree mild bend. The triangular-shaped vane and spur dike with an effective length of one-fifth of the width of the canal (14 cm) and under different hydraulic conditions (Froude numbers 0.194, 0.214, 0.233 and 0.253) were tested. In all tests, a single triangular-shaped vane with an angle of 30 degree to the upstream direction, and a spur dike with an angle of 90 degree were installed in the outer bank of a flume in a 72° position, where the maximum scour depth usually occurs. For all tests, flow depth was kept constant equal to 13 cm. Bed topography was measured at the end of each experiment and the geometry of scour hole and point bar were determined. The results show that the maximum scour depth of the spur dike structure was more than that of the triangular-shaped vane. The average of maximum scour depth of the triangular-shaped vane and spur dike were 0.55 and 1.0 times that of the structure effective length, respectively. In addition, the maximum scour depth distance from the outer bank with a triangular-shaped vane was more than of the spur dike. The average distance of the maximum scour depth of spur dike and triangular-shaped vane structures from the outer bank were1.0 and 1.4 times the effective length of the structure, respectively. The point bar distance from the outer bank the spur dike structure was more for the triangular-shaped vane. The average point bar distance from the outer bank for spur dike and triangular-shaped vane were 0.34 and 0.1 times of effective length of the structure, respectively.https://wej.marvdasht.iau.ir/article_1752_9a481fb399eff846363cfaaf71ec4ea5.pdfspur diketriangular-shaped vane90° mild bendscour and deposition |
spellingShingle | M. Bahrami Yarahmadi M. Shafai Bejestan Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers مهندسی منابع آب spur dike triangular-shaped vane 90° mild bend scour and deposition |
title | Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers |
title_full | Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers |
title_fullStr | Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers |
title_full_unstemmed | Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers |
title_short | Comparison of Erosion and Sedimentation Patterns Facilitated by a Spur Dike and a Triangular-Shaped Vane Structures in a 90° Mild Bend under the Influence of Different Froude Numbers |
title_sort | comparison of erosion and sedimentation patterns facilitated by a spur dike and a triangular shaped vane structures in a 90° mild bend under the influence of different froude numbers |
topic | spur dike triangular-shaped vane 90° mild bend scour and deposition |
url | https://wej.marvdasht.iau.ir/article_1752_9a481fb399eff846363cfaaf71ec4ea5.pdf |
work_keys_str_mv | AT mbahramiyarahmadi comparisonoferosionandsedimentationpatternsfacilitatedbyaspurdikeandatriangularshapedvanestructuresina90mildbendundertheinfluenceofdifferentfroudenumbers AT mshafaibejestan comparisonoferosionandsedimentationpatternsfacilitatedbyaspurdikeandatriangularshapedvanestructuresina90mildbendundertheinfluenceofdifferentfroudenumbers |