About the choice of the test method to clarify the actual working scheme of the beam

This article discusses the problem of determining the actual scheme of a precast reinforced concrete frame of a building when performing engineering surveys. The method of connecting precast reinforced concrete structures in industrial buildings with heavy equipment plays an important role in assess...

Full description

Bibliographic Details
Main Author: Perunov Aleksandr
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/68/e3sconf_itse2023_06019.pdf
_version_ 1797658643150143488
author Perunov Aleksandr
author_facet Perunov Aleksandr
author_sort Perunov Aleksandr
collection DOAJ
description This article discusses the problem of determining the actual scheme of a precast reinforced concrete frame of a building when performing engineering surveys. The method of connecting precast reinforced concrete structures in industrial buildings with heavy equipment plays an important role in assessing the stress state of building structures. It is not always possible to perform the opening of nodes in the conditions of existing production, since this requires stopping technological processes or dismantling equipment. The article discusses the possibilities of static and dynamic tests for the study of support units in precast reinforced concrete structures during engineering surveys. The possibilities of static and dynamic test methods are considered, as well as the advantages and disadvantages of these methods when evaluating support units in precast reinforced concrete structures of buildings and structures during surveys. As an example for the study, the case of determining the current structural scheme of a precast reinforced concrete floor using dynamic tests is considered. The article analyzes previous studies on the use of the dynamic method in determining the actual scheme of existing reinforced concrete structures of an industrial building. The results of theoretical studies and their comparison with experimental results are presented. The general conclusions based on the results of the study are formulated, and recommendations are given on the choice of a method of testing structures for cases of establishing a structural scheme of precast reinforced concrete crossbars in operated industrial buildings during survey work.
first_indexed 2024-03-11T18:02:13Z
format Article
id doaj.art-6e1aa9e24518435e82c7093eefb1cf3f
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-03-11T18:02:13Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-6e1aa9e24518435e82c7093eefb1cf3f2023-10-17T08:49:32ZengEDP SciencesE3S Web of Conferences2267-12422023-01-014310601910.1051/e3sconf/202343106019e3sconf_itse2023_06019About the choice of the test method to clarify the actual working scheme of the beamPerunov Aleksandr0Moscow State University of Civil EngineeringThis article discusses the problem of determining the actual scheme of a precast reinforced concrete frame of a building when performing engineering surveys. The method of connecting precast reinforced concrete structures in industrial buildings with heavy equipment plays an important role in assessing the stress state of building structures. It is not always possible to perform the opening of nodes in the conditions of existing production, since this requires stopping technological processes or dismantling equipment. The article discusses the possibilities of static and dynamic tests for the study of support units in precast reinforced concrete structures during engineering surveys. The possibilities of static and dynamic test methods are considered, as well as the advantages and disadvantages of these methods when evaluating support units in precast reinforced concrete structures of buildings and structures during surveys. As an example for the study, the case of determining the current structural scheme of a precast reinforced concrete floor using dynamic tests is considered. The article analyzes previous studies on the use of the dynamic method in determining the actual scheme of existing reinforced concrete structures of an industrial building. The results of theoretical studies and their comparison with experimental results are presented. The general conclusions based on the results of the study are formulated, and recommendations are given on the choice of a method of testing structures for cases of establishing a structural scheme of precast reinforced concrete crossbars in operated industrial buildings during survey work.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/68/e3sconf_itse2023_06019.pdf
spellingShingle Perunov Aleksandr
About the choice of the test method to clarify the actual working scheme of the beam
E3S Web of Conferences
title About the choice of the test method to clarify the actual working scheme of the beam
title_full About the choice of the test method to clarify the actual working scheme of the beam
title_fullStr About the choice of the test method to clarify the actual working scheme of the beam
title_full_unstemmed About the choice of the test method to clarify the actual working scheme of the beam
title_short About the choice of the test method to clarify the actual working scheme of the beam
title_sort about the choice of the test method to clarify the actual working scheme of the beam
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/68/e3sconf_itse2023_06019.pdf
work_keys_str_mv AT perunovaleksandr aboutthechoiceofthetestmethodtoclarifytheactualworkingschemeofthebeam