RESIDENTIAL BUILDING’S DEFORMATION ON PILE FOUNDATION

A considerably distinctive deformed five-storeyed three-section brick residential house erected over 40 years ago on driven prismatic piles combined by a strip grid foundation by a standardized project is under investigation. The geotechnical monitoring results of the building's technical condi...

Full description

Bibliographic Details
Main Authors: Yuriy Vynnykov, Sergiy Manzhalii
Format: Article
Language:English
Published: Poltava National Technical Yuri Kondratyuk University 2019-10-01
Series:Збірник наукових праць: Серія: Галузеве машинобудування, будівництво
Subjects:
Online Access:http://journals.nupp.edu.ua/znp/article/view/1899
Description
Summary:A considerably distinctive deformed five-storeyed three-section brick residential house erected over 40 years ago on driven prismatic piles combined by a strip grid foundation by a standardized project is under investigation. The geotechnical monitoring results of the building's technical condition are presented. Methods and results of the instrumental control analysis of the piles' actual length and visual evaluation of their integrity are presented. The causes of the foundations base's excess deformation were determined: the inability of the piles' tips to reach the designed mark; the piles' destruction during their immersion in dense sands; rupture of the primary thermal network, which led to "negative friction" effect on the piles' lateral surface, etc.